    6.6.3 Use 
2
Read E
PROM's specific area as unit of 128(80h)‐byte. ( 84h ) 
6.6.4 EDID Write 
  EEPROM access by using DDC2B protocol 
1‐Byte write   
START
A0
 
    L :    0x00~0x7F 
        D :    data 
8‐byte write   
START
A0
 
        L : 0x00,0x10,....0x70 
6.6.5 EDID Read 
DDC2B Command.(A0/A1) 
START
A0
 
 
      ‐ 128 Byte transfer of EDID Buffer of    MICOM 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A
L
A
D
A
A
L
A Data1 A
 
A
00
START
A1
 
80 
A4 
 
80 
A6 
 
80 
A8 
 
80 
AA 
 
80 
AC 
 
80 
AE 
 
80 
STOP
....
A
A
Data8
A
Data1
. . .
- 15 -
Copyright ©
Only training and service purposes.
1‐Page    80~FF    Read 
2‐Page      0~7F    Read 
2‐Page    80~FF    Read 
3‐Page      0~7F    Read 
3‐Page    80~FF    Read 
4‐Page      0~7F    Read 
4‐Page    80~FF    Read 
5‐Page      0~7F    Read 
5‐Page    80~FF    Read 
6‐Page      0~7F    Read 
6‐Page    80~FF    Read 
7‐Page      0~7F    Read 
7‐Page    80~FF    Read 
STOP
Data128 A
CS
A
LG Electronics Inc. All rights reserved.