Microprocessor based control units modd. ET8/480, ET8/480S and ET8/480PT postal version TECHNICAL MANUAL...
Page 2
Some products incorporate rechargeable or non rechargeable batteries as emergency power supply. Their wrong connection may damage the product, properties and the operator’s safety (burst and fire). YOUR DEALER: 2 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
1. GENERAL INFORMATION The ET8/480, ET8/480S and ET8/480PT model of microprocessor based control units have been designed in order to enable the installation of high quality intrusion detection in residential homes, businesses, bank branches, post offices, etc. it is possible also to create multi-istallation systems with up to four separte zones and a maximun of 80 double ba- lanced inputs.
3. GENERAL FEATURES For an accurate appraisal, the features of the ET8/480, ET8/480S and ET8/480PT models of control units are as follows: - Control unit managed by microprocessor for high risk applica- - Programmability of communications parameters tions used in residential housing, banks, post offices and busi- according to CEI 79-5 and CEI 79-6 protocols;...
C11K, especially when the control unit is used with several keyboards, transponders and volumetric sensors. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 5...
ET8/480, ET8/480S and ET8/480PT models of control unit are compliant with CEI 79-2 standard is the level of performance declared. They resulted immune to radio-frequency and voltage pulses to the mains supply terminals; tests have been carried out according to IEC 801-2-3-4. They are also compliant with the 89/336/EEC directive relative to electromagnetic compatibility and the 93/68/EEC directive relative to low voltage safety.
Page 7
12 - Proceed M4 keys memorization to the pertinent keyboards. 13 - Test the system. 14 - Connect the sirens and carry out a final test. 15 - Close the control unit up using the screws provided. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 7...
Y = RESET push-button for resetting the operations to be used solely with ET8/48S control unit or returning to factory status, control unit. DEFAULT. These operations described in the pertinent section. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 9...
Page 10
(LA and LB) and the output terminals (LA’ and LB’). To the earth terminal connects the standard protections of the telephone interface. Make the connection to an effecient earth. 10 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
8. ELECTRICAL CONNECTIONS 8.1 Connection of double balanced inputs Main diagram for double balanced connection 8.2 Connection of control unit TAMPER input Main diagram for single balanced connection of system TAMPER protection input. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 11...
Note: The external source enabling command must be given as impulse by using a device of the same level or higher installed inside the control unit housing and connected to an appropriately programmed line. 12 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
8.5 Connection of the transponder Main diagram for transponder connection. NOTE: The use of CP8/TRS mod. transponders is not certificated by IMQ-SISTEMI DI SICUREZZA. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 13...
Page 14
Diagram of addresses programming for the CP8/TR transponders. 14 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
Page 15
Diagram of addresses programming for the CP8/TR8 AND CP8/TR8B transponders. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 15...
Page 16
Connection of transponders mod. TR9000, TR9000S and DF9000. NOTE: The use of TR9000 and TR9000S transponders is not certificated by IMQ-SISTEMI DI SICUREZZA. 16 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
Page 17
Diagram of TR9000, TR9000S transponders and DF9000 sensor’s addresses programming. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 17...
CP8/TRS and TR9000S. For MFT outputs programming and DEFAULT configurations, consult the specific programming section in the technical manual. 18 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
8.10 Control devices Main connections of a system divided up into four zones with the keyboard of the ET8/480 control unit used as supervi- sion. Note: From the connection of a second keyboard up to the wiring of the maximum number of control points, it is advisable to use an auxiliary mains supply box in order to increase the autonomy of the system.
Page 21
Connection of a NADIR keyboard Connection of AURORA keyboard ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 21...
Page 22
Connection of a ZENITH Key point Connection of the reader to the keyboard of the ET8/480 control unit. Connection of the 2000 model I6 or I7-type readers 22 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
The most interesting aspect is represented by the possibility of installing an optional voice synthesis card for regis- tration and voice synthesis message listening, model SK/VOICE, by means of which two messages can be sent to up to 12 telephone network subscribers. Connection of the SK/VOICE card. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 23...
Page 24
Telephone connection example. NOTE: PTN filter is no certificated from IMQ-SISTEMI DI SICUREZZA. Example of direct programming from PC 24 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
View of the keyboard built into the front of the ET8/48 keyboard. The ET8/48S only has remote keyboards and the ET8/480PT control unit is equipped with NADIR keyboard mounted on internal door. 9.2 Nadir keyboard View of NADIR control keyboard ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 25...
Page 26
View of the AURORA control keyboard View of ZENITH Key point 26 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
10. GENERAL RESET 10.1 Reset operations The ET8/480 control unit comes equipped with factory-set programming entitled DEFAULT which enables a minimum of functions so as to be able to conclude the required programming operations. Should it become necessary to cancel the programmings carried out, it is possible to return to the DEFAULT settings by operating in the following manner: - A = Open the housing of the control unit.
"PROMPT" or "WELCOME MESSAGE" is defined the standard visualization with system in rest and no anomalies. The second line can be customized with the installer name, for example: VE25/01/03 20:45 ACME SECURITY 11.2 Led visualization Command devices LED warning lights defined as system and area terminals 28 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
In the event no choice is made, the command is ignored. The EURO-type command cannot be utilised with operations carried out on the I6 and I7-type remote readers. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 29...
The illustrations below depict the key sequences, called MODE x, used in order to input or change the values of the indi- vidual menus or change the choices displayed. Mode A Used for inputting individual values of a numeric nature (range 0-255). Mode B Used for modifying the options 30 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
Page 31
Mode used for the self-learning of the PIT proximity keys to be associated with the various users (one key per user). Mode G Used for inputting the sectors S1 - S4 associated with a zone managed by individual user. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 31...
Page 32
Used for modifying the messages Mode I Used for changing the hexadecimal codes Mode J Used for changing the date displayed and the time of the internal clock and for scrolling through the various menus. 32 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
13. CONFIGURATION MENU List of the principal configuration menus of the control unit: The ET8/480 control unit is structured in order to enable access to two programming menus denominated: ACTIONS and CONFIGURATION In the following table, the sub-menus available are listed:...
Press Yes to procede and have below’s. The three main icons stand for: Serial communications Opening of file to be Activation of firmware port choise. downloaded in the control downloading procedure. panel’s memory. 34 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
Page 35
"CONFIGURAZIONE OPZIONI SISTEMA" menu. Press Key and downwords arrow key to enter "Aggiorna release" menu last press . key as indicated below. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 35...
Page 36
- The browser is able to convert the old configuration to a format compatible with version 2.0. Select Action Menu Conversion File 1.x -> 2.0 . - After the conversion, connect to the browser. At last download the control unit’s confi- guration for system management. 36 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
Page 37
The program will convert the file to a format compatible with the control unit’s current version, only by selecting OK. At the end of the operation, indications useful to the following programming activities will be displayed. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 37...
"PROMPT" or "WELCOME MESSAGE" is defined as standard visualization with idle system in rest and no anomalies.The second line can be customized with the installer name, for example: VE05/01/01 20:45 ACME ET8/480 1.0 16.1 Disabling from keyboard 16.2 Enabling from keyboard 16.3 Disabling through electronic key 38 - ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL...
16.4 Enabling through electronic key 16.5 Enabling in MAXIMUN SECURITY mode. 16.6 Disabling the system in MAXIMUN SECURITY mode via keyboard User non authorized to "MAXIMUN SECURITY" mode Non permitted action ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 39...
Refer to the complete programming manual included in the attached CD for programming details. The CD also contains WABL0032/CD LIGHT programming software required for fast programming by PC in direct connection with control unit through CP8/SER2 optional cable. ET8/480, ET8/480S and ET8/480PT - TECHNICAL MANUAL - 51...
Keep into account that Nichel Cadmio battery has a life of 10 years over which the functioning cannot be granted. See to its replacement at any ELMO's technical service point in order to avoid incorrect visualizations and functioning.
9.1. Front keyboard of ET8/480 model control unit ....... . .
Page 56
Microprocessor based control units modd. ET8/480, ET8/480S and ET8/480PT postal version - v. 1.0 r. 2.0 - TECHNICAL MANUAL FEBRUARY 2003 This information and characteristics of the products as described above are not binding on the manufacturer and may be altered without notice.