FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT
PART ORDER NUMBER: FA2000EC
OPERATING & MAINTENANCE MANUAL
DOCUMENT NUMBER: OPMM-001E-R0

Advertisement

Table of Contents
loading

Summary of Contents for ACSI FA2000EC

  • Page 1 8720 LAMBRIGHT ROAD HOUSTON, TEXAS 77075 PHONE: (713) 987-0336, FAX: (713) 987-0355 www.acsi-us.com FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT PART ORDER NUMBER: FA2000EC OPERATING & MAINTENANCE MANUAL DOCUMENT NUMBER: OPMM-001E-R0...
  • Page 2: Reference Documents

    REPLACEMENT PARTS LIST NOTE: ALL UNITS MANUFACTURED BY ADVANCED CONTAINMENT SYSTEMS INC. (ACSI) MEET ALL STANDARDS REQUIREMENTS SET BY THE AMERICAN NATIONAL STANDARS INSTITUTE (ANSI) Z2.9, AND ARE OSHA APPROVED. ELECTRICAL COMPONENTS ARE “UL” LISTED AND “CSA” CERTIFIED. 1. GENERAL INFORMATION: The FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT is designed for indoor use and to provide the most efficient air filtration with three stages of filtration.
  • Page 3: Operation

    MECHANICAL COMPONENTS. FAILURE TO COMPLY WILL VOID ALL WARRANTIES. Electrical Requirements: 3.1.1 The FA2000EC requires a minimum of 115 VAC, 60 Hz, 20 amp, power supply for normal operation. 3.1.2 The unit requires a heavy duty industrial grade 12-3 cord, in good condition, and should not exceed 50 ft.
  • Page 4 DOCUMENT NUMBER: OPMM-001E-R0 PS Receptacle High-Off-Low Switch Pressure Gauge Breaker 20 Amp Sensing Port Fig. 1 Control Panel Control Panel: 3.3.1 High-Off-Low Switch to start and select the speed of the unit 3.3.2 Push Button Breaker 20 Amp 3.3.3 Power Supply (PS) Receptacle 15 Amp 3.3.4 Pressure Gauge 3.3.5...
  • Page 5 DOCUMENT NUMBER: OPMM-001E-R0 Fig. 2 Pre-filter Pad Fig. 3 Ring Panel Filter 4. FILTRATION: First Stage Filter (Pre-filter Pad): 24” x 24” x 1” 4.1.1 4.1.2 Double Ply 4.1.3 Removes large particles up to 10 microns and larger from the air flowing through the unit, thereby preventing premature loading of the second stage and HEPA filters.
  • Page 6: Filter Replacements

    UNIT, MUST WEAR APPROVED RESPIRATORS AND PROTECTIVE EQUIPMENT AND TO FOLLOW SAFE WORK PROCEDURE. Pre-filter Pad Replacement: 5.1.1 Turn the FA2000EC unit off and make sure to disconnect the power supply cord from the unit. 5.1.2 Open the door and remove the contaminated pre-filter pad.
  • Page 7 DOCUMENT NUMBER: OPMM-001E-R0 Ring Panel Filter Replacement: 5.2.1 Turn the FA2000EC unit off and make sure to disconnect the power supply cord from the unit. 5.2.2 Open the door and remove the contaminated ring panel filter. 5.2.3 Fold in the sides of the contaminated filter and dispose of as per section 5.4.
  • Page 8: Replacement Parts List

    DOCUMENT NUMBER: OPMM-001E-R0 5.3.10 Close door and fasten the draw latch. 5.3.11 Reconnect the power supply cord, then turn the unit on, and check the pressure gauge at the control panel. If pressure still exceeds the pressure stated above, consult your distributor. Used filter disposal: 5.4.1 Used filters are considered contaminated waste and are to be disposed in...