Download Print this page

Data Logging - DGSI VW MiniLogger User Manual

Advertisement

Overview
Connect the Sensor
VW MiniLogger, 2018/8/24
Connect the sensor to the MiniLogger.
1.
Insert new batteries, if necessary.
2.
Check the MiniLogger's settings.
3.
Remove the MiniLogger's lid.
1.
Prepare to insert cable through the cable gland: remove the
2.
nut, the nylon washer, and the rubber compression sleeve.
Earlier models of the MiniLogger do not have the nylon
washer. Slide the nut, nylon washer, and rubber compression
sleeve onto the sensor's signal cable
Insert the cable through the cable gland and connect the wires
3.
the MiniLogger's terminals as explained below.
Function
Wire Color
VW
Orange
VW
White & Orange Black
Shield (Drain)
Bare wire
Temperature
Blue
Temperature
White & Blue
Pull gently on the wires to check the connection.
4.
Slide nut and rubber compression
sleeve onto cable. Then insert
cable into box.

Data Logging

Alt Wire Color
Red
Bare wire
White
Green
Connect leads from the cable
to the terminals:
VW VW Shield Temp Temp
12