Download Print this page

Pyramid APEX 5000 Series Installation & Operation Manual page 14

Bill acceptor

Advertisement

12 VDC Model- Connect +12 VDC to Pin 11 (Red wire) on the 18-pin connector (see Figure 1).
Connect DC Ground to Pin 4 (Black wire) on the 18-pin connector.
In addition, both the 120 VAC model and 12 VDC model have an "Out of Service" output located on Pin 10
(Tan wire) of the 18-pin connector. It is a normally high, open-collector output transistor that is pulled low
when the acceptor is Out of Service. (5-12 VDC at 40 ma Max.) Pin 13 (White/Orange wire) of the 18-pin
connector has a 330 ohm resistor tied to +5VDC to power an LED.
Outputs
120 VAC or 24 VAC Model- You can use the relay output on Pin 7 (Brown) and Pin 8 (Blue) of the 9-pin
connector, or you can use the normally high, open-collector output transistor on Pin 1 (Brown wire) on the
18-pin connector. (5-12 VDC at 40 mA Max.)
12 VDC Model- Use the normally high, open-collector output transistor on Pin 1 (Brown wire) on the 18-pin
connector (5-12 VDC at 40 mA max.)
All outputs will send the number of pulses and pulse speed as set by the Configuration Card.
RS-232 Mode (True RS-232 and TTL RS-232)
Note: To enable this mode on the acceptor, make sure the Configuration Card has been configured for "RS-
232" mode. In this mode, the user has a choice of True RS-232 levels or TTL levels.
TTL (5 VDC) levels are available in the 120 VAC model, 24 VAC and 12 VDC model of the Apex bill
acceptor. Order our Acceptor I/O Harness, Generic (P/N 05AA0002). With this cable, you must manually
connect the wires to your machine.
True RS-232 levels are available only in the 12 VDC Model of the Apex bill acceptor. In the 12 VDC
version, the harness has a DB-9 connector and hard drive connector installed to ease customer installation.
Order RS-232 Communication Harness (P/N 05AA0009) to have this ability if you use RS-232. If you use
USB, order USB Communication Harness( P/N 05AA0023).
This RS-232 mode uses a three wire interface. This interface uses a Transmit Line (TXD), a Receive Line
(RXD) and DC ground (Gnd).
This RS-232 Interface is compatible with the interface used on Mars™ GL5™ style acceptors. It is a polled
interface where the host machine is the Master and the bill acceptor is the Slave
communication protocol details, see the "support" section of our website.
TTL RS-232 Mode Power and I/O Connections (Refer to Figure 1 for Pinouts)
Pin Function & Location
DC Ground- Pin 4 (Black
wire) on the 18-pin connector.
+12VDC- Pin 11 (Red wire)
on the 18-pin connector.
120 VAC Hot- Pin 4 (Black
wire) on the 9-pin connector.
24 VAC Hot- Pin 5 (Black
wire) on the 9-pin connector.
120 VAC or 24 VAC Neutral-
Pin 6 (White wire) on the 9-
pin connector.
TXD Line- Pin 5 (Green wire)
on the 18-pin connector.
RXD Line- Pin 16 (White/Red
wire) on the 18-pin connector.
True RS-232 Mode Power and I/O Connections
Pin Function and Location
DC Ground- Pin 2 (Black wire) on the
Hard Drive connector.
Apex 12 VDC Version
DC communication ground and
DC power ground.
12VDC acceptor power.
Do not use this pin for 12 VDC
version.
Do not use this pin for 12 VDC
version.
Do not use this pin for 12 VDC
version.
TXD- Apex Transmit Line.
Connect to Receive line on your
equipment.
RXD- Apex Receive Line.
Connect to Transmit line on your
equipment.
Apex 12VDC Version
DC power ground.
12
. For RS-232
Apex 120 VAC or 24 VAC Version
DC communication ground.
Do not use this pin for 120 VAC or 24
VAC version!
120 VAC hot.
24 VAC hot.
120 VAC neutral or 24 VAC neutral.
TXD- Apex Transmit Line. Connect
to Receive line on your equipment.
RXD- Apex Receive Line. Connect to
Transmit line on your equipment.

Advertisement

loading

Related Products for Pyramid APEX 5000 Series

This manual is also suitable for:

Apex 7000 series