  • Page 1 Leonardo Off-Grid 4kW-3000-48 GE Manuale utente User manual...
  • Page 3 • Efficienza inverter 95% • Efficienza regolatore di carica FV 97,2% Il Leonardo Off-Grid 4kW/3000/48 GE è stato concepito e appositamente • Contatto per accensione automatica sviluppato per la produzione e lo stoccaggio di energia domestico; abbinato a moduli fotovoltaici e a batterie di accumulo provvede all’alimentazione del Gruppo Elettrogeno della abitazione fino al suo completo auto-sostentamento.
  • Page 4 Leonardo Off-Grid 4kW/3000/48 GE Manuale utente Istruzioni di sicurezza Pericolo di esplosione a causa di scintille Pericolo di folgorazione ATTENZIONE: non sollevare oggetti pesanti senza assistenza Generale • Si consiglia di leggere attentamente questo manuale prima di installare e utilizzare il prodotto.
  • Page 5 Manuale utente FUNZIONAMENTO DEL LEONARDO OFF-GRID 4kW/3000/48 GE Il Leonardo Off-Grid 4kW/3000/48 GE è progettato per ottenere un risparmio energetico diretto tramite l’utilizzo di energia fotovoltaica ed altre fonti rinnovabili; l'impianto fotovoltaico viene gestito tramite il regolatore di carica con n.4 ingressi MPPT indipendenti;...
  • Page 6 Il Leonardo Off-Grid possiede l'uscita AC-OUT dedicata alla connessione delle utenze domestiche, alimentate anche in caso di avaria o assenza del gruppo elettrogeno. L' Energy Manager, interno al Leonardo Off-Grid provvede al controllo ed alla gestione del sistema, inoltre fornisce una visualizzazione rapida dello stato di funzionamento del sistema.
  • Page 7: Schema Di Collegamento

    Leonardo Off-Grid 4kW/3000/48 GE Manuale utente SCHEMA DI COLLEGAMENTO INVERTER DC/AC - Potenza continua 3000 VA - Potenza di sovraccarico 2500W - Ingresso AC - Batteria 48Vdc DATA LOGGER OPZIONALE - Energia prodotta - Energia prelevata CAMPO FV - Indice di indipendenza energetica...
  • Page 8 PROTEZIONI ESTERNE Protezioni lato Corrente Alternata Il Leonardo Off-Grid 4kW/3000/48 GE è dotato di una linea di uscita in corrente alternata AC-OUT ed una linea di ingresso in corrente alternata AC-IN. Essendo l'apparecchio dotato di collegamento a terra del conduttore NEUTRO - sistema TT, la linea di uscita in corrente alternata AC-OUT può...
  • Page 9 SEZIONE REGOLATORI DI CARICA FOTOVOLTAICA Il Leonardo Off-Grid 4kW/3000/48 GE è dotato di regolatore di carica FV con 4 ingressi MPPT indipendenti: è un regolatore di carica da moduli fotovoltaici per batterie elettrochimiche al piombo di tipo OPzV o OPzS.
  • Page 10 Manuale utente SEGNALAZIONI ESTERNE Sul lato laterale del Leonardo Off-Grid 4kW/3000/48 GE sono presenti le segnalazioni di funzionamento dell’inverter: Inverter Mode e Bypass Mode, lo stato di carica della batteria, la potenza assorbita dal carico, lo stato del carica da fotovoltaico e la presenza della rete AC dal gruppo elettrogeno.
  • Page 11 Leonardo Off-Grid 4kW/3000/48 GE Manuale utente LOGICA DI FUNZIONAMENTO Home Consumption PV Production Genset Power Battery Power Fig.10 Logica di funzionamento Tabella Stato di carica e potenza di uscita Stato di carica SOC livello 4, l'energia effettivamente stoccata in batteria si...
  • Page 12: Installazione E Cablaggio

    RESET presente alla base dell'apparecchio (Fig. 12). INSTALLAZIONE E CABLAGGIO a) Installare il Leonardo Off-Grid 4kW/3000/48 GE in un luogo asciutto ed adeguatamente arieggiato, fissato su di una superficie non infiammabile e posizionato in modo da lasciare uno spazio privo di ostacoli di almeno 10cm nell’intorno del dispositivo che ne permette il raffreddamento per convezione forzata dell’aria.
  • Page 13 Leonardo Off-Grid 4kW/3000/48 GE Manuale utente 5. collegare ingresso AC-IN su connessione AC Input tramite connettori AC plug and play tipo RST (se presente il gruppo elettrogeno); 6. collegare uscita AC-OUT su connessione AC Output tramite connettori AC plug and play tipo RST 7.
  • Page 14 1. contatto attivo per una tensione inferiore ai 45V (o 22,5V per 1kW/1500/24), entro 10 secondi; 2. il dispositivo Leonardo Off-Grid accetta all'ingresso AC INPUT la connessione di uscita 230Vac dal gruppo elettrogeno con corrente potenza di ricarica massima pari a: 0,75kW e corrente di carica 30A@24V per il...
  • Page 15 AVVIAMENTO E COLLAUDO DELL’IMPIANTO Appena realizzati i collegamenti come in Fig.12 è necessario procedere avviamento e collaudo del sistema: 1) verificare l’accensione del Leonardo Off-Grid 4kW/3000/48 GE al termine del collegamento dei cavi sui morsetti della batteria ed attivazione dell'interruttore di sezionamento batteria;...
  • Page 16 Leonardo Off-Grid 4kW/3000/48 SL Manuale utente Schema Unifilare dell'impianto trifase 9kW. Fig.14 Schema Unifilare dell'impianto trifase 9Kw...
  • Page 17 Leonardo Off-Grid 4kW/3000/48 SL Manuale utente Impianto Trifase tot. 18kW: Fase L1  n.1 Master + n.1 Slave - Fase L2  n.2 Slave - Fase L3  n.2 Slave INVERTER MASTER L1 INVERTER SLAVE L2 INVERTER SLAVE L3 A - Plug Datalogger...
  • Page 18 Leonardo Off-Grid 4kW/3000/48 Manuale utente CARATTERISTICHE MECCANICHE E PESO Leonardo Off-Grid 4kW/3000/48 GE = 25 kg Fig.17 Caratteristiche meccaniche...
  • Page 19: Caratteristiche Elettriche

    Leonardo Off-Grid 4kW/3000/48 Manuale utente CARATTERISTICHE ELETTRICHE Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid 1kW / 1500 / 24 GE 4kW / 3000 / 48 GE 4kW / 5000 / 48 GE 8kW / 8000 / 48 GE Potenza di uscita Pout 1.500VA 3.000W...
  • Page 20: Smaltimento Dei Rifiuti

    Il prodotto difettoso dovrà essere rispedito alla Western CO. srl o a società delegata dalla Western CO. srl a fare assistenza sul prodotto, a spese del cliente, assieme ad una copia della fattura di vendita, sia per la riparazione che la sostituzione garantita.
  • Page 21 • Lead Batteries for cyclic use OPzS, house until it is fully self-sustaining. OPzV Leonardo Off-Grid 4kW/3000/48 GE makes it easy and immediate the use • Low battery protection of energy produced by photovoltaic modules, for the supply of domestic consumptions, with the possibility of using a genset (back-up) in case of •...
  • Page 22 Leonardo Off-Grid 4kW/3000/48 GE User Manual Safety instructions Danger of explosion from sparking Danger of electric shock WARNING: do not lift heavy objects unassisted. In general • Read the installation instructions before commencing installation activities. • The product installation and maintenance must be performed only by qualified personnel.
  • Page 23 User Manual LEONARDO OFF-GRID 4kW / 3000/48 GE WORKING PRINCIPLES Leonardo Off-Grid 4kW/3000/48 GE is designed to achieve direct energy savings through the use of photovoltaic energy and other renewable sources; the photovoltaic system is managed by the charge controller with 4 independent MPPT inputs;...
  • Page 24: Internal Diagram

    Pic.3 Internal diagram The Leonardo Off-Grid provides an internal diagram such as that shown in the upper picture, this configuration provides that the device has an AC-IN input connection from the genset, if available for housing, with a nominal power of at least 3000VA.
  • Page 25: Connection Diagram

    Leonardo Off-Grid 4kW/3000/48 GE User manual CONNECTION DIAGRAM DC / AC INVERTER - Continuous Power 3000 VA - 2500W overload power - AC input - 48Vdc Battery OPTIONAL DATA LOGGER - Produced energy - Drawn energy - Index of Energy independence...
  • Page 26: External Protection

    EXTERNAL PROTECTION Protections for Alternating Current side Leonardo Off-Grid 4kW/3000/48 GE is equipped with an AC-OUT alternating current output line and an AC-IN alternating current input line. Since the device has a conductor connected to the NEUTRAL - TT system, the AC output line AC-OUT can be protected with a thermal-magnetic circuit breaker AC type, with nominal current In = 16A and differential current Id = 0.03 (usually...
  • Page 27 User Manual PHOTOVOLTAIC CHARGE CONTROLLER SECTION Leonardo Off-Grid 4kW / 3000/48 GE is equipped with PV charge controller with 4 independent MPPT inputs: is a charge controller for photovoltaic modules for lead electrochemical batteries of the OPzV or OPzS type.
  • Page 28: External Signals

    EXTERNAL SIGNALS On the lateral side of Leonardo Off-Grid 4kW/3000/48 GE there are the working reports of the inverter: Inverter Mode - By-pass Mode, the status of the battery charge, the power absorption of the load, the status of the photovoltaic charge and the presence of the AC grid in input.
  • Page 29: Operating Logic

    Leonardo Off-Grid 4kW/3000/48 GE User Manual OPERATING LOGIC Home Consumption PV Production Genset Power Battery Power Pic.10 Operating logic Charge status and output power table SOC charge status level 4, the actually stored energy in the battery is in an...
  • Page 30: Installation And Wiring

    INSTALLATION AND WIRING a) Install Leonardo Off-Grid 4kW/3000/48 GE in a dry and adequately ventilated place, fixed on a non-combustible surface and positioned in order to have a space free of obstacles of at least 10 cm around the device so to have the cooling by forced air convection.
  • Page 31 Leonardo Off-Grid 4kW/3000/48 GE User Manual 5. connect input AC-IN on AC Input connection through plug and play type RST AC connectors (if the genset is present); 6. connect AC-OUT output on AC Output connection via plug and play type RST AC connectors 7.
  • Page 32: Reset Button

    1. active contact for a voltage lower than 45V (or 22.5V for 1kW / 1500/24), within 10 seconds; 2. the Leonardo Off-Grid device accepts at the AC INPUT input the 230Vac output connection from the generating set with current maximum charging power equal to: 0.75kW and charging current 30A @ 24V for the 1kW/1500/24 GE model - 1.5kWp and charging current 30A @ 48V for model 4kW/3000/48...
  • Page 33: Possible Problems And Solutions

    As soon as the connections are made as in Pic.12 it is necessary to start and test the system: 1) check the switching on of the Leonardo Off-Grid 4kW/3000/48 GE at the end of the cable connection on the battery terminals and activation of the battery isolation switch;...
  • Page 34 Leonardo Off-Grid 4kW/3000/48 SL User manual Single-phase diagram of the 9kW three-phase system. Pic.14 Single line diagram of the 9Kw three-phase system...
  • Page 35 User Manual Leonardo Off-Grid 4kW/3000/48 SL Three Phase System tot. 18kW: Phase L1  n.1 Master + n.1 Slave - Phase L2 No.  2 Slave - Phase L3 No.  2 Slave INVERTER MASTER L1 INVERTER SLAVE L2 INVERTER SLAVE L3...
  • Page 36 Leonardo Off-Grid 4kW/3000/48 GE User Manual MECHANICAL FEATURES AND WEIGHT Leonardo Off-Grid 4kW / 3000/48 GE = 25 kg Pic.17 Mechanical features...
  • Page 37: Electrical Features

    Leonardo Off-Grid 4kW/3000/48 GE User Manual ELECTRICAL FEATURES Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid Leonardo Off-Grid 1kW / 1500/24 GE 4kW / 3000/48 GE 4kW / 5000/48 GE 8kW / 8000/48 GE Output power Pout 1,500VA 3,000W 3,000VA 6,000W 5,000VA...
  • Page 38: Warranty

    The defective product must be returned to Western CO. srl or to a company delegated by Western CO. srl to provide assistance on the product, at the expense of the customer, together with a copy of the sales invoice, both for repair and guaranteed replacement.
  • Page 39 Questo documento è di proprietà di WESTERN CO. Srl - Tutti i diritti sono riservati - La riproduzione e l'uso delle informazioni contenute nel presente documento sono vietati senza il consenso scritto di WESTERN CO. Srl. This document is the property of WESTERN CO. Srl - All rights are reserved - Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO.