Cleaning & Maintenance
• Ensure the water is changed every 24 hours – If the unit is not being
used drain all the water from it using the plug on the base
• Clean the interior & exterior with warm soapy water
• Dry with a clean soft cloth
• DO NOT submerge the ice maker in water or use water sprays to clean
it
• Always clean your Arctica Ice Maker daily
• Periodically it is advised to run a full tank of water through the ice maker
with lemon juice to remove any smell that might build up
Troubleshooting
Fault
Add Water indicator is on
Ice Full indicator is on
No ice being formed
Transportation and Storage
Please handle your ice maker with care to prevent any damage to the unit and
internal parts. The ice maker should be stored somewhere which is ventilation
and non-corrosive gas.
Do not store any flammable objects near the equipment.
Technical Information
HEA653 – Arctica Ice Maker
Voltage ~230v 50/60Hz
Refrigerant : R134a/62g
Weight : 9.2 kg
Dimensions : 242 x 358 x 328mm
Possible Cause
Lack of water
Ice basket is full
Room or water temp is
too high
Pipe is blocked
Solution
Stop the ice maker, fill with
water, press ON/OFF to
restart the unit
Empty the ice basket and
restart the unit
Room temp should be
10-43c, water temp should
be 8-32c
Contact your Arctica
distributor