Checkout Procedure - Weil-McLain EG 6 Series Manual

Gas-fired boilers, control supplement - universal control systems
Table of Contents

Advertisement

Universal Control Systems

Checkout procedure

1. See pages 22–26 for "Operating instructions."
2. Raise room thermostat to call for heat. Damper actuator will slowly open damper.
3. When damper is fully open, main gas valve will open and main burners will ignite.
Damper must be fully open before main burners light. If damper does not fully open, flue products will escape into
house, causing severe personal injury or death.
4. Lower thermostat setting. Main burner flames will go out, then damper will close.
5. Repeat steps 1 through 3 several times to verify operation.
6. Return thermostat to normal setting.
Room thermostat anticipator settings
Water without tankless heater — 0.40 amps
Water with tankless heater — 0.20 amps
Steam — Select based on gas valve and damper. See table below.
Boilers with
United Technologies
Ignition control
(Control load of 0.10 amps is
included in the values at right)
Boilers with
Honeywell
Ignition control
(Control load of 0.20 amps is
included in the values at right)
Part Number 550-142-304/1220
Gas valve
Honeywell VR8200
Honeywell VR8300
Robertshaw 7200ER
Robertshaw 7000ERHC
White-Rodgers 36E
White-Rodgers 36C
Gas valve
Honeywell VR8200
Honeywell VR8300
Robertshaw 7200ER
Robertshaw 7000ERHC
White-Rodgers 36E
White-Rodgers 36C
With
Without
damper
damper
(amps)
(amps)
0.60
0.70
0.80
0.90
0.50
0.60
0.80
0.90
0.40
0.50
0.70
0.80
Without
Without
damper
damper
(amps)
(amps)
0.70
0.80
0.90
1.00
0.60
0.70
0.90
1.00
0.50
0.60
0.80
0.90