SCANNER MAINTENANCE
There are two distinct cleaning procedures for the M500 scanner that completes two separate functions:
The first procedure involves a special cleaning card that we offer either in singles or in bulk. The card is saturated,
presumably in an alcohol solution and is meant to clean the rollers and magnetic stripe reader head. These are surfaces
that are in direct contact with the IDs that are scanned and the rate of soiling of these surfaces depends on the average
cleanliness of IDs scanned as well as the scan volume. One uses the card by simply inserting it into the M500; the rest is
automatic. We recommend that this is done monthly in step with the monthly updates; however, depending on scan
volume, this is not strictly necessary. If you scan much more than 10,000 IDs a month and especially if you approach
20,000 scans a month, the cleaning should be completed monthly. Otherwise it can be done roughly every two to three
months.
The second procedure is somewhat more complex and requires three items. These items are a calibration card, an air
divider (a specially-made plastic tool) and an aerosol can of electronics duster. This procedure cleans the mirrors that are
located on the sides of the ID card slot. The instructions for this procedure are detailed below with pictures included.
The particularly tricky part, at least the first time someone does it, is getting the air divider in place. Our best piece of
advice is to look closely at the photos in the manual and realize that the tool will almost "snap" into place when inserted
properly. The calibration card and air divider are replaceable; however, you should take care to keep them in good
condition and avoid misplacing them. The calibration card should be put into its protective sleeve when not in use and
should be disposed of when it becomes at all scratched or dirty. This process is also recommended to be completed
monthly though if horizontal streaking is noticed in the scanned image, someone should complete the procedure
immediately. If some types of debris are left in place on the mirrors, they may become adhered and therefore difficult to
remove through normal methods.
The
package contains both a cleaning card and a calibration card. We have also included your first cleaning kit free
M500
of charge. This kit consists of two more cleaning cards, another calibration card, an air divider tool and one can of
Ultrajet 70 aerosol duster. You don't strictly need to use Ultrajet 70 though it is recommended. The duster you use must
be free of residue and preferably not be flammable. There are other brands that meet these criteria; however, we have
not found them to be roughly the same cost as Chemtronics Ultrajet 70. Please do not use the kind that cost $5-$10.
Cleaning Procedure for
M500 Scanner

Advertisement

loading

Summary of Contents for E-Seek M500

  • Page 1 IDs that are scanned and the rate of soiling of these surfaces depends on the average cleanliness of IDs scanned as well as the scan volume. One uses the card by simply inserting it into the M500; the rest is automatic.
  • Page 2 Dust lines / yellowing at top of image...
  • Page 3: Calibration Card

    The main Purpose of the White Calibration Card is to perform a white color balance calibration. This calibration occurs when the Calibration Card is inserted into the with the ARROW FACING IN towards the M500. (See the M500 Calibration Card illustration below) . When this Calibration process is performed, an EV_WHITE_CAL event will occur, which will cause certain settings to be calculated and stored within the .
  • Page 4 The cleaning card is designed to clean the internal rollers and the Magnetic Read Head inside the . The need for M500 cleaning varies, but is primarily dependent on the usage or the number of card scans. The general guideline is for cleaning once a month for high usage and once every three months for low usage environments.
  • Page 5: Air Cleaning

    M500 1. Calibration Card, this card is designed and made by E-Seek, Item # M500-CALIB. 2. M500 path Air Diverter, a plastic part made to block the scan path and divide the air flow, Item # M500- AIRDV. Air Diverter...
  • Page 6 3. Air Duster, aerosol can of compressed air. The preferred air duster is designed to leave no residue with a high filtration. The non-flammable model of the product is preferred. The following Brand has been used and tested by E-Seek. Chemtronics Ultrajet 70. https://www.chemtronics.com/p-844-ultrajet-70.aspx There are three parts to maintain the M500: Verification (Step 1-2) Cleaning...
  • Page 7 Step 2: Verifying that the dust/debris exists on the mirrors. Calibration card Image from application Note the horizontal dust lines at top of the card If there is dust on the mirrors, you will see a dust line (as illustrated by the number 1 on the figure below) on the left section (number2) of the image.
  • Page 8 3. Align the Air Divider to the M500 side wall. 4. Push the Air Divider completely into the M500 Scan path. Step 4: Use of the Air Duster. Insert the pressurized Air Duster nozzle into the M500 scan opening. Air Duster operation Follow the operational directions on the Air Duster for use.
  • Page 9 At this time ignore the Right side image. Step 6: Calibration. At this point you need to calibrate the M500 without any dust present on the mirrors. This is a simple and mostly automatic process. Simply insert the Calibration Card into theM500 with the arrow FACING INWARD.