CorroVenta VENTOVIND PRO User Manual

Demand controlled ventilation for attics

Advertisement

Quick Links

VENTOVIND™ PRO
Demand controlled ventilation
for attics
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VENTOVIND PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CorroVenta VENTOVIND PRO

  • Page 1 VENTOVIND™ PRO Demand controlled ventilation for attics USER MANUAL...
  • Page 2: Table Of Contents

    Sensor unit VentoVind PRO ..........................17 ™ VentoVind PRO Villa fan, KVK Silent 160 ......................17 ™ VentoVind PRO Villa Large fan, KVK Silent 200 ....................18 Accessories and Spare parts ..........................18 © Corroventa Avfuktning AB 2021.05 1 (18)
  • Page 3: Area Of Use

    Properties: • Energy efficient • Very quiet • Flexible • Service-friendly • Robust © Corroventa Avfuktning AB 2021.05 2 (18)
  • Page 4: Manufacture Directive

    These user instructions contain information protected by copyright laws. No part of this document may be reproduced, stored in an information storage system or transmitted in any way or by any means without Corroventa AB's written consent. Any comments regarding the content of this document must be sent to: Corroventa Avfuktning AB Tel.: +46 (0)36-37 12 00.
  • Page 5: Safety Information

    Humidity: 20 – 100 % relative humidity, non-condensing. Max. height above sea level: 0 to 2000m 19. VentoVind™ must not be used with accessories other than those described in this manual or approved by Corroventa Avfuktning AB. 20. Installation work in attic spaces can involve: Uncomfortable working positions, dusty air, mould spores, poor lighting etc.
  • Page 6: Relative Humidity And Its Impact On Materials

    An adult human being evaporates approximately 40 - 50 grams of water per hour when at rest at room temperature and a family can easily produce 10 litres of water per day that evaporates into the © Corroventa Avfuktning AB 2021.05...
  • Page 7 There is otherwise a great risk, among other things, of increased transport of moist air up to the attic. © Corroventa Avfuktning AB 2021.05...
  • Page 8: How Ventovind™ Works

    The VentoVind™ system is pre-set so that the dehumidifier is put into operation as required, i.e. only when drying with adaptive ventilation is not able to lower the humidity below the set level. Only dehumidifiers intended for fixed installations in cold attics are recommended for this type of installation. © Corroventa Avfuktning AB 2021.05 7 (18)
  • Page 9: Delivery Check

    Control panel. Voltage +5 VDC 800mA (Only use the AC adapter supplied) Indoor sensor. Voltage +24 VDC via ModBus Outdoor sensor. Voltage +24 VDC via ModBus Fan. Voltage 230 VAC 50Hz Max output 315W © Corroventa Avfuktning AB 2021.05 8 (18)
  • Page 10: Ventovind ™ Installation

    In simpler © Corroventa Avfuktning AB 2021.05...
  • Page 11: Electrical Socket

    3. Attach age-resistant construction plastic over the inlet or outlet for ceiling ventilation. 4. Seal the vapour barrier downwards to the living area with PE tape, polyurethane foam and age-resistant construction plastic. © Corroventa Avfuktning AB 2021.05 10 (18)
  • Page 12: Vapour Barrier At Joist Level

    The function of the damper is to allow air to exit the attic in the event of overpressure. Ensure that the damper opens when touched lightly, and springs back and closes without problem. Finally, install the guard. The intended air flow is indicated by arrows. © Corroventa Avfuktning AB 2021.05 11 (18)
  • Page 13: Fan Installation

    Install the supplied brackets on the control unit. Tap in the pins to secure the mountings to the control box. Then mount the control unit on a flat surface centrally and make sure it is easy to access. © Corroventa Avfuktning AB 2021.05...
  • Page 14: Installing Sensors

    • When removing the sensor cable ensure that the current to the control unit is disconnected. © Corroventa Avfuktning AB 2021.05 13 (18)
  • Page 15: Starting And Settings

    80 - 100%. If the damper does not open, the leak in the attic space is too large and additional sealing is required for proper function. Check that the damper flaps open without any problems when touched lightly and spring back to the closed position. © Corroventa Avfuktning AB 2021.05 14 (18)
  • Page 16: Maintenance And Service

    The damper flaps should move freely and spring back after being touched. It can be advantageous to perform the same test as at installation, where you test operate the fan manually. See more under chapter Starting and Settings. © Corroventa Avfuktning AB 2021.05 15 (18)
  • Page 17: Servicing The Control Unit And Sensors

    Dirt/dust on the fan wheel -Clean the fan according to the service causes imbalance and instructions. vibration noise. If the measures described above did not remedy the error, contact your dealer for necessary service and support. © Corroventa Avfuktning AB 2021.05 16 (18)
  • Page 18: Technical Data

    Max. temperature of transported air during voltage control, °C Sound pressure level, 3m, db.(A) Weight, kg 17.2 Insulation class, motor Enclosure class, motor IP44 Capacitor, off Duct connection: circular, intake / Exhaust. mm © Corroventa Avfuktning AB 2021.05 17 (18)
  • Page 19: Ventovind ™ Pro Villa Large Fan, Kvk Silent 200

    Control unit VentoVind complete 10326 Panel HomeVision Pro 6000211 AC adapter white 6000221 Guard Ø 200mm 6000222 Wall plate 200mm 6000192 Hose 1.5m Ø 200mm 6000223 Back draft damper 200mm 1001112 Suspension wire VentoVind © Corroventa Avfuktning AB 2021.05 18 (18)
  • Page 20 In emergency situations and during flooding, CORROVENTA LTD Corroventa’s customers have access to one of the largest rental parks in Europe. Unit 47, Melford Court, Hardwick Grange, Warrington All our products are manufactured in Bankeryd, Sweden.

Table of Contents