Download Print this page
Balluff BIS C-87 Series Technical Description, User's Manual

Balluff BIS C-87 Series Technical Description, User's Manual

Handheld programmer

Advertisement

Quick Links

_
BIS C-87
Handheld Programmer
Technical Description, User's Guide
english

Advertisement

loading

Summary of Contents for Balluff BIS C-87 Series

  • Page 1 BIS C-87 Handheld Programmer Technical Description, User's Guide english...
  • Page 2 www.balluff.com...
  • Page 3 5.1 Keyboard, display, and operating concept 5.2 Reading data carriers 5.3 Writing to data carriers 5.4 Editing data 5.5 Initializing data carriers 5.6 Lock 5.7 Working with files 5.8 Connecting the Handheld Programmer to a PC/laptop Technical data Appendix Index www.balluff.com...
  • Page 4 BIS C-87_ Handheld Programmer User instructions 1.1 CE Declaration of Declaration of Conformity Conformity and user safety This product was developed and produced in compliance with applicable European standards and directives. Note You can request a Declaration of Conformity separately. For additional safety instructions, refer to the "Safety"...
  • Page 5 1.6 Symbols Attention! This symbol indicates a safety instruction that absolutely must be followed. Note, tip This symbol indicates general notes. 1.7 Abbreviations Balluff Identification System Cyclic Redundancy Check EEPROM Electrically Erasable Programmable Read Only Memory Electromagnetic Compatibility Personal Computer...
  • Page 6: General Safety Notes

    You can also return the included batte- ries to the following address (with sufficient postage) after using them: Balluff GmbH, Schurwaldstraße 9, 73765 Neuhausen a.d.F., Germany Attention! Use only Balluff-approved power supplies.
  • Page 7: Getting Started

    The system components of the Handheld Programmer are powered by a 3.7 V rechargeable battery pack (Li-Ion). ► Please charge rechargeable batteries provided by Balluff before using them for the first time! Fig. 3: Connecting the power supply – Charging the battery pack Changing A rechargeable battery with high capacity has a battery life of up to 48 hours after a full charge.
  • Page 8 BIS C-87_ Handheld Programmer Getting started 3.2 Overview of WORKABOUT PRO C BIS C-870-1- 008-X-000 Fig. 4: Handheld Programmer BIS C-870-1-008-X-000 Ø > 20 mm Read/write head for BIS C data carriers with round coil Active surface (underside) BIS C-871-1- 008-X-000 Fig.
  • Page 9 Read/write head for BIS C data carriers with round coil Ø < 20 mm Active surface (frontside) BIS C-870-1- 008-X-002 Fig. 7: Handheld Programmer BIS C-870-1-008-X-002 Ø > 20 mm Read/write head for BIS C data carriers with round coil Barcode scanner Active surface (underside) www.balluff.com...
  • Page 10 3.6 Creating your Note own operating The BALLUFF.dll was developed as an independent software for creating a custom interface tailored operating interface, for the Handheld Programmer. The ordering code for this application is available on demand.
  • Page 11 Getting started ► 3.7 Starting the RFID On the Windows CE desktop, tap on application "Start > Programs > BALLUFF RFID > BIS C RFID" (depending on the Windows CE version, tap on the four-color Windows logo instead of ®...
  • Page 12 BIS C-87_ Handheld Programmer Getting started "Settings" tab The following settings can be made: continued CodeTag type Selection of the data carrier type. All or one particular data carrier type may be selected. Default setting BIS C-1xx-04 32-byte page size BIS C-1xx-05 BIS C-1xx-11 64-byte page size...
  • Page 13 Yellow flashing: Read/write head activated, waiting for data carrier. Green: Read/write operation successfully finished. Red: Read/write error occurred. Type Display of the data carrier type. Address Start address for reading or writing The start address can be entered or set using the spin box. www.balluff.com...
  • Page 14 BIS C-87_ Handheld Programmer Getting started Length Number of bytes you want to read or write. The number of bytes can be entered or set using the spin box. Format (Char, Byte, Hex, Bin) Selecting the display format for data. The data that were read are displayed according to the selection made in the selection field.
  • Page 15 A saved file can be selected and opened. The data are displayed on the "RW Data" tab. [Save] Opens the "Save file as…" dialog. The data (from the display field on the "RW Data" tab) can be saved in a file. www.balluff.com...
  • Page 16 BIS C-87_ Handheld Programmer Getting started "About" tab Display of the software version and manufacturer information. Fig. 15: "About" tab...
  • Page 17 Saving/loading files. Creating your Note own operating The BALLUFF.dll was developed as an independent software for creating a custom interface tailored operating interface, for the Handheld Programmer. The ordering code for this application is available on demand. 4.3 Control function The Handheld Programmer is the link between data carrier and controlling system.
  • Page 18: Basic Knowledge

    BIS C-87_ Handheld Programmer Basic knowledge 4.4 Data integrity In order to ensure data integrity, data transfer between the data carrier and processor must be Data check monitored using a check procedure. The factory default setting in the Handheld Programmer is for double reading with comparison. Alternately the CRC_16 data check can be selected.
  • Page 19: Memory Capacity

    This leaves 14 bytes per block available. The usable number of bytes can be found in the following table. Data carrier type Memory capacity Usable bytes for CRC_ 16 BIS C-1xx-04 511 bytes 450 bytes BIS C-1xx-05 1023 bytes 930 bytes BIS C-1xx-11 2047 bytes 1922 bytes BIS C-1xx-32 8192 bytes 7936 bytes www.balluff.com...
  • Page 20 The operating manual can be found on the included CD operating – Or on the Internet at: http://www.psion-teklogix.com concept ► Start Balluff RFID Reader. ► Make desired settings. ► Activate read/write head by tapping [Open reader]. ⇒ The settings are grayed out and the button changes to [Close reader].
  • Page 21 Hold the active surface to the data carrier you wish to read. ⇒ The data are read and displayed. The "Operate" field lights up green. ⇒ If there is a read error, the "Operate" field lights up red. Fig. 18: Write operation successful Fig. 19: Read operation failed www.balluff.com...
  • Page 22 BIS C-87_ Handheld Programmer Operation ► 5.3 Writing to data Switch to the "RW Data" tab carriers ► Select start address, number of bytes to read, and data format. ► Select the data record you want to write. ► Tap on [Write].
  • Page 23: Operation

    Tap on a data line in the display window. ⇒ The editor opens. ► Edit data using the keyboard and confirm with [OK]. ⇒ The editor is closed and the changed data are displayed. Fig. 23: Editing data carriers www.balluff.com...
  • Page 24 Switch to the "Settings" tab carriers The data carrier is programmed with 00 and thereby prepared for operation with a CRC data check. ► Start Balluff RFID Reader. ► Activate "Use CRC Check". ► Activate read/write head by tapping [Open reader].
  • Page 25 "No_CT present" status "Lock" Fig. 26: Fig. 27: password prompt ► Enter the password "BISLLOCKER". ⇒ After the password is entered successfully, a new ID can be assigned to the data carrier. Fig. 28: Assigning an ID to data carriers www.balluff.com...
  • Page 26 BIS C-87_ Handheld Programmer Operation 5.7 Working with files Note Data read from a data carrier can be saved under a file name. Already saved data can be opened and further processed. ► Saving files Switch to the "File Browser" tab. ►...
  • Page 27 A rechargeable battery with high capacity has a battery life of up to 48 hours after a full charge. Prerequisite: 200 read/write operations, after 3 min. without being used, the device enters Suspend Mode. Data in the Handheld Programmer are retained for at least 10 to 15 minutes while the battery is being replaced. www.balluff.com...
  • Page 28 BIS C-87_ Handheld Programmer Technical data Dimensions Fig. 31: BIS C-870-1-008-X-000 dimensions (in mm) Fig. 32: BIS C-871-1-008-X-000 dimensions (in mm) Fig. 33: BIS C-873-1-008-X-000 dimensions (in mm)
  • Page 29 Charging time Charge life Prerequisite, see page 7 48 h Operating Ambient temperature -10 °C to +50 °C conditions – EN 61000-4-2/3/4/5/6 – Severity level 3A/3A/–/–/– – EN 55011 – Gr. 1, Cl. A Vibration/shock EN 60068 Part 2-6/27/29/64/32 www.balluff.com...
  • Page 30 BIS C-15_-XX 873 = Portable reader with integrated read/write head for data carriers with Ø < 20 mm Interface 1 = Bluetooth Software type 008 = Balluff software for BIS _-87x-... Langage X = Multilingual Additional features 000 = Standard...
  • Page 31 100-240 V primary Secondary voltage U ± 5 % Input frequency F 50-60 Hz primary Secondary current I 2.1 A Ambient temperature T −40 °C to +70 °C Material PPE-V1-125 °C Color Black Material number 11023834 Color Black Interface www.balluff.com...
  • Page 32 BIS C-87_ Handheld Programmer Appendix ASCII table Decimal Control ASCII Decimal ASCII Decimal ASCII Code Ctrl @ Ctrl A Ctrl B Ctrl C Ctrl D Ctrl E Ctrl F Ctrl G Ctrl H Ctrl I Ctrl J Ctrl K Ctrl L Ctrl M Ctrl N Ctrl O...
  • Page 33 CRC check 18 Handheld Programmer Intended 6 Product description 16 Improper 6 Conventions 4 Main components 16 Files 17 File format 17 Accessories 28 Charger 29 Data Data integrity 17 Editing 22 Parameters Read operation 13, 20 CRC_16 data check 11 www.balluff.com...
  • Page 34 Balluff GmbH Schurwaldstraße 9 73765 Neuhausen a.d.F. Germany Phone +49 7158 173-0 Fax +49 7158 5010 balluff@balluff.de www.balluff.com...