Download Print this page
Voltex TC1 Installation Manual

Voltex TC1 Installation Manual

1 channel timer

Advertisement

Quick Links

2
DIMENSIONS
18
3
CONNECTION DIAGRAM
16A / 240Vac
4
DISPLAY DESCRIPTION
TC1
6
DEFAULT PARAMETERS
The default parameters show the factory default conditions:
- geographical zone: 1 (Australia)
- summer/winter time: settings
Reset to factory defaults
To reset the timer to factory default settlings,
From the main screen, press all three buttons (
with a pen or similar for at least 3 seconds.
dEF (flashing) will appear on the screen,
When dEF is seen flashing, press the PRG button to confirm the reset
If the PRG is not pressed within 5 seconds, the timer returns to the main
screen without performing a reset.
MODEL: TC1
65
Current time indication
Year, month, day
indication (displayed in
advanced programming)
ON/OFF indication blocks
Relay status
Relay Lock
Programming Menu is Active
Advanced Programming Menu
is Active
Day of the week
relay OFF
relay ON
PRG
) simultaneously
1
Installation Guide
1 Channel Timer
DINrail mounted, electronic timer with weekly and
daily programming
This product should only be installed by a licenced electrician
in accordance with all the requirements of AS/NZS 3000
(current edition) and other relevant Standards and Regulations
Technical Specifications
Power supply
Terminals
Output
Programming
Programming resolution
Operating temperature
Storage temperature
Operating humidity
Width
IP Rating
Relay capacity
Maximum Load
Backup Battery life/type
5
INSTALLATION
The device comes with the backup battery inserted, therefore if
required the timer can be switched on and programmed without a
mains connection. To turn the timer on without a mains connection,
press the PRG button.
Note that when programming without a mains connection, the LED
backlight display and relay will not operate.
Connect the mains supply and the relay output as shown in Section 3.
The backlight display will turn on when the device is mains powered and
remains on while mains is connected.
7
RELAY MANUAL SWITCHING
To change the status of the relay output (from ON to OFF or vice versa)
press the key .
Attention: the status is maintained until the
or until the next program switching.
To lock the current status of the relay and prevent it switching,
press the
button for >3 seconds .
In this condition the
symbol is lit.
To unlock press
button for >3 seconds
240Vac (-15% to +10%) 50/60Hz
1 x 4mm
cable maximum
2
normally open relay
Weekly (a different program for
every day of the week), or
Daily (same program each day)
30 minutes
-20 to +50 °C
-10 to +70 °C
-20 to 90% non-condensing
1 DIN module
IP20
16A @ 240Vac
LED 500 VA
Incandescent 2000 W
Fluorescent 250 VA
Low voltage halogen 1000 VA
Halogen (240 V) 2000 W
CFL 200 VA
4 years/Lithium CR-1632
button is pressed again

Advertisement

loading
Need help?

Need help?

Do you have a question about the TC1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Voltex TC1

  • Page 1 Installation Guide MODEL: TC1 1 Channel Timer DINrail mounted, electronic timer with weekly and daily programming DIMENSIONS This product should only be installed by a licenced electrician in accordance with all the requirements of AS/NZS 3000 (current edition) and other relevant Standards and Regulations Technical Specifications...
  • Page 2 PROGRAMMING ADVANCED PROGRAMMING Programming consists of 7 different Midnight 30-minute From the main screen, press the block OFF programs, one for each day of the for >3 seconds 30-minute This allows you to change: week. block ON - geographical zone of installation The timer splits the 24-hour day up into 48 - date and time, time-blocks, with each block 30 minutes long.