Step
3. Remove the main PCB.
Remove the screw on
1
the terminal board.
Cut the clamp.
2
Remove the 2 screws
3
of the earth wire.
Disconnect the 2
4
terminals of the reactor.
Removal Procedure
Procedure
Reactor
Brown
White
Removal of Electrical Box / PCBs
Terminal board
Main PCB
(R15865)
(R15866)
(R15867)
(R15868)