260 L DC CFC FREE
DIAGNOSING THE ELECTRICAL COMPONENTS
COMPONENTS
* Use the Multimeter to measure the
winding Resistance
?
- Bring the Compressor to cool down
Compressor
Compressor
completely before measuring
?
* Switch on the Compressor
* Switch On the Compressor
* Use the Multimeter to check the
continuity
Relay
* Use the Multimeter to check the
Over Load
continuity
Protector
* Use the Multimeter to check the
continuity
Thermostat
* Take out the capillary from Freezer
* Use the Multimeter to check the
continuity
Door Switch
Signalization
Physical Check
Module
This document is only intended for qualified technicians who are aware of the respective safety regulations.
First Released Date 17
Document No. WOI/DC/2002/07
DIAGNOSING METHODS AND CRITERIA
* All components & wires are properly "Earthed"
* Green LED is "ON" when Compressor is "ON" & it's "OFF" when
Compressor is "OFF"
* Red LED is "ON" when Power is "ON" & it's "OFF" when
Power is "OFF"
* Both LEDs are straight & not bend
* Any component on PCB is burnt
* Black wire is connected to Common, Red wire is connected to Power &
Blue wire is connected to Compressor, as written on PCB
TH
July, 2002
Subject to modification
PAGE 20 of 21
Whirlpool of India
Measuring
point
Normal
Main winding to
common
14-16
Starting winding to
common
44-50
Red wire
connected to OLP
1 to 1.3 Amp
Normal
Relay in Mounting
Continuity between
position
Input terminal & RHS Pin No continuity
Relay in reverse
Continuity between
position
Input terminal & LHS Pin No continuity
Normal
Continuity between
Supply terminal &
terminal to Compressor
Position Measuring point
Normal
Between two
supply terminals
Continuity
ON
Between two
supply terminals
No Continuity
OFF
Position Measuring point
Normal
Lever
Between two
Open
supply terminals
Continuity
Lever
Between two
pressed
supply terminals
No Continuity
Abnormal
?
0
?
&
> 1.3 Amp
Abnormal
Abnormal
No continuity
Abnormal
No Continuity
Continuity
Abnormal
No Continuity
Continuity

Advertisement