Elmo 10ASBOX Technical Manual

1 output analogue addressable module

Advertisement

Quick Links

www.acornfiresecurity.com
CPD certification
n° 0051 - CPD - 0276
1 Output Analogue Addressable Module
1OASBOX
TECHNICAL MANUAL
www.acornfiresecurity.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10ASBOX and is the answer not in the manual?

Questions and answers

Summary of Contents for Elmo 10ASBOX

  • Page 1 www.acornfiresecurity.com CPD certification n° 0051 - CPD - 0276 1 Output Analogue Addressable Module 1OASBOX TECHNICAL MANUAL www.acornfiresecurity.com...
  • Page 2 www.acornfiresecurity.com 1OASBOX - TECHNICAL MANUAL FOREWORD FOR THE INSTALLER: Please follow carefully the specifications relative to electric and security systems realization further to the manufactu- rer’s prescriptions indicated in the manual provided. Provide the user the necessary indication for use and system’s limitations, specifying that there exist precise specifi- cations and different safety performances levels that should be proportioned to the user needs.
  • Page 3 www.acornfiresecurity.com TECHNICAL MANUAL - 1OASBOX 1. GENERAL 1OASBOX module has been designed for advanced fire detection systems managed by FX/50, FX/20 and FX/ 10 control panels (and other compatible) equipped with loop operating with AS protocol; it is equipped with 1 relay output.
  • Page 4 www.acornfiresecurity.com 1OASBOX - TECHNICAL MANUAL 4. OVERVIEW AND WIRING DIAGRAM WARNING: during wiring and installation procedure, make sure panel and loop are disconnected from power. WARNING Automatic activation function upon power failure is not active: the relay will not activate when the panel is switched off for maintenance sessions.
  • Page 5 www.acornfiresecurity.com TECHNICAL MANUAL - 1OASBOX 5. ADJUSTMENT OF RELAY OUTPUT OPERATING MODE Steps to adjust the output relay function in order to set automatic activation in case of power failure: - open module housing: carefully open the side fixing clips; - cut the coloured jumper wire on the left side of the microprocessor;...
  • Page 6 www.acornfiresecurity.com 1OASBOX - TECHNICAL MANUAL 7. ID ADDRESS SETUP The setup procedure of 1OASBOX module ID address is very easy: it is equipped with three rotary dip switches corresponding, respectively, to hundreds (x100), tens (x10), and units (x1) of the code to set. Please consider that code setup is fundamental for the correct identification of the module from the control panel;...
  • Page 7 www.acornfiresecurity.com TECHNICAL MANUAL - 1OASBOX 8. FUNCTIONS SETUP To setup module functions, use the dipswitch indicated in “OVERVIEW AND WIRING DIAGRAM” on page 4. Functions are listed in the following table: Dip Switch Position Function Not used. Not used. Relay output contacts are free from potential (set dip switch 5 and 6 to OFF) Relay output is set to control optical-acoustic devices over supervised control line...