G38xx14 Configuration Software NTRODUCTION The G38xx14 program has been designed for configuration of the G38900014 master generator. All functions in the generator are represented by graphic symbols. To each channel function are related parameters and comments, which can be edited locally in the PC and transferred to the master generator through RS232.
Page 3
Write data to the Generator Read Generator: Read data from the Generator Print: The following options are available: Print-out of: Address Listing Master Channels Real time Channels or Logic Settings SMS Setup 2001 Carlo Gavazzi Industri A/S. All rights reserved.
You can select 3 preferred languages or select other languages to be immediately available in your View-Language menu Serial port: Selection of Com 1 or Com 2 port, for connection of the G38900014 generator Help menu General information: You can call the Help menu at any time by pressing F1...
Page 5
Furthermore, channel function can be selected by clicking on different letters. To be able to select functions by clicking on letters, click on the Title bar. The letters and the related channel functions can be seen by clicking F1 for help: 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 6
G38xx14 Configuration Software Tool tip When the curser is positioned on a channel button, a bar appears indicating channel number, describing channel type and showing the user-defined channel description. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
The text window is for entering general information, eg name of user, date of configuration, etc. By clicking in the first checkbox, time and date is transferred from the PC to the G38900014. The program shows the updated time and date from the Windows System for checking. If the PC does not show the correct time, the clock can be adjusted in the usual way, ref.
Page 8
Edge triggering is possible. < / > means triggering on the leading edge, while < \ > means triggering on the trailing edge of a given address. The edge sign toggles on pressing < / >. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 9
For every channel type there is a field for user description. Blank channels do not require any parameters. For a monostable channel, the function can be inverted, and for a bistable channel, it is selected whether the channel is to be used in the Intruder alarm. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Entering of Off-delay Additional channel with which the function is enabled When the timer function is changed, the icon of the channel button is also changed. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 11
Sundays Disabled since no time has been defined for neither switching on nor switching off Editing of real-time channels. Use the Right- and Left-keys to move the cursor within the lines. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
When the properties window is active, the master function can also be edited by means of the arrow keys and the keys 0, 1 and X. Activate F1 for additional help on this function. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 13
Master function channels consist of both an Up-channel and a Down-channel. Operating the master up will cause all roller blinds comprised by this master to start moving up. Either simultaneously or one by one with 2 secs intervals (sequentially). 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Intruder alarm Number of allowed pulses within a 10 secs time frame before the motion detector gives out its alarm signal 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 15
Entry of On- ISA Operation mode delay after either Standard or which the alarm Auto-reset. is activated In Auto-reset mode the Reset channel cannot be selected 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 16
Disable channel, the smoke alarm detector is removed are designed from the alarm identically surveillance Only one Alarm siren and one Alarm signal channel can be selected for the water alarm 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Insert flash interval Click here to call a matrix in which the desired channels are selected 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 18
G38xx14 Configuration Software Common siren Selection of alarms using common siren The set siren time applies to this channel only. The times are identical with the times specified under the individual alarms 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 19
Channel controlled by a timer. When transmission takes place on this channel, the receiver will turn on and off at the specified time intervals. Parameters: Hours, minutes, seconds from 0,0,0 to 99,59,59. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
The channels controlled by a master function will perform their individual functions as if transmission had taken place on the channel. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 21
Assignment of an address or flag by which the up-direction or the down-direction is given priority. A priority signal blocks all other control signals for the motor. The selected channel must transmit a continuous signal for the duration of the priority. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Sensor input range Input range min and max defines the range of values for the used analink input. For many sensors, the measuring range is preset and cannot be changed. Limit values 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 23
The motion detector can serve as an alarm sensor in the Intruder alarm. When this option is selected, a field appears for setting the no. of allowed pulses within a 10 secs time frame, before the motion detector gives out its alarm signal. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 24
None. Reset Operation: Resets any Acknowledged failures and turns off the Siren. Parameters: None. Lamp Test Operation: While activated, all detector input channels are turned on (Mimic display test). Parameters: None. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 25
(0 ... 30 min) has expired. Under normal operation the channel is off. The channel does not react on a transmit pulse. Activation through logic will pulsate the output. Parameters: Activation time 0 to 30 min. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
If the alarm disappears, the alarm automatically resets the siren time and alarm signal time. • Upon start of the G38900014, the Reset channel is activated and the water alarm only starts at the end of the reset time. •...
Page 27
• If the alarm disappears, the alarm automatically resets the siren time and alarm signal time. • Upon start of G38900014 the Reset channel is activated and the smoke alarm only starts at the end of the reset time. •...
Page 28
Activation through logic will activate the output. Parameters: Alarm signal delay 0 to 10 min. Note: The siren is stopped by deactivating the alarm in the same as the alarm was activated. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 29
8. Upon a new or repeated alarm, the sequence described under item 5 is repeated. • Upon start of G38900014 the intruder alarm is switched off. • All channels in the intruder alarm can be activated/read by the logic functions.
Outputs a Multiplexing address on channels A1 to A4. Used to enable multiplexed Analog transfer. Parameters: Multiplexer Count (Off, 2,3 ..16), Multiplexer Delay (1,2,4..128). Configured under Basic set-up, as this function is fixed on channels A1..A4. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 31
Logic/Master. • In the intruder alarm the Manual-armouring-channel should be used as Disable channel. When this channel is read by the alarm detector inputs, the alarm Start/Stop signal is read. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
G38xx14 Configuration Software Data exchange It is possible to connect two channel generators G38900014 and transfer addresses from one network to the other. The configuration matrix <Two Dupline networks> is needed, when two Master Generators are connected via the communication cable. Entering “1” in the desired address performs selection of the channel-status from the other network.
Page 35
Example: The text in the Description field will be sent, when Dupline channel A1 goes ON. It is not allowed to use (,) in the text. 2000 Carlo Gavazzi Industri A/S. All rights reserved.
Page 36
1 common sirene (F3) 1 Reset button for reset of smoke alarm For activating the setup menu for SMS, you have to select the <SMS Setup> option in the <Basic Setup>: 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 37
SMS message An SMS message will be sent when the alarm, configured in channel E1, goes ON. It is not allowed to use (,) in the text 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 38
If more Dial-out Phone numbers has been setup, an acknowledge can be sent to the Master Generator by sending an empty SMS message back, and the Master Generator will then stop sending messages to the following phone numbers. SMS message sent to Master Generator. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 39
The actual channels can now be controlled via a SMS message by using the channel address or the Description of the channel: 2001 Carlo Gavazzi Industri A/S. All rights reserved.
NB: When using controlling commands on a channel, which is also configured to send a message when changing status, the message will also be sent to the GSM phone. Not all channel types can be controlled. 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 41
*2) Alarm detector is ON to indicate an alarm situation, irrespective of the input polarity. *3) Event caused by change of transmitter signal, NOT by output status as read by GTU 8 2001 Carlo Gavazzi Industri A/S. All rights reserved.
Page 42
On this channel type, an Off command may not ensure, that the channel output is turned OFF, as the output of the channel is also controlled by the transmission on the channel. Control of of this channel type is not allowed and will produce ‘Unknown or Illegal command’ 2001 Carlo Gavazzi Industri A/S. All rights reserved.