IMPORTANT FOR THE OPERATOR
This statement is proof of the correct installation and testing of the appli-
ance
This document should be filled out in the presence of the client on concluding
the installation of the appliance and should be conserved as a warranty.
Date.................................................
Appliance type __________________________ Code number _________________
Applicable security
Photoelectric cells
Pneumatic safety tubes _____________
Luminous warning lights ____________
_____________
Radio controls _____________________
STRUCTURAL CONDITION AFTER INSTALLATION
Dimensions: __________________________
Conforms to UNI 8612
YES
Installed by: ___________________________
Address: ______________________________
Interventions carried out after installation
____________________________________________________________________
_____________________________________________________________________
Conserve this document even after the warranty period has expired in order to
facilitate the ordering and replacement of spare parts.
32
N.
Note
___________________________
___________________________
___________________________
Model ____________________
Weight: ___________________
NO Client N.: _________________
Firm: _____________________
Telephone: ________________
CARDIN ELETTRONICA spa
Via Raffaello, 36- 31020 San Vendemiano (TV) Italy
Tel:
+39/0438.404011-401818
Fax:
+39/0438.401831
email (Italy):
Sales.office.it@cardin.it
email (Europe):
Sales.office@cardin.it
Http:
www.cardin.it
CODE Nr.
L183.00
This product has been tried and tested in the manufacturer's la-
boratory, during the installation of the product follow the supplied
indications carefully.
WIRELESS ACCESS CONTROL
SYSTEM
ACD-148
SERIES
MODEL
ACD
148
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACD-148 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cardin Elettronica ACD-148

  • Page 1 Interventions carried out after installation ____________________________________________________________________ _____________________________________________________________________ Conserve this document even after the warranty period has expired in order to facilitate the ordering and replacement of spare parts. CARDIN ELETTRONICA spa Via Raffaello, 36- 31020 San Vendemiano (TV) Italy Tel: +39/0438.404011-401818 Fax: +39/0438.401831...
  • Page 2 Appendix A REMARKS Communications parameters Before commencing with the installation of this appliance make sure Using a P.C. fitted with a serial port controller the following parameters are that you have read the following instructions carefully. required In particular familiarise yourself with the safety devices required by the system, only then will you be able to use them to great effect.
  • Page 3: Table Of Contents

    Enabling/disabling user transmitter channels ......pag. 14 The list appears in the following format Deleting memory ................. pag. 15 ***CARDIN ELETTRONICA S.p.A.*** LIST of accepted former events Printing options................pag. 16 1. 02/04-Transmitter #0001 Channel “A” Activated at 14:06:07.
  • Page 4: Introduction

    ARE YOU SURE? [Y/N] >> The central unit of the ACD-148 is based on a CPU which is able to control up 2000 codes referring to 4 different entrances and exits which can also be subdivided Choosing N the following message will appear into 4 different zones.
  • Page 5: Electrical Specifications

    - displaying a complete list of the systems user’s both enabled and disabled and the display of information regarding the last transition. C A R D I N ACD-148 V. 3102 (1994) Cardin Elettronica S.p.A. At the back of the appliance there are 4 dip-switches allowing zone partitioning (see fig.6 page 18) e.g.
  • Page 6: Interconnection And Wiring

    Complete the choice List of users Choosing option 8 from menu level B a list of all enabled users appears on the screen as follows: CARDIN ELETTRONICA S.p.A. *** ENABLED USER LIST CODE N° CHA CHB CHC CHD ENABLED/DISABLED USER NAME 0 0 0 0 MR.JONES...
  • Page 7 The following message appears on the screen: Backpanel connections Fig.2 ENTER USER NUMBER >>> Introduce the number which appears in the first column of the list D. The following message appears on the screen: ARE YOU SURE? [Y/N] >> Serial line If the answer Y is given the following message appears: Reset CODE #### !!! D E L E T E D !!!
  • Page 8 By choosing option 2 from menu level B you can add the name of the user. This option exists due to the fact that data entered directly into the ACD-148 can- not contain names as it has no alphanumeric keyboard.
  • Page 9: Installation

    If the led fails to light up but the code combinations on the ACD-148 and the ac- If the code is accepted the system asks: cess keys are the same contact your dealer.
  • Page 10: Initialising The System

    C A R D I N ***** ACD-148 ***** **** USERS MANAGEMENT **** In its normal operating mode the ACD-148 does not require enabling via the 1. ADD USERS 6. DISABLE USER CODE serial key; this key is only required when system management tasks are to be 2.
  • Page 11: Memorising A User Code

    RESET (activated by pressing the relative button on the back of the ACD-148) or until the next SERIAL TIMEOUT pressing CHA key: code ------------> Section A of the TX interruption.
  • Page 12 Choose Nr. 1 from the main menu to enter the system menu. The following menu appears on the screen: 7. Press the MEMO key of the ACD-148 and the key relative to channel A of the transmitter S48 at the same time.
  • Page 13: Cancelling A User Code

    1=DEL 2=DIS 3=EN 4=CH 0=OUT >> 0 SERIAL TIMEOUT while the following message will appear on the ACD-148 display: 8. Repeatedly press the SET button until a “1” appears in the option indicated by the cursor prompt; CA R D I N...
  • Page 14: Enabling/Disabling A User Code

    9. Press the MODE button. The system answers with: ON-LINE FUNCTION Once the ACD-148 has been installed the four I/O ports can only be accessed ARE YOU SURE ? Y by users who possess a radio control with a correctly memorised code. When a recognised code is received the system performs the following operations: 10.
  • Page 15: Deleting Memory

    INITIAL DELETION OF ALL THE CODES IN MEMORY The ACD-148 stores all the user codes in a non-volatile EEPROM memory which maintains them even during blackouts. In order to initialize the system a procedure is required for deleting all the codes stored in memory.
  • Page 16: Printing Options

    It is possible to ask the system for information regarding all the enabled users. This 1. 02/04-Transmitter #0001 Channel “A” Activated at 14:06:07. information can be printed by connecting the ACD-148 to a printer via the serial 2. 02/04-Transmitter #0002 Channel “B” Activated at 14:12:21.