The JA-112M BUS module for magnetic contact – 2 inputs
and deactivation) of the loop. If enabled the input will only react
to activation and after 2 s it will go to standby automatically.
Inverted input reaction: (valid for an Enabled or Balanced input only)
the default setting for the input reaction is NC (normally closed).
Enabling this option sets the reaction to NO (normally open).
Balancing resistor: can be used for a Single balanced input and for
a Double balanced input. The default value is 1k0*.
For a Single balanced input select the R
from the pre-set values.
For a Double balanced input select the R
for the detection of tampering and activation from the pre-set values
(the selected value applies to both resistors)
Delayed input reaction: time filter to increase the immunity to false
activation 0.5 s* (setting 0.1 s ... 300 s). It determines for how long
the input has to be triggered for the control panel to record (react to)
the activation. For a Double balanced input the setting can be 0.5 s ...
300 s).
Copy of input settings: this button allows you to copy the settings
of the other input to a currently programmed input.
Test input measuring: this tab shows the currently measured
resistance at a specific input (loop). The graphical representation fully
respects the input settings (function, balancing and its value).
It visualizes the current status of the measured value. Due
to the recording of measured values over time it shows a visible curve
with all changes and you can test all detectors this way.
The JA-112M BUS module for magnetic contact – 2 inputs
value of balancing resistor
ACT
and R
value of resistor
TMP
ACT
Technical specification
Power
From control panel BUS 12 V (9 ... 15 V)
Current consumption in standby mode
Current consumption for cable choice (maximum)
Maximum length of cable to the magnetic contact
Dimensions
Weight
Classification
Grade 2/II. indoor general (According to EN 50131-1)
Operational environment
Operational temperature range
Average operational humidity
Certification body
Also complies with
EN 50130-4 ed. 2+A1, EN 55032, EN 50581
JABLOTRON ALARMS a.s. hereby declares that the JA-112M
is
in
compliance
harmonisation
legislation:
2014/30/EU, 2011/65/EU, when used as intended. The original
of
the
conformity
at
www.jablotron.com
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer
or directly to the producer after use.
- 1 -
110 x 44 x 26 mm
Indoor general
-10 °C to +40 °C
75 % RH, non-condensing
Trezor Test s.r.o. (no. 3025)
EN 50131-1 ed. 2+A1+A2, EN 50131-3,
with
the
relevant
European
Directives
No:
2014/35/EU,
assessment
can
be
– the Downloads section.
MLM57101
7 mA
12 mA
100 m
51 g
Union
found