U-Line SUHBV124-SG01A User Manual & Service Manual

U-Line SUHBV124-SG01A User Manual & Service Manual

1 class 24” beverage center

Advertisement

Quick Links

USER GUIDE & SERVICE MANUAL
1 Class
UHBV124
24" Beverage Center

Advertisement

Table of Contents
loading

Summary of Contents for U-Line SUHBV124-SG01A

  • Page 1 USER GUIDE & SERVICE MANUAL 1 Class UHBV124 24” Beverage Center ● ●...
  • Page 2 USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Intro Troubleshooting Wire Diagram Safety Product Liability Safety and Warning Warranty Claims Disposal And Recycling Parts Ordering Replacement Parts Installation R600a Specifications Environmental Requirements System Diagnosis Guide Electrical Compressor Specifications Cutout & Product Dimensions...
  • Page 3: Product Information

    ® to preserve the right product, in the right place, at the right temperature. Since 2014, U-Line has been part of the Middleby family of brands. All products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce...
  • Page 7 USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout & Product Dimensions

    23 ⁄ ” Cutout & Product Dimensions (608 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit FRONT does not require additional air space for top, sides, or 34 ⁄ ” to 35 ⁄ ”...
  • Page 9: Side-By-Side Installation

    USER GUIDE u-line.com Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Tighten screws fully. Cutout width for a side-by-side installation is the cutout 4.
  • Page 10: Anti-Tip Bracket

    USER GUIDE u-line.com Anti-Tip Bracket Slide unit out so screws on top of unit are easily accessible. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
  • Page 11: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable.
  • Page 12: Grille Installation

    Align cabinet and grille holes and secure, but do not over tighten grille screws (1). Note: When installing next to a 15” wide U-Line product, use the supplied spacers behind the grille. The 24” grille will now be on the same plane as the 15”...
  • Page 13: Door Swing

    USER GUIDE u-line.com Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
  • Page 14: Hinge Cover

    USER GUIDE u-line.com Door Adjustments REVERSING THE DOOR Location of the unit may make it desirable to mount the HINGE COVER door on the opposite side of the cabinet. The hinge hardware will be removed and reinstalled on the Hinge cover included with the literature bag is optional.
  • Page 15 USER GUIDE u-line.com Remove door by tilting forward and lifting door off Install top hinge and door: bottom hinge. Retain shoulder washers; they will be reused. Top Hinge Insert arrow clips into holes Right Side Top Hinge Left Side Pivot...
  • Page 16: Free Standing Kit

    Free Standing Kit Te free standing kit is an optional accessory (ULAFREESTANDS), used when unit is freestanding - not built into a cabinet. Available at u-line.com. To install the kit: Remove grille (see GRILLE INSTALLATION section). Align front hole wit hole in shell accessory, hole in base, and hole in grille.
  • Page 17: First Use

    If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set point before loading.
  • Page 18: Control Operation

    USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and hold down for 5 seconds Unit will turn On or OFF Press and release to leave interior After 3 hours, factory default is restored; light will Leave interior light on light on for 3 hours;...
  • Page 19: Airflow And Product Loading

    ⁄ ” ⁄ ” (66 mm) (64mm) When determining capacities U-Line uses typical 12 oz. cans, 12 oz. bottles, 750 mL white wine and red wine bottles shown below. ⁄ ” ⁄ ”...
  • Page 20: Recommended Wine Storage

    Specially designed horizontal wine racks properly position the bottles so the wine remains in contact with the cork, which ensures the cork does not become dry. U-Line recommends arranging wine bottles as shown in the illustration below. Racks 1 and 2: NOTE: After stocking, allow unit to stabilize product temperatures for 24 hours.
  • Page 21: Interior Cleaning

    USER GUIDE u-line.com Cleaning To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendation. Stainless Models Stainless door panels and handles can discolor when INTERIOR CLEANING exposed to chlorine gas, pool chemicals, saltwater or Disconnect power to the unit.
  • Page 22 USER GUIDE u-line.com NOTICE The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. To defrost: 1.
  • Page 23: Cleaning Condenser

    USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
  • Page 24: Wine Rack Installation

    USER GUIDE u-line.com Wine Rack Installation To remove rack from the cabinet: Remove any bottles stored on the rack. Grasp the end of the rack and gently slide it out until it stops. Press the left rack release lever down. At the same time, lift the matching right rack release lever up.
  • Page 25: Extended Non-Use

    If the unit will be exposed to temperatures of 40°F (5°C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 414.354.0300. CAUTION Damage caused by freezing temperatures is not covered by the warranty.
  • Page 26: Troubleshooting Guide

    BEFORE CALLING FOR SERVICE • Condenser Fan: Air moving through a condenser may be heard. If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the • Automatic Defrost Drain Pan: Water may be heard function of the control.
  • Page 27: Checking Product Temperature

    USER GUIDE u-line.com u-line.com CHECKING PRODUCT TEMPERATURE Causes which affect the internal temperatures of the cabinet include: • Temperature setting. • Ambient temperature where installed. • Installation in direct sunlight or near a heat source. • The number of door openings and the time the door is open.
  • Page 28: Wire Diagram

    USER GUIDE u-line.com Wire Diagram Wire Diagram...
  • Page 29: Product Liability

    The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 30: Warranty Claims

    Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 31 USER GUIDE u-line.com Parts * NOT PICTURED SUHBV124-SG01A Item Description U-Line P/N ANTI TIP BRACKET W/SCREWS 80-54239-00 BACK PANEL, OUTDR 1C 80-55497-00 COMPRESSOR ELECTRICALS ONLY 80-54149-00 COMPRESSOR W/ELECTRICALS 80-54150-00 CONDENSER ASSEMBLY 80-54801-00 * NOT PICTURED CONDENSER FAN W/SCREWS 80-54014-00 SUHBV124-SG01A...
  • Page 32: Ordering Replacement Parts

    Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 33 Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
  • Page 34 USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
  • Page 35: Leak Detection

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
  • Page 36 USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
  • Page 37: System Diagnosis Guide

    USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
  • Page 38: Compressor Specifications

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Compressor Specifications OVERLOAD PROTECTOR STARTING RELAY DANGER Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury.
  • Page 39: Troubleshooting - Extended

    • Automatic Defrost Drain Pan: Water may be heard U-Line Corp, “Customer Care Facility” at +1.800.779.2547 dripping or running into the drain pan when the unit is for assistance. in the defrost cycle.
  • Page 40 USER GUIDE u-line.com TROUBLESHOOTING GUIDE Concern Potential Causes Action Not Cooling Compressor overheating Verify proper air flow through condenser. Is condenser clean? Confirm condenser fan operation. Compressor not operating Test overload and relay, replace as needed. Compressor operating - no cooling Refer to System Diagnosis Guide.
  • Page 41: Main Control

    USER GUIDE u-line.com MAIN CONTROL CAUTION The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose Precautions must be taken while working with the board for any suspected failures before attempting live electrical equipment.
  • Page 42 USER GUIDE u-line.com Control Operation-Service UI BUTTON LAYOUT Up Button -Increases temperature -Navigates through service menu -LED activated with button activation Down Button -Decreases temperature -Navigates through service menu -LED activated with button activation Light Button -Activates light for 3 hours on select models...
  • Page 43: Thermistor Failure

    USER GUIDE USER GUIDE u-line.com u-line.com Thermistors Thermistor Thermistor Resistance Data Thermistor Resistance Data Nominal Resistance Thermistors are used for various temperature readings. Temp (F) Temp (C) Thermistors are used for various temperature readings. (OHMS)* Thermistors provide reliable temperature readings using a...
  • Page 44 USER GUIDE u-line.com Defrost Outdoor units defrost every 12 hours of compressor runtime for 45 minutes. If you have verified that the unit does not have an ambient air leak, utilize the Control Operation - Service section and adjust unit to defrost...
  • Page 45: Remove Fan And Cover

    USER GUIDE u-line.com Remove Fan and Cover Remove insulating foam from refrigerant line pass- through hole as needed to gain clearance for fan plug. CONVECTION COOLING Remove internal shelving. This unit is equipped with an advanced convection cooling system. Convection cooling stabilizes cabinet temperature, Remove rear shelf clips, fronts can remain.
  • Page 46 USER GUIDE u-line.com 14. Remove and replace fan. Take special care to properly route fan wire. NOTICE Fan must be oriented to pull air in through lower evaporator cover vents and push air out at fan mounting location. 15. Installation is the reverse of removal.
  • Page 47 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.

This manual is also suitable for:

Uhbv1241 series

Table of Contents