Kasco VFX Operation & Maintenance Manual

Decorative aerator
Hide thumbs Also See for VFX:

Advertisement

Quick Links

MOVING WATER FORWARD, SINCE 1968
VFX
DECORATIVE
AERATOR
8400, 2.3, 5.1, 5.3
Operation &
Maintenance
Manual
3020379
ANSI/UL 778: 2016
Ed.6+R:22Feb2017
CSA C22.2 #108: 2014 Ed.5
Document number 884172
Document version 2021.2.0
800 Deere Rd. Prescott, WI 54021 | 715.262.4488 | sales@kascomarine.com | kascomarine.com
2HP-5HP VFX AERATOR MANUAL
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VFX and is the answer not in the manual?

Questions and answers

Summary of Contents for Kasco VFX

  • Page 1 8400, 2.3, 5.1, 5.3 Operation & Maintenance Manual 3020379 ANSI/UL 778: 2016 Ed.6+R:22Feb2017 CSA C22.2 #108: 2014 Ed.5 Document number 884172 Document version 2021.2.0 800 Deere Rd. Prescott, WI 54021 | 715.262.4488 | sales@kascomarine.com | kascomarine.com 2HP-5HP VFX AERATOR MANUAL...
  • Page 2: Table Of Contents

    Unit Specifications & Pattern Size ..................3 Tools & Supplies Needed .......................3 Parts Included .........................4 Unit Installation Instructions ....................9 Maintenance Recommendations ..................11 Troubleshooting Tips ......................12 Warranty ..........................13 Non-Warranty Repairs ......................14 Repair Contact Form ......................15 QUESTIONS? 715.262.4488 kascomarine.com | sales@kascomarine.com 2HP-5HP VFX AERATOR MANUAL...
  • Page 3: Safety First

    • Kasco Aerating Fountains are intended for use with a Listed control panel having a GFCI protected receptacle, or field wiring terminals and disconnect switch, or a timer with a disconnect for use with a GFCI receptacle. Control panels MUST be installed by a qualified electrician. Ground Fault Circuit Interrupters (GFCIs) should be tested upon each installation and every month thereafter to ensure proper operation.
  • Page 4: Unit Specifications & Pattern Size

    (4) #10 x 1’’ long or longer screws for mounting the control panel • 9/16’’ socket with extension and ratchet • 7/16’’ socket and ratchet or combination wrench • (3) 12’’ pieces of 1’’ galvanized pipe for weighting ropes (optional) 7/16’’combination 9/16’’ socket wrench (extension not shown) 2HP-5HP VFX AERATOR MANUAL...
  • Page 5: Parts Included

    Back to Contents PARTS INCLUDED Description Qty Part # 3/8-16 hex head screw 820093 3/8” lock washer 566230 VFX upper float screen 284165 Float, single phase See table below L-bracket, large VFX 284170 1/4” lock washer 840537 1/4”-20 x 1” hex head screw...
  • Page 6 L-brackets, and the dedicated power cord channel on the underside of the float is near the cord connection on the unit assembly. Dedicated power cord channel 2HP-5HP VFX AERATOR MANUAL...
  • Page 7 4. On the underside of the float, line up the (3) bottom screen clips (J) and start threading in the (3) 3/8”-16 x 1/2’’ serrated hex head screws (K), but do not tighten down at this time. Be sure the clips can slide back and forth freely. Allow movement 2HP-5HP VFX AERATOR MANUAL...
  • Page 8 10. Lift the unit and slide the bottom float screen (I) with the mesh over the can and up to the bottom of the float, allowing the unit power cord to exit between them in the dedicated channel. Dedicated power cord channel 2HP-5HP VFX AERATOR MANUAL...
  • Page 9 If your Kasco cord comes with a strain relief kit at- tached, attach the available link to the float-side knot in the mooring rope, as pictured here.
  • Page 10: Unit Installation Instructions

    Low water level High water level After unit is installed in the water, connect the power cord to a properly installed Kasco control panel (C-85, C-95, etc.) with built-in ground fault protection according to the instructions and electrical schematics in- cluded with the panel.
  • Page 11 Keep clear of the propeller while verifying rotation. Air will be blowing out (up) of the pump chamber when rotating in the correct direction. If a Kasco 3-phase panel is supplied, follow the instructions included with the panel in addition to the steps below.
  • Page 12: Maintenance Recommendations

    SACRIFICIAL ANODE: A sacrificial anode is supplied on the shaft of all VFX Model aerators for protection from corrosion and electrolysis. The anode should be updated/replaced if reduced to half the original size or if white in color.
  • Page 13: Troubleshooting Tips

    “My aerator turns itself off and back on without the timer and without tripping the GFI breaker.” (single phase units only) Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats. Once the unit has cooled down, it will start back up. If you are noticing these symptoms, the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor.
  • Page 14: Warranty

    (excluding ropes, power cord, and propeller). The Kasco Marine, Inc. obligation under this warranty is limited to replacing or repairing free of charge any defective part within the warranty period from the date of shipment. Customer shall pay shipping charges for returning the unit to Kasco or an Autho- rized Repair Center.
  • Page 15: Non-Warranty Repairs

    Please ship according to the instructions on the previous provided. Kasco Marine does estimates on repairs at the request of the customer. The request for estimate should be included in the letter that accompanies the returned unit and must include a daytime phone number and/ or e-mail address.
  • Page 16: Repair Contact Form

    Back to Contents REPAIR CONTACT FORM • Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention. Kasco Marine • Unit should be cleaned before shipping. 800 Deere Road • Kasco is NOT responsible for shipping damage accrued in Prescott, WI 54021 return shipment.