Probe Tip
* Uses 1.55V, alkaline type LR41, L736, SR41 silver oxide type or equivalent
Follow Instructions for Use. This document provides important product operation and safety information regarding
this thermometer. Please read this document thoroughly before using the device and keep for future reference.
Thank you for purchasing the Vicks Digital Thermometer, a professionally accurate instrument for faster and easier temperature taking. Please read these
instructions carefully to ensure accurate temperatures and safe operation. When used properly, this high quality product will give you years of accurate,
dependable service.
IMPORTANT SAFETY INFORMATION
• High, prolonged fever requires medical attention especially for young children. Please contact your physician.
• Do not allow children to take their temperatures unattended.
• Do not allow children to walk or run during temperature taking.
• The thermometer is only suitable for the measurement of body temperature. The use of this thermometer is not intended as a substitute for
consultation with your doctor.
• The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, the accuracy of
measurements will not be affected.
• Do not use the device if you think it is damaged or if anything appears unusual.
• Do not store the unit under direct sunlight, at a high temperature, or in high humidity or dust. Performance may be degraded.
• Using the unit in the immediate vicinity of mobile phones, microwave appliances or other devices with strong electromagnetic fields may result in
impaired functioning.
• Do not use this device close to strong electromagnetic fields, such as mobile telephones or radio installations. Keep a distance from such devices
when using this unit.
CHANGING TEMPERATURE SCALE FROM °C TO °F OR °F TO °C
The default temperature scale is Celsius (°C). With the thermometer in the OFF position, hold down the On/Off button until the display shows "L". Release
the button. To choose desired scale, press the button again to move between the "F" or "C" icon shown above the "M". Once the "C" or "F" starts to blink,
push the button again to turn off the thermometer. You can now turn on the thermometer and the display will be in Fahrenheit (°F) or Celsius (°C) based
on the scale you set in the above steps. Your thermometer will return to Celsius(°C) readings when you replace your battery. You can repeat this process
to switch to Fahrenheit (°F).
TEMPERATURE READINGS
Temperature readings vary from person to person. Although there is no one "normal" temperature reading, a temperature, taken orally, ranging between
36.1 °C / 97 °F to 37.7 °C / 100 °F is considered normal. A rectal temperature is generally 0.5 °C / 1 °F higher and an underarm (axillary) temperature
will be 0.5 °C / 1 °F lower.
The best method to determine your own normal temperature is to use the thermometer when you are feeling well. Record your reading twice a day
(early morning and late afternoon). Take the average of the two temperatures. This is considered your normal body temperature. Any variation from it may
indicate some sort of illness and you should consult your physician.
BEFORE USE
Your Vicks Digital Thermometer is a 3-in-1 thermometer for oral, rectal, or underarm use. Whichever method
is used, it is recommended that for 15 minutes prior to use, avoid eating or drinking any liquids, exercising, taking
showers or baths or smoking.
PROBE COVERS
Disposable probe covers are provided with your Vicks Digital Thermometer. Place a cover on the probe tip
each time the thermometer is used to help prevent spread of germs.
OPERATING YOUR VICKS DIGITAL THERMOMETER
1. TURNING THE UNIT ON
1. Turn unit on by pressing the On/Off button (Fig. 1).
2. Wait for unit to get ready.
– A beep will sound and the display will perform a self-test for about 2 seconds (Fig. 2).
– The display will show last measurement for 2 seconds (Fig. 3).
– After about 2 seconds, the display will show it's ready (Fig. 4).
2. SELECTING A TEMPERATURE LOCATION
Oral Use
1. It is suggested to use a probe cover for Oral Use. Discard the probe cover after taking a temperature.
2. It is important to place the tip of the thermometer well under the tongue to get a good, accurate reading. (Fig. 5)
Place sensor tip in areas marked with "
3. When the peak temperature is reached, unit will beep for approximately 10 seconds and the "°C/°F" sign will stop
flashing.
4. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will
automatically turn off after approximately 10 minutes.
5. Dispose of used probe cover and wash the thermometer as recommended.
Under-the-arm (Axillary) Use
This method is used for babies and young children.
1. Wipe the underarm with a towel.
2. Place the probe tip under the arm so the tip is touching the skin and position your arm next to your body
(Fig. 6). With a young child, it is sometimes helpful to hug the child to keep their arm next to their body.
This ensures that the room air does not affect the reading.
3. When the peak temperature is reached, unit will beep for approximately 10 seconds and the "°C/°F" sign will stop
flashing. The temperature is now confirmed.
Note: This method produces a temperature 0.5 °C / 1 °F lower than a temperature taken orally.
4. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will
automatically turn off after approximately 10 minutes.
5. Wash the thermometer as recommended.
Rectal Use
Commonly used for babies, young children, or when it is difficult to take an oral or underarm temperature.
1. Cover the thermometer's tip with a probe cover and lubricate with a water-soluble jelly for easier
insertion. Do not use a petroleum jelly. Read the label of the lubricant to be sure you are using the
right kind.
2. Lay the patient on his/her side. If the patient is an infant, the proper position for a baby is to lay on its
stomach with legs hanging down, either across your knees or at the edge of a bed or changing table.
This positions the infant's rectum for safe and easy insertion of the thermometer.
3. Gently insert the tip of the thermometer NO MORE THAN 1.27 cm or 1/2 inch into the rectum. If you
detect resistance, stop. Hold the thermometer in place during measurement.
4. When the peak temperature is reached, unit will beep for approximately 10 seconds and the "°C/°F" sign will stop flashing. The temperature is
now confirmed.
Note: This method produces a temperature 0.5 °C / 0.9 °F higher than a temperature taken orally.
5. Turn the thermometer off by pressing the On/Off button. If you forget to turn it off, the thermometer will automatically turn off after approximately 10 minutes.
6. Dispose of used probe cover and wash the thermometer as recommended.
FEVER SIGNAL
The Fever Signal feature alerts you of temperature readings above 37.5 °C / 99.5 °F with a flashing display and a rapid alarm tone that lasts for about 10 seconds.
TO RECALL THE LAST TEMPERATURE
When the thermometer is turned on, the display will show a test, after which the last measured temperature will be shown for approximately 2 seconds
on the LCD display.
CLEANING INSTRUCTIONS
Clean the probe tip by washing with soap and warm water or by disinfecting with rubbing alcohol (70% isopropyl alcohol).
Wipe dry with soft cloth.
DO NOT BOIL OR CLEAN IN DISHWASHER. This will cause the thermometer to no longer function and will void the warranty.
Do not wash the unit with any thinner or chemical solvent.
CHANGING THE BATTERIES
The Vicks Digital Thermometer features a long life battery. When the "
needs replacing.
1. Unscrew the battery cap with a coin.
2. Replace the battery with a 1.55V, LR41 alkaline, L736 or SR41 silver oxide type or equivalent. Insert the new battery with the positive (+) side facing
the back of the unit.
3. Replace the cover and screw back into place, making sure that the cap is secure to protect the battery compartment from moisture.
WARNING - KEEP BATTERIES OUT OF REACH OF CHILDREN. If you suspect a button battery has been ingested, call Poisons Information immediately on
13 11 26. Ensure battery compartment is correctly secured.
Batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations, not with domestic waste.
SPECIFICATIONS
Type:
"BPA Free" Implies:
Battery Lifetime:
Accuracy in water bath:
Temperature Range:
Operating Temperature:
Storage Temperature:
Beeper:
Error Messages:
Expected Service Life:
The stipulations of EU-Directive 93/42/EEC for
Medical Devices Class IIa have been fulfilled.
0044
Device standard: • EN 12470-3
• IP22: Protected against solid foreign objects of 12.5 mm diameter and greater. Protected against vertically falling water drops when the device is tilted up to 15°.
TEST PROTOCOL (Laboratory use only)
Test Protocol for testing to ASTM Standard E1112:
1. Place thermometer into a stable liquid bath with a temperature set above 35°C (95°F). The tip of the thermometer should be approximately 0.8 inches
(2cm) below the surface.
2. Wait for 10 seconds, then turn thermometer on by pressing the blue "On/Off" button.
3. When the measurement is completed (approximately 15 seconds), record the temperature reading.
4. Do not touch or hold thermometer when taking a measurement in liquid bath.
LIFETIME WARRANTY
This product has been produced with the greatest care for normal, household use. Following directions carefully will ensure dependable operation. If for
any reason (other than misuse or normal battery operation) you are dissatisfied with your Vicks Digital Thermometer, we will repair or replace it, at our
option, at no charge during the lifetime warranty period. Modification to the product by the consumer is not authorised and voids the warranty.
If the thermometer does not function properly, first check the battery. Replace if necessary. Batteries and packaging are excluded from the warranty.
If you experience unsatisfactory operation, please contact Felton Grimwade & Bosisto's. If repair is required under the warranty period, the product
should be returned with proof of purchase to Felton Grimwade & Bosisto's service centre.
The purchaser assumes responsibility for the proper care and use of the product in accordance with the printed operating manual. The purchaser or
user must make his or her judgment as to when to use the product and the length of use. Keep the operation manual available as it is your guide to safe,
efficient operation.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a major failure.
This product is manufactured by ONBO Electronic (Shenzhen) Co., Ltd. for
Kaz USA, Inc., a Helen of Troy Company. Certain trademarks used under
license from The Procter & Gamble Company or its affiliates.
© 2020 All rights reserved.
Made and printed in China
ONBO Electronic (Shenzhen) Co., Ltd.
No. 138, Huasheng Road, Langkou Community, Dalang Street, Longhua
District, Shenzhen, China
3
". Keep mouth closed and sit still to help ensure an accurate measurement.
Digital Thermometer (Predictive)
1. Plastics used to make the thermometer are BPA Free
2. A comprehensive audit to ensure a BPA Free process
3. A screening test based
More than 200 hours of continuous operation
±0.1 °C between 34.0 °C - 42.0 °C at room temperature of 21.6 °C
±0.2 °F between 93.2 °F - 107.6 °F at room temperature of 71 °F
32.0 °C-42.9 °C (90.0 °F - 109.9 °F). If less than 32.0 °C (90.0 °F) an "L" is displayed.
If more than 42.9 °C (109.9 °F) an "H" is displayed.
+10 °C to +40 °C (50 °F - 104 °F), 15% to 95% RH
-25 °C to 55 °C (-13 °F - 131 °F), 15% to 95% RH
If the device is not used within specified temperature and humidity ranges the technical accuracy of the measurement
cannot be guaranteed.
Unit will beep for approximately 10 seconds when peak temperature is reached.
Valid complete = 10 times short beeps
Fever = When ≥ 37.5 °C (99.5 °F), 35 times short beeps
The display will read "Err" when a malfunction occurs and the thermometer will power off.
5 years
• IEC 60601-1-11
www.kaz.com/vicks
Large Display Window
" appears in the lower right of the display, the battery is exhausted and
BF Type applied part
• ASTM E1112
• IEC 60601-1
Distributed by:
Felton Grimwade & Bosisto's Pty. Ltd.
61-81 Clarinda Road (PO Box 74), Oakleigh South, Victoria 3167, Australia
Customer service:
Free call: 1800 655 841
Website: www.fgb.com.au
Australian sponsor:
RQSolutions Pty Ltd
Suite 1A Level 2, 802 Pacific Highway, Gordon NSW 2072
Displays in °C/°F
IMPORTANT: Before first use,
remove label from the display.
Fig. 2
Fig. 1
Fig. 3
Fig. 4
Fig. 5
Fig.6
• IEC 60601-1-2 (EMC)
E-mail: mail@fgb.com.au
Battery
Compartment
(on back side)
On/Off Button
P/N: A003634R0
DATE: 05JUN19

Advertisement

loading

Summary of Contents for Vicks V901

  • Page 1 This product has been produced with the greatest care for normal, household use. Following directions carefully will ensure dependable operation. If for any reason (other than misuse or normal battery operation) you are dissatisfied with your Vicks Digital Thermometer, we will repair or replace it, at our option, at no charge during the lifetime warranty period.
  • Page 2 CREATIVE DEPARTMENT ARTWORK SPECIFICATIONS Brand: Vicks Category: Thermometer V901C-AUS Model: Artwork Part #: A003634R0 Die Line Part #: Subject: Owners Manual Region: AU Flat Size: IN: W4.75 x H14.5 MM: W120.65 x H368.3 Scale: 1/1 Material: 80g wood paper Page count: NA...

This manual is also suitable for:

V901c-aus