Mustee DURAWALL 732 Installation Instructions Manual

Fiberglass showerwall

Advertisement

MUSTEE
IMPORTANT:
Before you assemble and install your
to prepare the rough-in area, determine which side wall will have the shower head & control valve and if unit will be
equipped with a shower door or curtain. Please read instructions before proceeding with installation. The shower
wall unit does not require any trimming or cutting for normal installations.
Quality Plumbing Products
E.L. MUSTEE & SONS, INC.
5431 West 164th Street • Brook Park, Ohio 44142
FITS MUSTEE 32 X 32 SHOWER RECEPTOR
SEE BACK PAGE FOR SHOWER DOOR (ENCLOSURE) LISTING
MODEL 732
FIBERGLASS
SHOWERWALL
three-piece Molded Fiberglass Shower Wall unit you will have
Sl-164 (5•06 )

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DURAWALL 732 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mustee DURAWALL 732

  • Page 1 MUSTEE FIBERGLASS SHOWERWALL FITS MUSTEE 32 X 32 SHOWER RECEPTOR SEE BACK PAGE FOR SHOWER DOOR (ENCLOSURE) LISTING IMPORTANT: MODEL 732 Before you assemble and install your three-piece Molded Fiberglass Shower Wall unit you will have to prepare the rough-in area, determine which side wall will have the shower head & control valve and if unit will be equipped with a shower door or curtain.
  • Page 2 TOOLS AND MATERIALS* See back cover page. ROUGH-IN FRAMING After you have determined where your MUSTEE SHOWERWALL is to be located you will have to construct the appropriate alcove. Be sure to plan your rough plumbing requirements (drain-venting-supply lines) at this time. Refer to “ROUGH-IN”...
  • Page 3 Place shower receptor directly on sub-floor or slab, level receptor in both directions — place level along top edge of tile flanges — do not use floor area which is tapered for water drainage. HINT: You may want to install shower receptor in a bed of gypsum cement or panel/floor adhesive for additional support.
  • Page 4 The Center and Side Panels have a mounting flange that is designed to accept standard “deck” screws, the position ing of the studs and bracing have been laid-out to give maximum support (horizontally and vertically) behind these flanges. The mounting flanges have pre-marked holes — to avoid cracking the flange, it is recommended that you pre-drill all of the holes with a 5/32”...
  • Page 5 SHOWER WALL ASSEMBLY The Side Panel has (3) three latches located on the edge of the blade that lock into corresponding slots in the Center Panel groove. Hold side panel approximately 1/2” (inch) above center panel. Align and insert latches into slots, lower side panel to lock in place —...
  • Page 6 48” max. 17-7/8” *Includes escutcheons, trim, etc. (EXAMPLE: Control valve with 6” diameter escutcheon should have a max. centerline height of 45” from sub-floor.) E.L. MUSTEE & SONS, INC. 5431 West 164th Street • Brook Park, Ohio 44142 Sl-164 (5•06)