The test report only allows to be revised within three years from its original issued date unless further standard or the requirement was noticed.
−
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability
are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for
any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its
entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by
Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or
service is or has ever been under an Intertek certification program.
Page 1
RadioShack Corporation Application Certification (FCC ID: AAO120495) Transmitter HK08061007-1 TC/el July 28, 2008 − The test report only allows to be revised within three years from its original issued date unless further standard or the requirement was noticed. − This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement.
Page 2
INTERTEK TESTING SERVICES LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual EXHIBIT 8: Miscellaneous Information EXHIBIT 9: Confidentiality Request FCC ID: AAO120495...
Page 3
INTERTEK TESTING SERVICES MEASUREMENT / TECHNICAL REPORT RadioShack Corporation − MODEL: Gigaware 12-495 FCC ID: AAO120495 July 28, 2008 This report concerns (check one:) Original Grant Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? If yes, defer until: date Company Name agrees to notify the Commission by:...
INTERTEK TESTING SERVICES General Description Product Description This EUT is a FM Transmitter with scanning function connects to iPod Player. The main function is used to transmit the music stored in yours iPod Player that can be receiving it by yours radio. It is powered by a cigarette adaptor. The blue backlight will be lighted while plug into the cigarette lighter jack of your car.
INTERTEK TESTING SERVICES Test Methodology Radiated emission measurements were performed according to the procedures in ANSI C63.4 (2003). Radiated Emission measurement was performed in Open Area Test Sites. Preliminary scans were performed in the Open Area Test Sites only to determine worst case modes. All Radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the "Justification Section"...
INTERTEK TESTING SERVICES System Test Configuration Justification The system was configured for testing in a typical fashion (as a customer would normally use it), and in the confines as outlined in ANSI C63.4 (2003). The EUT was powered by its cigarette adaptor (Input: 12VDC). For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied from 1 meter to 4 meters above the ground plane, and the antenna polarization was changed.
INTERTEK TESTING SERVICES Equipment Modification Any modifications installed previous to testing by RadioShack Corporation will be incorporated in each production model sold / leased in the United States. No modifications were installed by Intertek Testing Services Hong Kong Ltd. Measurement Uncertainty When determining the test conclusion, the Measurement Uncertainty of test has been considered.
Page 13
INTERTEK TESTING SERVICES Emission Results Data is included worst case configuration (the configuration which resulted in the highest emission levels). A sample calculation, configuration photographs and data tables of the emissions are included. FCC ID: AAO120495...
INTERTEK TESTING SERVICES Field Strength Calculation The field strength is calculated by adding the reading on the Spectrum Analyzer to the factors associated with preamplifiers (if any), antennas, cables, pulse desensitization and average factors (when specified limit is in average and measurements are made with peak detectors). A sample calculation is included below.
Page 15
INTERTEK TESTING SERVICES Field Strength Calculation (cont’d) Example Assume a receiver reading of 62.0dBµV is obtained. The antenna factor of 7.4dB and cable factor of 1.6dB is added. The amplifier gain of 29dB is subtracted. The pulse desensitization factor of the spectrum analyzer was 0dB, and the resultant average factor was −10dB.
INTERTEK TESTING SERVICES Radiated Emission Data The data on the following page lists the significant emission frequencies, the limit and the margin of compliance. Numbers with a minus sign are below the limit. Judgement: Passed by 4.0dB margin TEST PERSONNEL: Signature Terry C.
Page 18
INTERTEK TESTING SERVICES Company: RadioShack Corporation Date of Test: June 19, 2008 Model: Gigaware 12-495 Worst Case Operating Mode: Transmitting Table 1 Radiated Emissions Pre- Antenna Reading Net at 3m Limit at 3m Frequency factor Margin Polarization (MHz) (dBµV) (dB) (dB) (dBµV/m) (dBµV/m)
Page 19
INTERTEK TESTING SERVICES Company: RadioShack Corporation Date of Test: June 19, 2008 Model: Gigaware 12-495 Worst Case Operating Mode: Transmitting Table 2 Radiated Emissions Pre- Antenna Reading Net at 3m Limit at 3m Frequency factor Margin Polarization (MHz) (dBµV) (dB) (dB) (dBµV/m) (dBµV/m)
Page 20
INTERTEK TESTING SERVICES Company: RadioShack Corporation Date of Test: June 19, 2008 Model: Gigaware 12-495 Worst Case Operating Mode: Transmitting Table 3 Radiated Emissions Pre- Antenna Reading Net at 3m Limit at 3m Frequency factor Margin Polarization (MHz) (dBµV) (dB) (dB) (dBµV/m) (dBµV/m)
Page 22
INTERTEK TESTING SERVICES Equipment Photographs For electronic filing, photographs of the tested EUT are saved with filename: external photos.pdf and internal photos.pdf. FCC ID: AAO120495...
Page 24
INTERTEK TESTING SERVICES Product Labelling For electronics filing, the FCC ID label artwork and the label location are saved with filename: label.pdf. FCC ID: AAO120495...
Page 26
INTERTEK TESTING SERVICES Technical Specifications For electronic filing, the block diagram and schematic of the tested EUT are saved with filename: block.pdf and circuit.pdf respectively. FCC ID: AAO120495...
Page 28
INTERTEK TESTING SERVICES Instruction Manual For electronic filing, a preliminary copy of the Instruction Manual is saved with filename: manual.pdf. This manual will be provided to the end-user with each unit sold / leased in the United States. FCC ID: AAO120495...
INTERTEK TESTING SERVICES EXHIBIT 8 MISCELLANEOUS INFORMATION FCC ID: AAO120495...
Page 30
INTERTEK TESTING SERVICES Miscellaneous Information The miscellaneous information includes details of the measured bandwidth and the test procedure. FCC ID: AAO120495...
INTERTEK TESTING SERVICES Measured Bandwidth For electronic filing, the plot on saved in bw.pdf shows the fundamental emission which is applied iPod Video as audio input source in maximum volume. From the plot, it shows the emission is within 200kHz band. FCC ID: AAO120495...
INTERTEK TESTING SERVICES Discussion of Pulse Desensitization Pulse desensitivity is not applicable for this device. Since the transmitter transmits the RF signal continuously. FCC ID: AAO120495...
INTERTEK TESTING SERVICES Calculation of Average Factor The average factor is not applicable for this device as the transmitted signal is a continuously signal. FCC ID: AAO120495...
INTERTEK TESTING SERVICES Emissions Test Procedures The following is a description of the test procedure used by Intertek Testing Services Hong Kong Ltd. in the measurements of transmitters operating under Part 15, Subpart C rules. The test set-up and procedures described below are designed to meet the requirements of ANSI C63.4 −...
Page 35
INTERTEK TESTING SERVICES Emissions Test Procedures (cont’d) The EUT is warmed up for 15 minutes prior to the test. AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental emission field strength is recorded. If battery powered, a new, fully charged battery is used.