Common Common Common Problems Problems - 3One data 7304 User Manual

V.35 optic fiber modem
Hide thumbs Also See for 7304:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
6. 6. 6. 6. Common
Common
Common
Problems
Problems
Common Problems
Problems
No. Failure
1
PWR
power
supply
indicator
lamp
not
lightening
2
LOF
out-of-frame
alarm lamp lightening
3
LOS data loss alarm
lamp lightening
4
TXD
lamp
not
lightening
Common
Failures
and
Common
Common
Common Failures
Failures and
Failures
and
and Solutions
Cause
1.Power supply not properly
connected
2.Protector tube damaged
3. -48V DC input tie-line in
reverse connection
4.Internal power supply circuit
with failure
1.Optic interface not clean
2.Optic fiber not well inserted
3.Wrong clock setting
4.Time slots of the devices at
two ends not conformance
5.Internal circuit damaged
1. Optic fiber in wrong
interconnection
2.Optic fiber not well inserted
3.Optic fiber broken
4.Internal circuit damaged
V.35
interface
not
well
connected or the router etc. not
turned on.
Page 11 of 11
MODEL7304 User Manual
Solutions
Solutions
Solutions
Solution
1.Check
power
switch
2.Replace protector tube 3.Correct -48V
power supply line connection
4.Returned to the manufacturer for
repair.
1. Clean the connector of optic interface
2. Insert the SC connector in place
3. Refer to the description on rear panel
4. Returned to the manufacturer for
repair.
1. Correct the connection
2. Insert the SC connector in place
3. Check optic cable
4. Returned to the manufacturer for
repair.
1. Check the connecting line and
terminal device