LG DLE3 0 Series Owner's Manual page 29

Table of Contents

Advertisement

Available languages

Available languages

Three-Wire Power Cord
• A 3-wire connection is NOT permitted
on new construction after January 1,
1996.
• A UL-listed strain relief is required.
• Use a 30-amp, 240-volt, 3-wire,
UL-listed power cord with #10 AWG-
minimum copper conductor and closed
loop or forked terminals with upturned
ends.
1
Remove the terminal block access cover on the
upper back of the dryer.
2
Install a UL-listed strain relief into the power
cord through-hole.
3
Thread a 30-amp, 240-volt, 3-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
UL-Listed 3-Wire Power
UL-Listed 3-Wire Power
Cord
Cord
4
Attach the two hot leads (black and red) of the
power cord to the outer terminal block screws.
5
Attach the neutral (white) wire to the center
terminal block screw.
6
Connect the external ground (if required by local
codes) to the green ground screw.
7
Tighten all screws securely.
8
Ground Screw
Ground Screw
White Wire from Dryer
White Wire from Dryer
harness
harness
Terminal Block
Terminal Block
UL-Listed Strain
UL-Listed Strain
Relief
Relief
INSTALLATION
Reinstall the terminal block access cover.
Hot (Black)
Hot (Black)
Neutral (White)
Neutral (White)
External Ground Wire (If
External Ground Wire (If
required by local codes)
required by local codes)
29
Hot (Red)
Hot (Red)

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dlg3 1 seriesDlex 00 seriesDlgx 01 series

Table of Contents