Contents
Technical Overview ...................................................................................................................................... 2
I. Important Notes ..................................................................................................................................... 2
II. Specifications ........................................................................................................................................ 2
III. WARNING............................................................................................................................................ 2
IV. Before you Purchase/Open .................................................................................................................. 2
V. Space Requirements ............................................................................................................................ 3
VI. What is Ultraviolet Sanitation ............................................................................................................... 3
VII. Example Applications ......................................................................................................................... 3
Installation Introduction ................................................................................................................................. 3
I. Site Preparation ..................................................................................................................................... 3
II. Mounting ............................................................................................................................................... 4
III. Installing Connections .......................................................................................................................... 4
IV. Filter Protection ................................................................................................................................... 4
Commissioning & Start-up ............................................................................................................................ 4
I. Quartz Thimble Installation ..................................................................................................................... 4
II. Installing the UV Lamp .......................................................................................................................... 4
Maintenance ................................................................................................................................................. 5
I. Replacement Parts................................................................................................................................. 5
Troubleshooting ............................................................................................................................................ 6
GT7-2K GT7-4K GT7-8K
Ultraviolet System Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GT7-2K and is the answer not in the manual?

Questions and answers

Summary of Contents for FSA GT7-2K

  • Page 1: Table Of Contents

    GT7-2K GT7-4K GT7-8K Ultraviolet System Manual Contents Technical Overview ............................2 I. Important Notes ............................. 2 II. Specifications ............................2 III. WARNING............................2 IV. Before you Purchase/Open ........................2 V. Space Requirements ..........................3 VI. What is Ultraviolet Sanitation ....................... 3 VII.
  • Page 2: Technical Overview

    Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. II. Specifications Part Number GT7-2K GT7-4K GT7-8K Flow Rate @ 30mJ/cm² 3.8L/Min...
  • Page 3: Space Requirements

    Humidity & Frost. For external installations, the ballast must be installed in an IP 65 or better waterproof enclosure (not supplied). The System is supplied with either plastic (GT7-2K) or Aluminium mounting clamps designed for installation on the wall (screws not included). It is ideal for the system to be mounted horizontally however if necessary, vertical installation (open end to the top) is acceptable, the outlet should also be at the top.
  • Page 4: Mounting

    III. Installing Connections The UV systems are manufactured with male BSP threads either in 1” (GT7-8K) or ½” (GT7-4K). The smaller GT7-2K unit is ¼” Female. Use appropriate plumbing fittings to install onto the chamber for adapting to your plumbing.
  • Page 5: Maintenance

    40W Replacement UV Lamp Suit GT7-8K Quartz Thimble Replacement | Every 1 – 2 years depending on water quality GT7-2K-Thimble 331mm x 23mm OD Single Open-End Thimble Suit GT7-2K GT7-4K-Thimble 490mm x 23mm OD Single Open-End Thimble Suit GT7-4K GT7-8K-Thimble...
  • Page 6: Troubleshooting

    High Water 1. Low Flow Rate 1. Particularly on the smaller model (GT7-2K) if Temperature there are periods of low water usage or the water is allowed to stand for long periods of time, the water may be prone to heating up and may be either lukewarm or hot.
  • Page 7 for; Water ingress from either rain, or leaks or any signs of moisture or condensation in/around the electricals. Due to the elevated temperature of the lamp, high humidity may cause condensate to form. If there are no signs of leaking, check for signs of shorts or charring on the lamp connection with the ballast.
  • Page 8 FSA will not cover any labour charge incurred by the consumer for the replacement or repair of a product. The warranty is strictly parts only for the parts supplied by FSA. This warranty only applies to the original consumer of the product and is non-transferable.
  • Page 9 ² Other products not manufactured or assembled by FSA are covered under the applicable manufacturer’s warranty. ³ FSA specifies recommended or required filter maintenance – see product information for further details. If a maintenance schedule is not specified, filter maintenance is required at least once per 12 month period.