260 L DC CFC FREE
TROUBLE CHECK FOR THE COOLING CYCLE
SYMPTON
?
The Evap. Cools down & warms again
?
The condenser warms in proportion as
the Evaporator cools
?
The process continues to repeat
?
The condenser is cold
?
The evaporator is not cold
?
Compressor Temp. is high
?
Compessor current is higher than rated
?
No difference in temperature between
suction pipe and discharge pipe
?
The temperature of compressor is
maintained at room temperature
?
The Evap. Does not cool down
?
Frost on the suction pipe
?
The condenser is overheated
?
The refrigerant in the evaporator is not
efficient
?
Compressor current is higher than
rated
?
The compressor surface temperature is
high
?
The condenser is cold
?
The refrigerator is not easily getting
cooled
?
Compressor current is lower than rated
This document is only intended for qualified technicians who are aware of the respective safety regulations.
First Released Date 17
Document No. WOI/DC/2002/07
Moisture in the refrigerant
causes the malfunction
Foreign substances hamper
The compressor is defective
TH
July, 2002
Subject to modification
PAGE 18 of 21
CAUSE
cooling
Too much refrigerant
Refrigerant leak (slight
refrigerant leakage causes
partial cooling with frost on
Evap.)/Less charge
Whirlpool of India
SUGGESTIONS
Flush/vacuum the system and
recharge the refrigerant and replace
the drier
Flush the system and recharge
and replace the drier
Replace the compressor,
recharge the refrigerant and
replace the drier
Recharge the refrigerant and
replace drier
After repairing the leaked
spot (if any), recharge the
refrigerant and replace drier