CorroVenta HP 2000XT User Manual

Radial fan

Advertisement

Quick Links

RADIAL FAN
HP 2000XT
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HP 2000XT and is the answer not in the manual?

Questions and answers

Summary of Contents for CorroVenta HP 2000XT

  • Page 1 RADIAL FAN HP 2000XT USER MANUAL...
  • Page 2: Table Of Contents

    Table of Contents User Manual HP 2000XT .......................... 3 Intended use ............................3 Manufacturing Directive ........................3 Safety information ..........................4 Delivery inspection ..........................5 Product Overview ..........................5 Drying method – Pressure drying ......................6 Accessories ............................7 Installation ............................7 Fault finding ............................
  • Page 3: User Manual Hp 2000Xt

    The inlet to the fan faces the floor and on its back it has one 100mm outlet and six 50 mm outlets to allow for the air to be distributed through hoses as required. The HP 2000XT is robust and has rubber feet to prevent scratching or discoloring the floors. It is equipped with an electromechanical hour counter alt. Time/Kwh meter.
  • Page 4: Safety Information

    Children must not be allowed to play with the equipment. Cleaning and maintenance must not be performed by children without supervision. Electrical installations made in connection with the installation of the HP 2000XT shall be made by authorized personnel in accordance with local and national regulations.
  • Page 5: Delivery Inspection

    HP 2000XT is delivered with the following items included: Radial fan HP 2000XT 1 pc Manual 1 pc Product Overview Below pictures present HP 2000XT with all its external features and controls. Foldable carrying Power switch, on/off Fan speed selector handle (Red switch) Hour meter alt.
  • Page 6: Drying Method - Pressure Drying

    Pressure drying The dry air from the dehumidifier is led through hose to the HP 2000XT so that it is close to the fan inlet. To the outlets, hoses are connected to feed the dry air into the construction. This way, a pressure drying effect is achieved, pushing the dry and warm air into the construction.
  • Page 7: Accessories

    99.95% for up to 1080m3 / h. The unit also includes a carbon filter layer for removing bad odours. Installation 1. Put the HP 2000XT where it shall be used and connect the hoses, if any, that are to be used for the air distribution.
  • Page 8: Technical Data

    Technical data HP 2000XT Typ LAF 50 LAF 50E LAF 50E2 LAF 100 LAF 100E LAF 150 LAF 150E High speed: 1500 Air volume (m Low speed: 500 Voltage 230 VAC / 50 Hz Rated power (W) Height x width x length (mm)
  • Page 9 DO YOU HAVE ANY QUESTIONS OR DO YOU NEED OUR SUPPORT? Please visit www.corroventa.com or call us at +44 (0)161-244 95 23 and speak to an expert. We have the knowledge and the equipment to find a solution as efficiently as possible.

Table of Contents