Download Print this page

Pyramid APEX 5000 Series Installation & Operation Manual page 9

Bill acceptor

Advertisement

Front Bezel Lighting Flash Codes
The flash codes shown correspond to the Apex bill acceptor error. The acceptor will flash the
error code, then wait 3 seconds and flash it again.
Flashing Code
LED's always OFF
LED's always ON
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
10 Flashes
Rapid Flashing
During Operation
Meaning of Flashing Code
The acceptor has no power.
No error exists- acceptor is OK.
Something is in the bill path.
Something is obstructing the
stacker.
The cassette is full of currency.
The cassette has been removed.
The acceptor is defective.
The acceptor is not enabled.
Configuration Mode has been
entered.
The acceptor has detected a
stringing attempt, or the optical
anti-stringing sensor is dirty.
Corrective Action
Check that power has been
applied.
None.
Remove the cassette and Lower
Transport to inspect for foreign
objects. Clean if necessary.
Remove the cassette and Lower
Transport to inspect for foreign
objects. Clean if necessary.
Remove the cassette and empty it.
Replace the cassette.
Replace the acceptor.
Verify that the host has enabled
the acceptor.
Configuration Card must be
inserted into the acceptor or cycle
power to the acceptor to exit this
mode. See Configuration Section
for details.
Remove the Lower Transport and
clean the optical anti-stringing
sensor pair openings. These
sensor openings are located on
the Lower Transport, about ½ "
behind the round, white plastic
rollers, and to the far left and right
of the bill path. It is a good idea to
clean all of the sensors at this
time, both the entire upper and
lower halves of the bill path.
Reinstall the Lower Transport and
cycle the power.