Contact Insertion into Molex Connector Housing

(1)
After the contact terminals have been installed on the wiring harness, the contact
terminals can be inserted into the proper location in the connector housing (P/N 030-
01094-0066). The terminal cannot be inserted upside down. Be sure to push the
terminal all the way in, until a click can be heard or felt.
(2)
The self-locking feature can be tested by gently pulling on the wire.
2.3.6.4

Extraction of Contact from Molex Connector

(1)
Slip the flat narrow blade of a Molex contact ejector tool, HT-1884 (Honeywell P/N
047-05099-0001), under the contact on the mating side of the connector. By turning
the connector upside down one can see the blade slide to the stop.
(2)
When the ejector is positioned against the stop the locking key of the contact is
raised, allowing the contact to be removed by pulling moderately on the lead.
(3)
Neither the contact or position is damaged by removing a contact; however, the con-
tact should be checked visually before reinstalling in connector, to be certain that re-
taining tab "A" extends as shown (see Figure 2-1) for retention in connector.
2.3.7

POSITRONIC CONNECTOR ASSEMBLY PROCEDURE

Assemble the Positronic connector using the procedures detailed in figure 2-2.