Yates Y-530 User Manual

Portable thermal detector

Advertisement

Quick Links

Y- 530
PORTABLE THERMAL DETECTOR
Yates Protect Y-530 User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Yates Y-530

  • Page 1 Y- 530 PORTABLE THERMAL DETECTOR Yates Protect Y-530 User Manual...
  • Page 2: Table Of Contents

    Y- 530 PORTABLE THERMAL DETECTOR Table of Contents Product Introduction ........................3 Product Highlights ........................4 Product Features ........................5 Product Familiarization ........................ 6 Basic Operation .......................... 7 Startup............................. 7 Shutdown ..........................7 View version number ......................7 Check the device ID ........................ 7 How to change the temperature settings ..................
  • Page 3: Product Introduction

    Y- 530 PORTABLE THERMAL DETECTOR Product Introduction This unique thermal-detector can detect human body surface temperature from a safe distance and without physical contact. This method helps prevent the spread . of infectious diseases. This system uses the highest quality and most precise temperature sensor on the market today. In addition to a green light signifying in-range temperatures and a red light indicating out-of- range body temperatures, this system also uses voice warningsThese voice warnings can be customized to your desired language.
  • Page 4: Product Highlights

    Y- 530 PORTABLE THERMAL DETECTOR Product Highlights Human Body Temperature Screening • Dynamically monitor and screen human body temperature • Infrared monitor takes precise temperature measurements • Built-in high-precision miniature monitor High-quality Components • Highly accurate and reliable with stable performance. Modular Component Design •...
  • Page 5: Product Features

    Y- 530 PORTABLE THERMAL DETECTOR Product Features Quick Screening • Easily and actively collect infrared temperature data • Human operator NOT required for temperature measurement • Temperature measurement completed in less than one second Non-contact Temperature Measurement: • The infrared temperature sensor allows no contact temperature reading •...
  • Page 6: Product Familiarization

    Y- 530 PORTABLE THERMAL DETECTOR Product Familiarization Temperature Display • Easy-to-read, clear and bright digital display shows the temperature value in real time Visual Notification • Green light for a normal temperature range of 95°F – 98.6°F (35°C-37°C) • Red light for temperatures outside of the normal range of 95°F – 98.6°F (35°C-37°C) Distance Sensor •...
  • Page 7: Basic Operation

    Y- 530 PORTABLE THERMAL DETECTOR Basic Operation Startup • Connect power • Press the POWER button to start the system; the device will display 0 Shutdown • Press the POWER button to power off the system To view the version number of the program •...
  • Page 8: Enter The Device Password

    Y- 530 PORTABLE THERMAL DETECTOR How to Change the Temperature Settings These instructions show how to change the ambient and alarm temperature settings if necessary. NOTE: All temperature settings are displayed in Celsius by default. The factory settings should work under most conditions and should not need to be changed. Factory Settings •...
  • Page 9: How To Change The Temperature Settings

    Y- 530 PORTABLE THERMAL DETECTOR To change the temperature settings after entering the password 1. Press the ENTER button 2. Press the SELECT button to shift to the alarm or ambient temperature setting 3. After adjusting the setting, press the ENTER button to return to the main screen How to change the device language 1.
  • Page 10: How To Change The Voice Volume

    Y- 530 PORTABLE THERMAL DETECTOR How to change the voice volume 1. Press the ENTER button 2. Press the SELECT button to shift 3. Press the ADJUSTABLE button to adjust the number 4. Input the number 1111 5. Press the ENTER button. The display shows 0000 Press the CONFIRMATION key and the display will show FFFF.
  • Page 11: How To Set An Id Number

    Y- 530 PORTABLE THERMAL DETECTOR a. Reserved function = How to set an ID number NOTE: Setting the ID number is only needed when adding the optional LAN network function. 1. Press the ENTER button 2. Press the SELECT button to shift 3.
  • Page 12: Installation Note

    Y- 530 PORTABLE THERMAL DETECTOR 5. Press the ENTER button. The display shows FFFF to indicate factory settings have been restored 6. Press the ENTER button to return to the main screen Installation Note For best results, we recommend installing this equipment in an indoor area free from wind. A cold wind from outside might influence the temperature readings.
  • Page 13: Technical Specifications

    Y- 530 PORTABLE THERMAL DETECTOR Technical Specifications Product weight: 1.3 lbs. [0.6kg] Power consumption: <8W Working temperature: 14°~ 104° F [-10°~40°C] Operating humidity: 95% [non-condensing environment] External power supply: AC 100-240V, 50 / 60Hz Working voltage: 12V Temperature measurement speed: <1 second Temperature measurement accuracy: ±...
  • Page 14: Disclaimer

    Y- 530 PORTABLE THERMAL DETECTOR Disclaimer The infrared temperature measuring device is the human body surface temperature screening instrument. The test results indicate the real-time temperature evaluation of objects or people in a specific environment. The selling company and the manufacturer shall not bear any responsibility for the direct or indirect loss caused by the use of these test results.
  • Page 15 Y- 530 PORTABLE THERMAL DETECTOR We welcome your comments and suggestions on how to improve our products.