Summary of Contents for Western Co Leonardo Off-Grid GE Py

  • Page 1 Leonardo Off-Grid GE Py Lithium version Compatible with: Manuale utente User manual...
  • Page 3 Gruppo Elettrogeno della abitazione fino al suo completo auto-sostentamento. • Interruttore di sezionamento batteria Il Leonardo Off-Grid GE Py rende facile ed immediato l’utilizzo di energia • Tensione di batteria 48Vdc prodotta da moduli fotovoltaici, per l’alimentazione di utenze domestiche, con l’ausilio di un gruppo elettrogeno (back-up) in caso di ridotta energia...
  • Page 4 ATTENZIONE: non sollevare oggetti pesanti senza assistenza Generale La Western CO. declina ogni responsabilità nel caso non vengano rispettate le norme per una corretta installazione e non risponde degli impianti a monte o a valle dell’apparecchiatura da essa fornita. È assolutamente vietato effettuare modifiche all’apparecchiatura. Qualsiasi modifica, manipolazione o alterazione non espressamente concordata con il costruttore, sia essa di natura software oppure hardware al prodotto, comporta l’immediato decadimento della garanzia.
  • Page 5 Qualora si riscontrino difetti o deterioramenti sospendere le operazioni e interpellare il vettore, nonché informare tempestivamente l’assistenza Western CO. • In caso di reso al produttore il materiale va adeguatamente imballato e protetto. La Western CO. si riserva di valutare le condizioni del prodotto e di garanzia in caso di danneggiamento da imballo improprio.
  • Page 6 Leonardo Off-Grid GE Py / SL Manuale utente Disimballo e verifiche Rammentiamo che gli elementi dell’imballo (cartone, cellophane, punti metallici, nastro adesivo, regge, ecc...) possono tagliare e/o ferire, se non maneggiati con cura. Essi vanno rimossi con opportuni mezzi e non lasciati in balia di persone non responsabili (es.
  • Page 7: Table Of Contents

    Leonardo Off-Grid GE Py / SL Manuale utente Indice 1. FUNZIONAMENTO DEL LEONARDO OFF-GRID GE PY ..................6 1.1. Logica Di Funzionamento ..........................7 1.2. Schema Interno ............................7 2. INSTALLAZIONE ..............................8 2.1. Installazione Meccanica ..........................8 2.2. Connessioni ..............................9 2.2.1.
  • Page 8: Funzionamento Del Leonardo Off-Grid Ge Py

    Manuale utente 1. FUNZIONAMENTO DEL LEONARDO OFF-GRID GE PY Il Leonardo Off-Grid GE Py è progettato per ottenere un risparmio energetico diretto tramite l’utilizzo di energia fotovoltaica ed altre fonti rinnovabili; l'impianto fotovoltaico viene gestito tramite il regolatore di carica con n.4 ingressi MPPT indipendenti;...
  • Page 9: Logica Di Funzionamento

    AC-IN dal gruppo elettrogeno, se disponibile per l'abitazione, con potenza pari ad almeno la potenza dell’inverter Leonardo Off-Grid GE Py. Il Leonardo Off-Grid possiede l'uscita AC-OUT dedicata alla connessione delle utenze domestiche, alimentate anche in caso di avaria o assenza del gruppo elettrogeno.
  • Page 10: Installazione

    L'installazione va effettuata con ad apparecchiature spente e non alimentate. 2.1. Installazione Meccanica a) Installare il Leonardo Off-Grid GE Py in un luogo asciutto ed adeguatamente arieggiato, fissato su di una superficie non infiammabile e posizionato in modo da lasciare uno spazio privo di ostacoli di almeno 20cm nell’intorno del dispositivo che ne permette il raffreddamento per convezione forzata dell’aria.
  • Page 11: Connessioni

    * Attenzione: la corrente di ricarica massima è al netto dei carichi applicati e al netto dell’efficienza della macchina. 2.2.1.1. Protezioni lato Corrente Alternata Il Leonardo Off-Grid GE Py è dotato di una linea di uscita in corrente alternata AC-OUT ed una linea di ingresso in corrente alternata AC-IN.
  • Page 12: Collegamento Lato Dc

    Leonardo Off-Grid GE Py / SL Manuale utente 2.2.2. Collegamento lato DC 2.2.2.1. Batterie Pylontech Collegare i morsetti rapidi dei cavi di potenza in dotazione: positivo (+, arancio), negativo (-, nero) alla batteria e il cavo di comunicazione CAN (incluso in dotazione), come in Fig.6.
  • Page 13: Moduli Fotovoltaici

    Leonardo Off-Grid GE Py / SL Manuale utente 2.2.2.2. Moduli Fotovoltaici Nella scelta della configurazione della stringa di moduli da impiegare nel sistema è necessario attenersi strettamente a quanto indicato nella seguente tabella. Caratteristiche moduli PV Potenza per canale 1000 W (max 1150 Wp).
  • Page 14: Segnalazioni Esterne Energy Manager

    8. collegare uscita AC-OUT su connessione AC Output tramite connettori AC plug and play tipo RST. N.B.: per spegnere correttamente il sistema seguire la precedente procedura a ritroso. 5. SEGNALAZIONI ESTERNE ENERGY MANAGER Sul lato laterale del Leonardo Off-Grid GE Py sono presenti le segnalazioni di funzionamento dell’inverter. Se acceso indica la presenza di tensione...
  • Page 15 Leonardo Off-Grid GE Py / SL Manuale utente Tabella segnalazione Stato di Carica batteria Stato di carica SOC livello 5, l'energia effettivamente stoccata in batteria si trova in un intervallo compreso tra 80% - 100% della propria capacità nominale Stato di carica SOC livello 4, l'energia effettivamente stoccata in batteria si trova in un intervallo compreso tra 60% - 80% della propria capacità...
  • Page 16: Collaudo Sistema

    7. APPLICAZIONI TRIFASE O PARALLELO CON VERSIONE SLAVE SL Leonardo Off-Grid GE Py, versione Master per applicazioni con ingresso da rete, ha la possibilità di installazione in impianti di tipo TRIFASE o PARALLELO attraverso l'utilizzo del codice Leonardo Off-Grid SL, versione SLAVE.
  • Page 17: Caratteristiche Meccaniche E Peso

    Leonardo Off-Grid GE Py / SL Manuale utente 8. CARATTERISTICHE MECCANICHE E PESO Leonardo Off-Grid 4kW/3000/48 GE Py = 25 kg Leonardo Off-Grid 4kW/3000/48 SL = 22 kg Leonardo Off-Grid 4kW/5000/48 GE Py = 37 kg Leonardo Off-Grid 4kW/5000/48 SL= 34 kg...
  • Page 18: Caratteristiche Elettriche

    Leonardo Off-Grid GE Py / SL Manuale utente 9. CARATTERISTICHE ELETTRICHE Leonardo Off-Grid Leonardo Off-Grid 4kW / 3000 / 48 GE Py 4kW / 5000 / 48 GE Py Potenza di uscita 3.000VA 6.000W 5.000VA 10.000W Pout Tensione di batteria...
  • Page 19: Garanzia Di Legge

    Il prodotto difettoso dovrà essere rispedito alla Western CO. srl o a società delegata dalla Western CO. srl a fare assistenza sul prodotto, a spese del cliente, assieme ad una copia della fattura di vendita, sia per la riparazione che la sostituzione garantita.
  • Page 21: Leonardo Off-Grid Ge Py

    • LITHIUM Batteries: PYLONTECH house until it is fully self-sustaining. The Leonardo Off-Grid GE Py makes it easy and immediate the use of energy • Low battery protection produced by photovoltaic modules, for the supply of domestic consumptions, with the aid of a genset (back-up) in case of reduced •...
  • Page 22 WARNING: do not lift heavy objects without assistance General Western CO. declines all liability if the standards for correct installation are not respected and is not liable for the systems upstream or downstream of the equipment supplied by it. It is strictly forbidden to make any modifications to the equipment. Any modification, manipulation or alteration to the product, not specifically agreed with the manufacturer, concerning software or hardware, shall immediately void the warranty.
  • Page 23 • Check the correct environmental and logistic conditions also during operation • Western CO. reserves the right to operate remotely (if the inverter is connected to the internet), to make changes or updates that improve the functions of the system without prior notice to the customer Tolerance of readings The data provided by the inverter may differ from readings taken by certified measuring instruments (e.g.
  • Page 24 Leonardo Off-Grid GE Py User manual Unpacking and inspections Please remember that the packaging (cardboard, cellophane, staples, adhesive tape, straps, etc.) can cut and/or injure if not handled with care. They should be removed with appropriate means and not left in the hands of irresponsible persons (e.g.
  • Page 25 Leonardo Off-Grid GE Py User manual Contents LEONARDO OFF-GRID GE Py ........................... 1 1. LEONARDO OFF-GRID GE PY WORKING PRINCIPLES ..................6 1.1. Operating Logic ............................7 1.2. Internal Diagram ............................7 2. INSTALLATION ..............................8 2.1. Mechanical Installation ..........................8 2.2.
  • Page 26: Leonardo Off-Grid Ge Py Working Principles

    User manual 1. LEONARDO OFF-GRID GE PY WORKING PRINCIPLES Leonardo Off-Grid GE Py is designed to achieve direct energy savings through the use of photovoltaic energy and other renewable sources; the photovoltaic system is managed by the charge controller with 4 independent MPPT inputs;...
  • Page 27: Operating Logic

    AC-IN input connection from the genset, if available for housing, with a nominal equal to at least the power of the Leonardo Off-Grid GE Py inverter. The Leonardo Off-Grid has the AC-OUT output dedicated to the connection of domestic consumptions, also powered in case of failure or absence of the genset.
  • Page 28: Installation

    2.1. Mechanical Installation a) Install Leonardo Off-Grid GE Py in a dry and adequately ventilated place, fixed on a non-combustible surface and positioned in order to have a space free of obstacles of at least 20 cm around the device so to have the cooling by forced air convection.
  • Page 29: Wiring

    2.2.1.1. AC Side Protections Leonardo Off-Grid GE Py it is equipped with an AC-OUT alternating current output line and an AC-IN alternating current input line. Since the appliance is equipped with a NEUTRAL - TT system grounding conductor, the AC-OUT alternating...
  • Page 30: Dc Connections

    Leonardo Off-Grid GE Py User manual 2.2.2. DC Connections 2.2.2.1. Pylontech Batteries Connect the quick terminals of the supplied power cables: positive (+, orange), negative (-, black) to the battery and the CAN communication cable (included in the supply), as in Pic.6.
  • Page 31: Inverter Circuit Breaker

    Leonardo Off-Grid GE Py User manual 2.2.2.2. Photovoltaic Modules When choosing the configuration of the string of modules to be used in the system, it is necessary to strictly follow the indications in the following table. Features of PV modules Power for each input 1000W 8max 1150 Wp).
  • Page 32: Energy Manager External Signals

    N.B .: to properly shut down the system to follow the above procedure in reverse. 5. ENERGY MANAGER EXTERNAL SIGNALS On the lateral side of Leonardo Off-Grid GE Py there are the working reports of the inverter. If on, it indicates the...
  • Page 33 Leonardo Off-Grid GE Py User manual Charge status Table SOC charge status level 5, the actually stored energy in the battery is in an interval of between 80% - 100% of its nominal capacity. SOC charge status level 4, the actually stored energy in the battery is in an interval of between 60% - 80% of its nominal capacity.
  • Page 34: System Testing

    7. THREE-PHASE OR PARALLEL APPLICATIONS WITH SLAVE SL VERSION Leonardo Off-Grid GE Py, Master version for applications with network input, can be installed in a THREE-PHASE or PARALLEL-type installation through the use of the code Leonardo Off-Grid SL, SLAVE version.
  • Page 35: Mechanical Features And Weight

    Leonardo Off-Grid GE Py User manual 8. MECHANICAL FEATURES AND WEIGHT Leonardo Off-Grid 4kW/3000/48 GE Py = 25 kg Leonardo Off-Grid 4kW/5000/48 GE Py = 37 kg Leonardo Off-Grid 4kW/3000/48 SL = 22 kg Leonardo Off-Grid 4kW/5000/48 SL= 34 kg...
  • Page 36: Electrical Features

    Leonardo Off-Grid GE Py User manual 9. ELECTRICAL FEATURES Leonardo Off-Grid Leonardo Off-Grid 4kW / 3000 / 48 GE Py 4kW / 5000 / 48 GE Py Output power Pout 3.000VA 6.000W 5.000VA 10.000W Battery Voltage Vbatt 40.0V 40.0V Output voltage...
  • Page 37: Warranty Of Law

    The defective product must be returned to Western CO. srl or to a company delegated by Western CO. srl to provide assistance on the product, at the expense of the customer, together with a copy of the sales invoice, both for repair and guaranteed replacement.
  • Page 39 LEONARDO Off-Grid GE Py Appendice Appendix Appendice Appendix Schema di collegamento base Basic Wiring Diagram Schema di collegamento con regolatori esterni WRM30+ Wiring Diagram with external WRM30+ charge controllers Schema di collegamento parallelo Parallel Wiring Diagram Schema di collegamento trifase...
  • Page 47 Questo documento è di proprietà di WESTERN CO. Srl - Tutti i diritti sono riservati - La riproduzione e l'uso delle informazioni contenute nel presente documento sono vietati senza il consenso scritto di WESTERN CO. Srl. This document is the property of WESTERN CO. Srl - All rights are reserved - Reproduction and use of information contained within this document is forbidden without the written consent of WESTERN CO.

This manual is also suitable for:

Leonardo off-grid slLeonardo off-grid 4kw/3000/48 ge pyLeonardo off-grid 4kw/5000/48 ge pyLeonardo off-grid 4kw/3000/48 slLeonardo off-grid 4kw/5000/48 sl

Table of Contents