5.2.4 How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
• By using the CLEAR command in the SAM menu
• By using the CLEAR command in the Factory mode:
• By using the following key sequence on the remote control transmitter: "062599" directly followed by the OK button.
• If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note: If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.
5.2 Panel Code
Press the following key sequence on a standard RC transmitter: "062598" directly followed by MENU and "xxx", where "xxx" is a 3 digit decimal value
of the panel type: see column "Display Code" in below tab. After resetting the Display Code, restart the set immediately.
CTN_ALT BOM#
24PFS5603/12
24PFT5603/05
24PFT5603/12
32PFS5603/12
32PFT5603/05
32PFT5603/12
Panel Type
TPM238WF1-LF1L0.Q S1G
TPM238WF1-LF1L0.Q S1G
TPM238WF1-LF1L0.Q S1G
TPT315B5-FHBN0.K S49P0L
TPT315B5-FHBN0.K S49P0L
TPT315B5-FHBN0.K S49P0L
Display Code
5
5
5
6
6
6