Central States Centra Series Assembly Instructions Manual

20 w x 24 l x 12 h
Hide thumbs Also See for Centra Series:

Advertisement

Quick Links

20
x 24
x 12
W
L
H
ASSEMBLY INSTRUCTIONS
W W W. C E N T R A S E R I E S . CO M
D C E
GUID_INSTL_CENTRASERIES20X24X12_210101

Advertisement

Table of Contents
loading

Summary of Contents for Central States Centra Series

  • Page 1 x 24 x 12 ASSEMBLY INSTRUCTIONS W W W. C E N T R A S E R I E S . CO M D C E GUID_INSTL_CENTRASERIES20X24X12_210101...
  • Page 3: Table Of Contents

    The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. Projects should conform to local building codes. Central States Manufacturing is not responsible for the performance of the material if it is not installed correctly.
  • Page 4: Important Information / Safety

    This manual contains suggestions and guidelines on each project’s conditions. It is the buyer’s responsibility how to erect your Centra Series building. The drawings to verify all applicable code requirements, check all in this guide are for illustration purposes only and...
  • Page 5: Care And Handling

    CARE AND HANDLING STAGE HANDLING Galvalume® steel sheets have a good service life when When unloading panels, extreme caution must be exposed to normal weather conditions however, to employed. Care needs to be used when unloading protect the appearance of panels and trims from panels with a forklift.
  • Page 6 ACCESSORIES PARTS LIST ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY NOTE ACC50 RLCLINGLUE Inside Closure ACC51 Butyl Tape ACC52 MRS10CLEAR Clear Sealant Tube ACC53 GRAYFLEX115 Expandable Foam Roll DOOR47 3070DOOR Commercial Walk Door Steel door leaf only DOOR48 8X3070JAMB Jamb Kit For Walk Door Include jambs, header, threshold, door lever with key lock, hinges,...
  • Page 7 FASTENERS PARTS LIST ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY NOTE FAST3 114(color)MM Metal Screws in Roof color FAST12 114(color)MM Metal Screws in Wall color FAST4 78(color)LAP Lap Screws in Roof color May have additional FAST13 78(color)LAP Lap Screws in Wall color bags of 78LAP in multiple trim colors.
  • Page 8 PANELS PARTS LIST ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY LENGTH PANEL1 RL6(color) Roof Panels 9' 11.5" PANEL23 RL6(color) Wall Panels 14' 5.5" PANEL24 RL6(color) Wall Panels 14' 2.5" PANEL25 RL6(color) Wall Panels 13' 11.5" PANEL26 RL6(color) Wall Panels 13' 5.5"...
  • Page 9 PLATES PARTS LIST ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY LENGTH PLATE35 GIRTCLIP Girtclip PLATE41 RFPEAK Rigid Frame Peak Plate PLATE42 RFHAUNCH Rigid Frame Haunch Plate PLATE43 RFBASE Rigid Frame Base Plate PLATE44 EWPEAK Peak Plate for Endwall Frame PLATE45 RFSPACER Spacer Plate...
  • Page 10 TRIM PARTS LIST ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY LENGTH TRIM2 RLFRC36 Ridge Cap Panels for Roof 8 TRIM14 Eave Trim 14' 2" TRIM15 Ratguard Trim 12' 2" TRIM16 Ratguard Trim 14' 2" TRIM17 Rake Trim 12' 2" TRIM18 REND Rake Trim End Cap...
  • Page 11 TRIM PARTS LIST ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY LENGTH TRIM19 PBOXF PBOXFGRAPHIC TRIM31 Outside Corner Trim 12' 2" TRIM22 Head Trim 10' 3" TRIM26 Head Trim 3' 6" TRIM23 Jamb Trim 10' 2" TRIM27 Jamb Trim 7' 2" TRIM24 Jamb Header Trim 10' 2"...
  • Page 12 PURLINS PARTS LIST ASSEMBLY PART # MANUFACTURER PART # PART MARK QUANTITY LENGTH PURLIN52 C82514R RF1-1 (SIDE COLUMN) 10' 6.8125" C83512R (145mph Wind Option) PURLIN26 C82514R RF1-2,ER-1&2 (RAFTER) 10' 1.1875" C83514R (145mph Wind Option) PURLIN53 C83516R EC-1 (END COLUMN) 11' 5.6875" C83514R (145mph Wind Option) PURLIN54...
  • Page 13 PURLINS PARTS LIST ASSEMBLY PART # MANUFACTURER PART # PART MARK QUANTITY LENGTH PURLIN33 Z82516R G-3 (SIDE GIRT) 11' 7.25" PURLIN34 C82516R DH-1 (END HEADER) 9' 11.5" PURLIN36 B4216R L4X2 (SIDE BASE) 11' 7.25" PURLIN37 B4216R L4X2 (END BASE) 9' 11.5" PURLIN38 B4216R L4X2 (END BASE)
  • Page 14 THIS SECTION IS INTENDED FOR YOUR CONCRETE FOUNDATION SPECIALIST C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 15 THIS SECTION IS INTENDED FOR YOUR CONCRETE FOUNDATION SPECIALIST Dia = 1/2" STEEL LINE 3" PROJ 4" 8" 2" " 8" ANCHOR BOLT PROJECTION Detail A Dia = 1/2" 1. The metal building manufacturer is responsible for the 3" design of the anchor bolt diameter only to permit the transfer of forces between the base plate and the anchor bolt in shear, bearing and tension, but is not responsible for the anchor bolt embedment for transfer of forces to the foundation.
  • Page 16 PROJECT OVERVIEW Completed Frame Structure The above drawing shows the completed frame structure and columns labeled. The columns will be called out periodically throughout the instructions. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 17 PROJECT OVERVIEW Completed Structure The following instructions are to assemble the building as shown above. There will be optional variations to the buildings layout called out on certain pages. Follow those instructions as they pertain to your needs. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 18 STEP 1 Note: To ensure building is square, do not fully tighten REQUIRED PARTS bolts until after STEP29. (4) PURLIN52 (2) PLATE43 (4) PLATE45 (2) PLATE42 PLATE42 (8) PLATE35 FAST54 PURLIN52 PLATE45 PLATE35 PLATE43 DIRECTIONS Assemble Columns A and F Note: Place level on all girt clips throughout installation to ensure level girts.
  • Page 19 STEP 2 REQUIRED PARTS (2) PURLIN53 (10) PLATE35 FAST54 PURLIN53 PLATE35 DIRECTIONS Assemble Columns B and E 1. Layout (1) PURLIN53 corner column for column B. 2. Attach (1) PLATE35 at bottom using FAST54. 3. Attach (2) PLATE35 at 3'6" using FAST54. 4.
  • Page 20 STEP 3 If you are adding a framed opening to the endwall. Refer to page 69 for assembly instructions. REQUIRED PARTS (2) PURLIN54 (12) PLATE35 FAST54 PLATE35 PURLIN54 PLATE35 DIRECTIONS DIRECTIONS Assemble Columns C and D 1. Layout (1) PURLIN54 corner column for column C. 2.
  • Page 21 STEP 4 DIRECTIONS Stand and Anchor Columns A, B, C, D,E and F Note: Anchor bolts and nuts are not included in building package. Anchor bolts are placed by your foundation specialist when laying foundation and corresponding nuts will be provided by your foundation specialist. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 22 STEP 5 REQUIRED PARTS (3)PURLIN32 PURLIN31 (4) PURLIN31 FAST54 PURLIN32 DIRECTIONS Attaching Zee Girts Note: Do not overtighten bolts on wall girts until columns are vertically level. Then tighten bolts. This applies throughout installation. 1. Attach PURLIN31 between columns B & C and D & E using FAST54 as shown. 2.
  • Page 23 STEP 6 REQUIRED PARTS (4) PURLIN33 FAST54 PURLIN33 DIRECTIONS Attaching Zee Girts 1. Attach PURLIN33 between columns B and A and between columns E and F using FAST54 as shown. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 24 STEP 7 REQUIRED PARTS (1) PURLIN53 (5) PLATE35 FAST54 PLATE35 PLATE35 PURLIN53 PURLIN53 DIRECTIONS Assemble Column G 1. Layout (1) PURLIN53 column for column G. 2. Attach (1) PLATE35 at bottom using FAST54. 3. Attach (2) PLATE35 at 3'6" from bottom using FAST54. 4.
  • Page 25 STEP 8 REQUIRED PARTS (1) PURLIN53 (4) PLATE35 FAST54 PLATE35 PURLIN53 DIRECTIONS Assemble Column J 1. Layout (1) PURLIN53 column for column J. 2. Attach (1) PLATE35 at bottom using FAST54. 3. Attach (1) PLATE35 at 3'6" from bottom using FAST54. 4.
  • Page 26 STEP 9 If you are removing standard framed opening. Refer to page 68 for assembly instructions. REQUIRED PARTS (1) PURLIN54 (4) PLATE35 FAST54 Note: Adjust the top PLATE35 FAST46 location to accommodate the door height. FAST54 PLATE35 PURLIN54 FAST46 DIRECTIONS DIRECTIONS Assemble Columns H Note: Adjust the top PLATE35 location to accommodate the door height.
  • Page 27 STEP 10 REQUIRED PARTS (1) PURLIN54 (3) PLATE35 FAST54 FAST46 FAST54 PLATE35 PURLIN54 FAST46 DIRECTIONS Assemble Columns I Note: Adjust the TOP GIRTCLIP location to accommodate the door height. 1. Layout (1) PURLIN54 column for column I. 2. Attach (1) PLATE35 at bottom using FAST46. 3.
  • Page 28 STEP 11 DIRECTIONS Stand and Anchor Columns G, H, I, and J Note: Anchor bolts and nuts are not included in building package. Anchor bolts are placed by your foundation specialist when laying foundation and corresponding nuts will be provided by foundation specialist. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 29 STEP 12 REQUIRED PARTS (3) PURLIN31 FAST54 PURLIN31 DIRECTIONS Attaching Zee Girts 1. At 3'6" and 7'4" from bottom of column, attach PURLIN31 between columns G and H using FAST54 as shown. 2. At 7'4" from bottom of column. Attach PURLIN31 between columns I and J using FAST54 as shown. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 30 STEP 13 REQUIRED PARTS (4) PURLIN33 (1) PURLIN34 FAST54 FAST46 PURLIN33 PURLIN34 DIRECTIONS Attaching Zee Girts 1. Attach PURLIN33 between columns A, J, F, and G as shown. Use FAST54 to fasten to girt clips. 2. Attach PURLIN34 between columns H and I. PURLIN34 can be placed at 7' , 8' , 9' or 10' depending on the height of the door.
  • Page 31 STEP 14 DIY Alternate Method: If lifting machinery is not being used, REQUIRED PARTS assemble center rafters, but do not (4) PURLIN26 attach PLATE41 until STEP 15. PLATE41 (1) PLATE41 (2) PLATE45 FAST54 PLATE45 PURLIN26 DIRECTIONS Assemble Center Rafters 1. Layout (2) PURLIN26 rafters. 2.
  • Page 32 STEP 15 DIY Alternate Method: If lifting machinery is not being used, stand center rafters REQUIRED PARTS and hold in place with 2x4 bracing. Then lift and install PLATE41. FAST54 See instructional video for visualization. DIRECTIONS DIRECTIONS Stand and Install Center Rafter Note: This step will require lifting machinery due to height and weight of components.
  • Page 33 STEP 16 REQUIRED PARTS (2) PURLIN26 PLATE44 (2) PLATE44 FAST54 FAST54 PURLIN26 DIRECTIONS Assemble Endwall Rafters 1. Attach (1) PLATE44 to (1) PURLIN26 using FAST54. 2. Repeat for 2nd endwall rafter. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 34 STEP 17 REQUIRED PARTS FAST54 DIRECTIONS Assemble and Install Endwall Rafters Note: Keep PLATE44 facing interior of building. 1. Attach assembly from previous step to the top of columns J and I using FAST54. 2. Repeat this installation over columns D and E. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 35 STEP 18 REQUIRED PARTS (2) PURLIN26 PURLIN26 FAST54 DIRECTIONS Assemble and Install Endwall Rafters 1. Attach (1) PURLIN26 to the top of columns B and C and attach to installed PLATE44 using FAST54. 2. Repeat this installation over columns H and G. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 36 STEP 19 Note: Base angle is installed to protect the panel edge from concrete corrosion. REQUIRED PARTS (4) PURLIN36 (1) PURLIN37 (3) PURLIN38 (4) PURLIN39 FAST55 PURLIN39 PURLIN38 PURLIN37 PURLIN36 PURLIN39 PURLIN39 PURLIN38 PURLIN36 PURLIN39 DIRECTIONS Install Base Angle Note: When using the FAST55, you will need to predrill 1.25" holes in concrete, and then tap in the FAST55 to secure the base angle.
  • Page 37 STEP 20 REQUIRED PARTS (3) TRIM24 FAST13 TRIM24 JAMB HEADER TRIM NOTE: Leave 1/8" above concrete, this helps prevent future rust. INTERIOR VIEW INTERIOR VIEW DIRECTIONS Trim Framed Opening 1. Install TRIM24 along columns I and H. Cut length to fi t between fl oor and wall girt at top of framed opening. Fasten to column with FAST13 every 24".
  • Page 38 STEP 21 REQUIRED PARTS (1) DOOR47 (1) DOOR48 FAST12 FAST55 DIRECTIONS Option 1: Installing walk door in location shown above Note: Determine where you would like to install your walk door. Illustration above shows walk door between columns J and I, but door can be located in any location. 1.
  • Page 39 STEP 21 CONT. REQUIRED PARTS REQUIRED PARTS (1) DOOR47 (1) DOOR47 (1) DOOR48 (1) DOOR48 (1) FAST12 (1) FAST12 (1) FAST55 (1) FAST55 DIRECTIONS Option 2: Installing door into a alternate location 1. Remove the zee at 3'6" height previously installed in the bay you wish to install your walk door. 2.
  • Page 40 STEP 22 REQUIRED PARTS (1) TRIM26 (2) TRIM27 (2) TRIM23 (1) TRIM22 FAST24 TRIM22 HEAD TRIM TRIM23 JAMB TRIM DIRECTIONS Trim Framed Opening 1. Install TRIM23 along columns I and H, with the mouth of trim facing outward as shown. Fasten to exterior side of the building with FAST24 every 24".
  • Page 41 STEP 23 REQUIRED PARTS TRIM16 TRIM15 TRIM15 RAT GUARD FAST Note: Base of rat guard trim should be below the top of the concrete foundation. TRIM16 RAT GUARD BASE ANGLE RAT GUARD CONCRETE FOUNDATION DIRECTIONS Install Ratguard Trim Note: In this step, you will be installing the trim along the bottom of the building. This trim is available in lengths of 14'2"...
  • Page 42 STEP 24 REQUIRED PARTS (1) PURLIN30 FAST54 PURLIN30 DIRECTIONS Install Eavestruts Bolt PURLIN30 on top of column F and G using FAST54 as shown above. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 43 STEP 25 REQUIRED PARTS PURLIN30 (3) PURLIN30 FAST54 DIRECTIONS Install Eavestruts Repeat previous step between Column B & A, Column A & J, and Column E & F. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 44 STEP 26 REQUIRED PARTS (1) PURLIN29 FAST54 PURLIN29 DIRECTIONS Install Roof Purlins Note: The bolt along the center rafter is temporary.(Do not over tighten) Install PURLIN29 between endwall rafter and center using FAST54 as shown above. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 45 STEP 27 REQUIRED PARTS (1) PURLIN29 FAST54 PURLIN29 DIRECTIONS Install Roof Purlins Note: Remove the bolt from the center rafter before installing PURLIN29. Install PURLIN29 over center rafter as shown above. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 46 STEP 28 REQUIRED PARTS FAST54 DIRECTIONS Install Roof Purlins Use FAST54 to reinforce overlapped PURLIN29 through the web. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 47 STEP 29 REQUIRED PARTS (10) PURLIN29 FAST54 DIRECTIONS Install Roof PURLINS Repeat steps 26-28 to install the remaining roof PURLINS. NOTE: After completing STEP29, ensure that building is square by placing a strap on each corner and ratcheting corner columns until they are level. Then tighten all bolts on building while strapping is still in place. Remove strapping after bolts are properly tightened.
  • Page 48 STEP 30 REQUIRED PARTS (4) PURLIN41 FAST24 PURLIN41 DIRECTIONS DIRECTIONS Install Rake Angle Install PURLIN41 above endwall rafter using FAST24 as shown above. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 49 STEP 31 If you have the wainscot option, please refer to page 64 for assembly instructions. REQUIRED PARTS (1) PANEL7 Note: Install Top & FAST12 Bottom fastener line fi rst before securing middle of panel. PANEL7 CAUTION WALL PANEL To prevent rust, BASE ANGLE leave a 1/8"...
  • Page 50 STEP 32 REQUIRED PARTS (7) PANEL7 FAST12 FAST13 PANEL7 Note: Use FAST12 to attach the panels to the girts. Use FAST13 when the panels overlap. Top & Bottom Middle FAST13 FAST13 DIRECTIONS Install Wall Sheeting Also, some panels may be overlapped more than 1 rib to avoid cutting. If necessary, panel may be cut long ways at ending edge of sidewall.
  • Page 51 STEP 33 REQUIRED PARTS (8) PANEL7 FAST12 FAST13 PANEL7 DIRECTIONS Install Wall Sheeting Also, some panels may be overlapped more than 1 rib to avoid cutting. If necessary, panel may be cut long ways at ending edge of sidewall. 1. Repeat STEP 31 and 32 for the other sidewall. 2.
  • Page 52 STEP 34 REQUIRED PARTS (1) PANEL23 (1) PANEL24 (2) PANEL25 (1) PANEL27 (2) PANEL28 FAST12 FAST13 PANEL23 PANEL24 PANEL25 PANEL25 PANEL27 PANEL28 PANEL28 DIRECTIONS Install Wall Sheeting Also, some panels may be overlapped more than 1 rib to avoid cutting. If necessary, panel may be cut long ways at ending edge of sidewall.
  • Page 53 STEP 35 REQUIRED PARTS (1) PANEL23 (1) PANEL24 (2) PANEL25 (1) PANEL27 (2) PANEL28 FAST12 FAST13 PANEL23 PANEL25 PANEL24 PANEL25 PANEL27 PANEL28 PANEL28 DIRECTIONS Install Remaining Wall Panels Also, some panels may be overlapped more than 1 rib to avoid cutting. If necessary, panel may be cut long ways at ending edge of sidewall.
  • Page 54 STEP 36 REQUIRED PARTS (4) TRIM31 FAST23 TRIM31 COLUMN TYPE TRIM31 AND ORIENTATION MAY VARY OUTSIDE CORNER WALL PANEL PURLIN DIRECTIONS Install TRIM21 Install all 4 TRIM31 with FAST23 along the corners of the wall panels. Place fasteners to match fastener line on wall panels (do not overtighten).
  • Page 55 STEP 37 REQUIRED PARTS (4) TRIM14 FAST12 ACC50 ACC50 TRIM14 INSIDE CLOSURE EAVE TRIM TRIM14 WALL PANEL EAVE STRUT Install TRIM14 1. Place ACC50 on top of TRIM14 before installing. Line up rib profi le of closure with wall panel rib profi le. Place on edge of top leg of trim.
  • Page 56 STEP 38 If you are installing gutters, please go to page 70 before proceeding. REQUIRED PARTS Tip: Squareness is key on this fi rst panel. (4) PANEL1 Start by aligning the panel along the rake FAST3 Note: Do not angle. Then measure that each side is fasten top row.
  • Page 57 STEP 39 PANEL1 REQUIRED PARTS (15) PANEL1 ACC51 FAST4 FAST3 Top & Bottom Middle FAST4 FAST4 DIRECTIONS Finish Sheeting the Roof 1. Use FAST3 to secure panels to the purlins. Use FAST4 when securing the panels together. 2. Do not overlap roof panel more than one rib, if the length of your building is not divisible by 3 then your last panel will need the excess cut off .
  • Page 58 STEP 40 REQUIRED PARTS TRIM2 (8) TRIM2 RIDGE CAP FAST3 ACC51 TRIM2 ROOF PANEL Tip: To locate the center of ridge on ZEE PURLIN building, use two levels to meet in the middle to determine apex. DIRECTIONS Install the Ridge Cap 1.
  • Page 59 STEP 41 REQUIRED PARTS (4) TRIM17 (4) TRIM18 FAST23 ACC51 ACC53 TRIM18 RAKE TRIM END CAP TRIM17 RAKE TRIM TRIM17 WALL PANEL PURLIN DIRECTIONS Install Rake Trims 1. Install the TRIM17 with TRIM18. TRIM17 may need to be cut to match panel length. Hide cut edge at top of ridge. a.
  • Page 60 STEP 42 REQUIRED PARTS (2) TRIM19 FAST20 TRIM19 PEAK BOX DIRECTIONS Installing the Peak Box 1. Install each TRIM19 with pop rivets or lap fasteners into the rake trim. (do not overtighten) 2. Remove any excess shaving from the roof panels to ensure shavings are not left behind that might create rust. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 61 STEP 43 ENJOY YOUR COMPLETED BUILDING Your building is fi nished. Take a break, relax, and fi nd a way to payback the friends who helped. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 •...
  • Page 62: Parts List

    PARTS LIST OPTIONS Most options both remove and add parts. The following tables list the parts adjustments that are made with each option. Please refer to images at front of assembly instructions if necessary. ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY LENGTH Wainscot Option...
  • Page 63: Parts List

    PARTS LIST OPTIONS ASSEMBLY PART # MANUFACTURER PART # DESCRIPTION QUANTITY LENGTH Gutter Option The following items are added TRIM33 GU142 Gutters 14' 2" TRIM34 DK102 Downspouts 10' 2" TRIM35 Gutter Straps TRIM36 DSS2 Downspout Strap TRIM37 Gutter End Cap TRIM38 Outside Corner Box Remove Endwall Framed Opening Option...
  • Page 64: Wainscot

    WAINSCOT OPTION PURLIN37 REQUIRED PARTS PURLIN38 (4) PURLIN36 (1) PURLIN38 PURLIN37 (3) PURLIN37 FAST12 PURLIN37 PURLIN36/37/38 WALL PANEL PURLIN36 TRIM31 WAINSCOT TRIM WALL GIRT DIRECTIONS WAINSCOT PANEL Install the PURLINs 1. Install PURLIN36 on the sidwalls. 2. Install PURLIN37 and PURLIN38 on the endwalls. 3.
  • Page 65 WAINSCOT OPTION PANEL34 PANEL33 PANEL32 PANEL31 PANEL30 PANEL29 PANEL29 PANEL20 PANEL34 PANEL33 PANEL32 PANEL31 PANEL30 PANEL29 PANEL29 PANEL20 PANEL 20 DIRECTIONS Install the Wainscot Lower Panels Follow the diagram Step 32 through step 35 from standard instructions to install PANEL20 onto the lower section of wall panels.
  • Page 66 WAINSCOT OPTION REQUIRED PARTS TRIM31 TRIM32 FAST3 CAUTION To prevent rust, PURLIN36/37/38 PURLIN36/37/38 WALL PANEL leave a 1/8" space between the wainscot trim and upper TRIM31 wall panels. TRIM31 WAINSCOT WAINSCOT TRIM TRIM WALL GIRT WALL GIRT DIRECTIONS WAINSCOT PANEL Install the Wainscot Trim Install the TRIM31 and TRIM32 wainscot trim on to the 3'6"...
  • Page 67 WAINSCOT OPTION PANEL11 DIRECTIONS Install Wainscot Upper Wall Panels 1. Follow Step 32 through step 35 to install wall panels on to the upper section of wall. Fasten bottom of panel to PURLIN36/37/38. Follow diagram on STEP 31. Be sure to leave 1/8" space between wainscot trim and upper wall panels to prevent rusting &...
  • Page 68: Remove Or Add Endwall

    REMOVE ENDWALL OPTION DIRECTIONS Remove Framed Opening in Endwall Option 1. When assembling columns H and I in step 11 and 12, use all FAST54, rather than a mixture of FAST54 and FAST46. 2. Repeat steps 6-8 to install wall girts similar to other endwall erected in steps 6-8. C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .
  • Page 69 ADD ENDWALL OPENING OPTION DIRECTIONS Endwall Framed Opening Add Option Note: This diagram and instructions is showing adding an endwall opening with both headers being at the 8' height. If your endwall opening is 10' on both ends then you only need to use (1) PURLIN34 and do not need the additional PURLIN32 as shown in this drawing or the erection drawings.
  • Page 70: Gutters

    GUTTERS OPTION ROOF PANEL CLOSURE GUTTER STRAP GUTTER EAVE STRUT TRIM37 WALL PANEL GUTTER END CAP TRIM14 Tip: If multiple gutter sections are required to meet the building's length, then sequential gutter(s) will nest inside of the previous gutter's end approximately 4" with a small bead of sealant (ACC52). Fasten the sequential gutter to the previous gutter using FAST20 or FAST23 fasteners then continue until you have fully covered the length of your building, trimming any excess gutter to allow the fi nal gutter end to align with the endwall steel line.
  • Page 71 GUTTERS OPTION DIRECTIONS DIRECTIONS Installing gutters Note: TRIM38 will be need to be installed after Rake trim (TRIM17) is installed in future steps. 5. With gutters now hung, identify the location of downspouts. Downspouts will typically be placed on each end of the building's gutter. The exact location can very (6"-14", but is recommended to position the downspout directly centered over a wall rib, which will allow for a vertical and level downspout once installed.
  • Page 72: Add Sidewall Opening

    ADD SIDEWALL OPENING OPTION Note: Optional sidewall opening can only be 9’ wide. PURLIN30 PURLIN43 PURLIN51 PURLIN42 PURLIN51 Sidewall Framed Opening add Option You will have fl exibility to install this opening in any sidewall bay that suits your needs for every sidewall framed opening section.
  • Page 73 SIDEWALL OPENING OPTION PURLIN30 PURLIN30 PLATE46 PLATE46 PLATE35 PURLIN42 PURLIN42 Figure 1 - for 7' , 8' and 9' door height Figure 2 - for 10' door height DIRECTIONS Note: At this point the bases of your jambs are not attached to the concrete. This is fi ne, as the next step will ensure every connection has been done correctly for your framed opening.
  • Page 74 NOTES C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C . E f f e c t i v e 0 1 / 2 0 2 1 • I n f o r m a t i o n s u b j e c t t o c h a n g e...
  • Page 76 Copyright © 2021, Central States Manufacturing, Inc., All Rights Reserved.

Table of Contents