GE-NUTRI WIRING DIAGRAM WARNINGS AND PRECAUTIONS Although the manufacturer has made every effort to ensure the accuracy of the information contained herein, this document is subject to change without notice due to ongoing product development. WARNINGS AND PRECAUTIONS Equipment, probe failure, blown fuses and/or tripped breakers may prove harmful to the contents of the building.
GE-NUTRI WIRING DIAGRAM Electrician’s notes (PROBE WIRING) SHIELDED WIRE AWG #22 WITH 16/30 STRANDING, 500ft (150m) MAXIMUM LENGTH (Ex.: DECA 73-310). For other probe, refer to specific probe manual for appropriate maximum length and wire size or use AWG #22, 500ft (150m) MAXIMUM LENGTH.
Failure to do so may void the warranty. Unpacking Unpack the GE-NUTRI Controller and inspect contents for damage. Should the contents appear to be damaged, contact your local distributor to return the equipment.
GE-NUTRI INSTALLATION General installation guidelines GE-NUTRI Controller It is recommended to install the unit in a hallway to limit the GE-NUTRI Controller exposure to noxious gases. In order to avoid condensation problems inside the controller, it is recommended to install the GE-NUTRI Controller on an inside wall. If it is not possible, use spacers to have an air gap between the wall and the GE-NUTRI Controller.
GE-NUTRI INSTALLATION The backup system and alarm must be thoroughly tested and verified as working properly before using the ventilation system. Mounting The enclosure must be mounted in a location that will allow the cover to be completely opened. Fasten the four brackets to the four mounting holes on the back of the enclosure using the four screws provided with the brackets.
GE-NUTRI INSTALLATION Typical power backup wiring A backup relay (DPDT) is connected to the power source 1 in normal operation but will switch to the power source 2 if source 1 is disabled. The backup relay should be selected to ensure it is able to support the required power load.
GE-NUTRI INSTALLATION Typical alarm connection wiring The GE-NUTRI Controller provides a normally open and normally closed dry contact to set off an alarm in case low or high temperature condition occurs. Moreover, this same contact can be used to signal a power failure or other malfunctions.
Put the power on Secure the front panel with a lock GE-NUTRI Controller compatible probes This is the list of all compatible probes that can be connected with the GE-NUTRI controller and a short description of their function. Micro Switch On/off switch read by the controller ...
GE-NUTRI INSTALLATION Specifications Storage temperature -4°F to 131°F (-20°C to 55°C) Operating temperature 32°F to 122°F (0°C to 50°C) Humidity 90% maximum Non-condensing Weight 9 lb (4.1 kg) Size 14 1/2” x 13 1/4” x 5.5” (36 cm x 33 cm x 13.9 cm)
Page 19
GE-NUTRI INSTALLATION OUTPUT RELAYS (2HP) Maximum Load 2HP @ 240VAC, 1HP @ 120VAC, 12A@240VAC Notice These relays are rated by UL and CSA at 2HP @ 240VAC, 1HP @ 120VAC. However, for outputs requiring frequent activation (ex: minimum ventilation fans...
GE-NUTRI INSTALLATION Troubleshooting SYMPTOM CAUSE SOLUTION Screen is blank GE-NUTRI Controller is not Make sure the control is powered. powered. The connector between the Make sure both top and the main boards or connectors are properly between the relay control connected.
-NUTRI USER’S GUIDE USER’S GUIDE USER’S GUIDE Control Control Description Description Description Section C Section C-22 GE-NUTRI NUTRI...
Page 23
GE-NUTRI USER’S GUIDE 1. Alarm LED The Alarm LED will come ON whenever an alarm situation occurs. 2. Stage List with LED On the left-hand side of the faceplate appears a list of multi-purpose outputs vertically aligned, next to that is a LED list. A LED comes ON whenever the respective stage is active.
GE-NUTRI USER’S GUIDE Required Equipment Quantity Description GE-NUTRI Controller Optional Equipment Quantity Description PC Com. Board PC Interface Up to 16 CSD-1A RF-IN 2 8 Input Board (x1399) Versions Configuration Minimum Version Processor Date Modification Version C2V27V0 06/15/2017 - New.
Page 25
GE-NUTRI USER’S GUIDE C2V27V3 04/20/2018 - Reformat main menu. - Reformat settings screens to include cycle parameters. - Reformat manual operation screen. - Change “output” for “relay”. - Add message when a backup feed auger is activated. - Add stop by proximity switch for feed auger activated in manual mode.
Page 26
GE-NUTRI USER’S GUIDE C2V27V7 08/23/2019 - Modification of feed backup logic for feed auger backup logic. - Add feeding alarm for chain feeder, feed auger, chain feeder drop and feed auger drop mode. - Reduce the maximum proximity switch to - Modification on default values.
GE-NUTRI USER’S GUIDE General Characteristics The GE-NUTRI automatic system can distribute several type of feed to animals. The GE-NUTRI can handle up to 4 different programs simultaneously. Each program can distribute feed up to 10 times a day (10 cycles). An alarm is there to detect if a bin is empty or one of the feed auger has a problem.
Page 28
GE-NUTRI USER’S GUIDE The feed auger stops when the proximity switch indicates that the manger is full for the filter’s end time. The feeder continues for an adjustable delay until the end of the cycle. In feed auger mode, the general sequence of a cycle operates as follows: At the start time of a cycle, feed augers assigned to the cycle’s feed type...
GE-NUTRI USER’S GUIDE MAIN MENU M a i n M e n u C l o c k : 1 4 : 3 8 M a n u a l O v e r r i d e A l a r m s...
Page 31
GE-NUTRI USER’S GUIDE 6. These parameters are used to access the PROGRAM STATUS {1-4} screen (page C-32) of the corresponding program. 7. These parameters are used to access the SETTINGS PROGRAM {1-4} screen (page C-37) of the corresponding program. 8. These parameters display the feed type actually being distributed by the corresponding program.
GE-NUTRI USER’S GUIDE MAIN MENU PROGRAM STATUS {1-4} ACTUAL STATUS S t a t e P r o g # : M F I n p u t o u t p u t P . S w i t c h 1 : E m p t y P .
Page 34
GE-NUTRI USER’S GUIDE 6. These parameters display the current position of actuators. If the regulator detects a defective potentiometer, the corresponding parameter will display "*Po". If the cooling function is enabled, the current position will alternate with "*RE". If the regulator cannot read the value of the potentiometer, the corresponding parameter will display "*ER".
GE-NUTRI USER’S GUIDE MAIN MENU PROGRAM STATUS {1-4} ACTUAL STATUS FEED AUGER {1-8}, FEEDER HISTORY H i s t . A u g # C L R < 0 > 1 0 2 0 3 0 4 0 5 0...
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} FEEDS PROGRAM {1-4} FEED {1-4} PROGRAM {1-4} F e e d # P r o g # V i s : V i s 1 ( 0 0 0 0 ) P .
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} TIMERS PROGRAM {1-4} T i m e r s P r o g # A c t u a t o r F e e d i n g P . S w i t c h F i l t e r...
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} TIMERS PROGRAM {1-4} ACTUATORS TIMERS A c t u a t o r T i m e r s S t a r t i n g : 6 0 S e c D i s t r i b .
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} TIMERS PROGRAM {1-4} PROXIMITY SWITCH FILTERS P . S w i t c h F i l t e r s T i m e ( s e c )
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} TIMERS PROGRAM {1-4} FEEDER TIMER F e e d e r T i m e r F e e d e r : 2 0 m i n This screen is only accessible in multi-feed, chain feeder and chain feeder drop.
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} TIMERS PROGRAM {1-4} ON/OFF FEEDING PERIODS O n / O f f P e r i o d s T i m e ( S e c ) O F F...
GE-NUTRI USER’S GUIDE MAIN MENU SETTINGS PROGRAM {1-4} TIMERS PROGRAM {1-4} PURGE TIMER P u r g e T i m e r T i m e : 2 0 m i n This screen is only available in multi-feed mode.
GE-NUTRI USER’S GUIDE MAIN MENU ALARMS ALARM HISTORY A l a r m H i s t . C L R 1 1 N o v - > 2 2 : 0 8 A l r m M i n A u g : 8 8 8 8 1 1 N o v - >...
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION I n s t a l l a t i o n V e r s i o n : C 2 V 2 7 V 9 P r o c e s s o r : 1 0...
Page 57
GE-NUTRI USER’S GUIDE 7. This parameter is used to select the identification number that will be used when communicating with the remote access software. Each controller must have a unique identification number. When RF CHANNEL [7] is set to any value other than "OFF", this parameter will disappear.
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION FEEDER {1-4} INSTALLATION F e e d e r P r o g # I n p u t : - - R e l a y : - - X 1. This parameter is used to select the feeder input for a program. This input inform if the feeder is active or not.
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION INSTALLATION PROGRAM {1-4} INSTALLATION FEED AUGER PROGRAM {1-4} F e e d A u g e r P r o g # N u m b e r s A u g 1 ( 0 0 0 0 ) A u g 5 ( 0 0 0 0 )
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION INSTALLATION PROGRAM {1-4} PROXIMITY SWITCH INSTALLATION PROGRAM {1-4} P r o x . S w i t c h P r o g # I n p u t s M o d e P .
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION INSTALLATION PROGRAM {1-4} TRANSMISSION CHAIN INSTALLATION PROGRAM {1-4} T r a n s . C h a i n P r o g # I n p u t s M o d e C h a i n 1.
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION INSTALLATION PROGRAM {1-4} ACTUATORS INSTALLATION PROGRAM {1-4} A c t u a t o r s P r o g # A c t u a t o r P o t : - - R e l a y s : 1 - 2 C a l i b .
GE-NUTRI USER’S GUIDE MAIN MENU INSTALLATION ACTUATORS INSTALLATION PROGRAM {1-4} ACTUATOR {1-4} CALIBRATION & CONFIG A c t # C a l i b . & C o n f i g P r e c i s i o n : 1 % T o t a l R u n T i m e : 1 m 0 0 s A c t u .
Page 65
GE-NUTRI USER’S GUIDE 5. This parameter is used to set the potentiometer lower limit for the actuator calibration. This will effectively define the lowest possible value for the actuator’s potentiometer. To obtain this value, completely close the actuator using OPER MANUAL [4]. Once the actuator is completely closed, press when the cursor is on this parameter.
GE-NUTRI USER’S GUIDE MCHIP DETECTED - U p l o a d / D o w n l o a d * * M C H I P D e t e c t e d * * * D N L D C o n f i g . S u r e ? Y U P L D C o n f i g .
Page 68
GE-NUTRI USER’S GUIDE This parameter is used to confirm an upload of the configuration from the controller to the MCHIP. When the button is pressed while the SELECT cursor is on this parameter and the latter is adjusted to "Y", the upload will begin.
GE-NUTRI USER’S GUIDE Alarm Message Table Situational Alarm Message List These alarms will activate the alarm relay and the alarm LED will light up when the condition is present. When the situation is corrected, the alarm relay will deactivate and the alarm LED will light up.
Page 70
GE-NUTRI USER’S GUIDE “A u g M a x - A feed auger has continuously stayed active for a period of MAX A l r m : TIME[3]. # # # # ” - An actuator assigned to program # in FAD or CFD mode has a position “D r o p P r o g...
Page 71
GE-NUTRI INDEX / WARRANTY INDEX / WARRANTY GE-NUTRI SECTION D GE-NUTRI Section D-71...
Typical alarm connection wiring ............... 16 Powering up procedure ..................17 Verify all connections ..................17 Hermetically close the GE-NUTRI Controller ............17 Put the power on ....................17 Secure the front panel with a lock ............... 17 GE-NUTRI Controller compatible probes ............17 GE-NUTRI Controller compatible modules ............
GE-NUTRI INDEX / WARRANTY TABLE OF CONTENTS Section C Control Description ....................22 Required Equipment ................... 24 Optional Equipment .................... 24 Versions Configuration ..................24 General Characteristics ..................27 Pre-Initialization ....................29 Main Menu ......................30 Program Status {1-4} ..................32 Actual Status .......................
Page 74
GE-NUTRI INDEX / WARRENTY Limited Warranty ....................74 Limited Warranty The manufactured equipment and supplied components have gone through rigorous inspection to assure optimal quality of product and reliability. Individual controls are factory tested under load however, the possibility of equipment failure and/or malfunction may still exist.