INSTRUCTIONS FOR USE
C5 E-SERIES
HEATED HOLDING & PROOFING CABINETS

TABLE OF CONTENTS

Safety Information & Symbols ...................................... 2
Identifying your Cabinet................................................ 2
Installation and Setup ................................................... 3
Operating Instructions .................................................. 4
Care and Maintenance ................................................. 4
Basic Troubleshooting .................................................. 5
Reversing the Door ....................................................... 6
Service and Replacement Parts ................................... 7
Service and Replacement Parts (Circuits) ................... 9
Warranty ......................................................................10
Metro Heated Cabinets are for
Hot Food Holding applications only.
DESCRIPTION
This manual covers cabinets with electrical ratings of: 120V, 60 Hz, 2000W and
© 2018 InterMetro Industries Corporation, Wilkes-Barre, PA 18705
L01-633
01/2019
220-240V, 50/60 Hz, 1681-2000W

Advertisement

loading
Need help?

Need help?

Do you have a question about the C5 E-Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Metro DataVac C5 E-Series

  • Page 1: Table Of Contents

    INSTRUCTIONS FOR USE C5 E-SERIES HEATED HOLDING & PROOFING CABINETS TABLE OF CONTENTS Safety Information & Symbols ........2 Identifying your Cabinet..........2 Installation and Setup ........... 3 Operating Instructions ..........4 Care and Maintenance ..........4 Basic Troubleshooting ..........5 Reversing the Door ............
  • Page 2: Safety Information & Symbols

    C5 E-Series Heated Holding & Proofing Cabinets SAFETY INFORMATION WARNING: Follow all food safety guidelines. Pre-heat the cabinet to the desired temperature before placing cooked, hot food into the cabinet. This is not a re-thermalizing cabinet. Food must be at the appropriate temperature before being placed into this cabinet.
  • Page 3: Installation And Setup

    C5 E-Series Heated Holding & Proofing Cabinets INSTALLATION AND SETUP 1. Check the packaging and cabinet for shipping damage after unloading the unit, and after removing all the packaging. 2. The receiver of this product is responsible for filing freight damage claims. This equipment must be opened immediately for inspection.
  • Page 4: Operating Instructions

    C5 E-Series Heated Holding & Proofing Cabinets OPERATING INSTRUCTIONS Thermostat Power / Selector Switch Thermometer 1. Fill the stainless pan with water if proofing, or if you desire a small amount of passive humidity while in heated holding mode. 2. Your cabinet has a 3 way power / selector switch that powers the cabinet on and off and also allows dual functionality.
  • Page 5: Basic Troubleshooting

    C5 E-Series Heated Holding & Proofing Cabinets Cabinet Maintenance — All Models Keeping the casters free of dirt build-up will go a long way in prolonging their life. Additionally, periodic tightening of door latch and hinge screws may be required.
  • Page 6: Reversing The Door

    C5 E-Series Heated Holding & Proofing Cabinets REVERSING THE DOOR The door on your cabinet can be reversed to accommodate a right- or left-hand opening. The cabinet has been shipped with the hinges mounted on the right-hand side. To reverse, follow the instructions listed below: 1.
  • Page 7 C5 E-Series Heated Holding & Proofing Cabinets C5 E-SERIES CABINET REPLACEMENT PARTS DIAGRAM Heat Module (top side) Heat Module (under side) L01-633...
  • Page 8: Service And Replacement Parts

    C5 E-Series Hot Food Holding Cabinets C5 E-SERIES SERVICE AND REPLACEMENT PARTS* WARNING: Only factory approved service agents must attempt to service, repair or replace electrical components, wiring or power cord. Module CABINET BODY Item# Replacement Part No. Description Item# Replacement Part No.
  • Page 9 C5 E-Series Heated Holding & Proofing Cabinets WIRING DIAGRAM 120V AND 220 / 240V GROUND WIRE MOTOR 1950WATT HEATING ELEMENT T.O.D 650WATT HEATING ELEMENT GROUND WIRE BLACK WIRE WHITE WIRE 3 WAY SWITCH TERMINAL BLOCK THERMO STAT L01-633...
  • Page 10 C5 E-Series Heated Holding & Proofing Cabinets ® 01/2019 For online warranty registration, please go to www.metro.com/service-support/thermal-cabinets to register electronically L01-633...
  • Page 11 C5 E-Series Heated Holding & Proofing Cabinets THIS PAGE IS KEPT INTENTIONALLY BLANK L01-633...
  • Page 12 C5 E-Series Heated Holding & Proofing Cabinets US/Can: 1.800.992.1776 Corporate Headquarters (US): 1.570.825.2741 For Inquiries Outside of the U.S. and Canada, Visit www.metro.com/contactus L01-633 01/2019 www.metro.com L01-633...