Page 1
HDD-8RB with digital control GALISO CYLINDER DRYER INSTALLATION/OPERATION INSTRUCTION MANUAL MANUAL NUMBER 21-11-1025 Issued November 2016 Rev A Copyright 2016, Galiso, Inc. 22 Ponderosa Ct., Montrose, CO 81401 (970) 249-0233 (800) 854-3789 www.galiso.com...
4.0 Installation ..................4-1 5.0 Operation ..................5-1 6.0 Maintenance ................. 5-2 List of Tables and Figures Number/Title Page Figure 1, HDD Galiso Cylinder Dryer ..........2-1 Figure 2, HDD Controller ..............5-1 ® 2014 Galiso Inc. Rev A...
Page 3
!!!DANGER!!! DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE, VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS ...
1.0 INTRODUCTION The HDD Galiso Heavy Duty Dryer has been designed to quickly dry up to eight drained 9” by 51” cylinders, in relatively short amount of time. The HDD Cylinder Dryer features a PID controlled 8KW heating element and a 1.3 HP Blower Motor that moves hot air through Cylinders at 84 CFM.
Dimensions (frame and blower assembly): 10’2” L x 18” W x 6’6” H Dryer Probes: ½” O.D. x 0.025” wall thickness x 58” std length, with Quick Connect Warranty: One Year (see Galiso Warranty Terms, Form No GSO7805-1). Section 2 - 1...
3.0 SAFETY Read all instructions before attempting to install or operate this machine. GALISO, INCORPORATED IS NOT RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE, APPLICATION, MODIFICATION OR IMPROPER INSTALLATION OF THIS MACHINE. Please contact Galiso, Inc. for guidance when you are in doubt as to the proper safety precautions to be taken when installing or operating this machine.
B. Carefully uncrate the HDD Cylinder Dryer and remove all packing materials. If there are any missing or damaged parts, please call Galiso, Inc. at 1 (800) 854- 3789 and DO NOT attempt to install any pieces until concerns and possible safety issues have been discussed.
5.0 OPERATION A. Check that Cylinders are emptied and drained of water. B. Place a Probe into each Cylinder that is going to be dried, and align under each individual Manifold Outlet. Connect each Probe by pushing up into a Quick Connect on the Upper Body.
NOTE: Cylinder dry times can vary, depending on the size and/or material. Galiso, Inc. recommends using low temperature settings for composite cylinders. ! CAUTION ! The dryer can remain “On”...
Page 13
Galiso. In the event of replacements, the replacement unit will continue under the original equipment warranty or carry a 90-day warranty, whichever is longer. No charge will be made for warranty repairs, and/or replacements.
Page 14
Galiso. In the event of replacements, the replacement unit will continue under the original equipment warranty or carry a 90-day warranty, whichever is longer. No charge will be made for warranty repairs, and/or replacements.