Table Of Contents; Introduction; Technical Specifications - Daikin EWWP045KAW1M Operation Manual

Hide thumbs Also See for EWWP045KAW1M:
Table of Contents

Advertisement

EWWP045KAW1M ECB1MUW
EWWP055KAW1M ECB2MUW
EWWP065KAW1M ECB3MUW
C
ONTENTS
Introduction ....................................................................................... 1
Description ........................................................................................ 2
Function of the main components.............................................................. 3
Safety devices............................................................................................ 4
Internal wiring - Parts table........................................................................ 4
Before operation................................................................................ 5
Checks before initial start-up ..................................................................... 5
Water supply .............................................................................................. 5
General recommendations ........................................................................ 5
Operation 16~24Hp........................................................................... 5
Digital controller ......................................................................................... 5
Working with the 16~24Hp units ................................................................ 6
Advanced features of the digital controller................................................. 8
Operation 32~72Hp......................................................................... 12
Digital controller ....................................................................................... 12
Working with the 32~72Hp units .............................................................. 12
Advanced features of the digital controller............................................... 14
Troubleshooting ............................................................................... 19
Maintenance.................................................................................... 20
Maintenance activities ............................................................................. 20
Disposal requirements ............................................................................. 20
Technical specifications
General
Hp
Nominal cooling
43.0
(kW)
(a)
capacity
(b)
12.1
Nominal input
(kW)
Dimensions HxWxD
(mm)
Machine weight
300
(kg)
Connections
• water inlet
(inch)
• water outlet
(inch)
Compressor
Type
Qty x model
JT212DA-YE
Speed
(rpm)
Oil type
Oil charge volume
(l)
Evaporator
Type
Qty
Nominal water flow
123
(l/min)
Water flow range
62 -247
(l/min)
Condenser
Type
Qty
Nominal water flow
157
(l/min)
79 - 314 102 - 410 118 - 474 157 - 629 181 -724 205 - 819 221 - 883 237 - 948 260-1038
Water flow range
(l/min)
(a) The nominal cooling capacity is based on:
(b) The nominal input includes total input of the unit: compressor, control circuit and water pumps.
(1) Refer to the engineering data book for the complete list of specifications.
Operation manual
1
(1)
16
20
24
32
56.0
65.0
86
16.0
18.3
24.2
600 x 600 x 1200
320
334
600
2x FBSP 1.5"
2x FBSP 1.5"
2x
2x
2x
4x
JT300DA-YE
JT335DA-YE
JT212DA-YE
2900
FVC 68D
2x 2.7
1
161
186
247
80 - 321 93 - 373 123 - 493 142 - 568 161 - 642 173 -694 186 - 745 204 - 814
1
205
237
314
- entering water temperature of 12°C
- chilled water temperature of 7°C
- condenser in/out water temperature of 30/35°C
Packaged water-cooled water chillers
Page
READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW THIS MANUAL AWAY.
KEEP IT IN YOUR FILES FOR FUTURE REFERENCE.
Read the chapter
changing the parameters.
I
NTRODUCTION
This operation manual concerns packaged water-cooled water
chillers of the Daikin EWWP-KA series. These units are provided for
indoor installation and used for cooling and/or heating applications.
The units can be combined with Daikin fan coil units or air handling
units for air conditioning purposes. They can also be used for
supplying water for process cooling.
This manual has been prepared to ensure adequate operation and
maintenance of the unit. It will tell you how to use the unit properly
and will provide help if problems occur. The unit is equipped with
safety devices, but they will not necessarily prevent all problems
caused by improper operation or inadequate maintenance.
In case of persisting problems contact your local dealer.
Before starting up the unit for the first time, make sure that
it has been properly installed. It is therefore necessary to
carefully read the installation manual supplied with the unit
and the recommendations listed in
start-up" on page
36
40
44
48
99
112
121
130
28.1
32.0
34.3
36.6
1200 x 600 x 1200
620
640
654
668
2x 2x FBSP 1.5"
2x 2x FBSP 1.5"
hermetically sealed scroll
2x
2x
JT212DA-YE
4x
JT300DA-YE
4x
+ 2x
JT300DA-YE
+ 2x
JT335DA-YE
JT300DA-YE
JT335DA-YE
2900
FVC 68D
4x 2.7
brased plate heat exchanger
2
284
321
347
373
brased plate heat exchanger
2
362
410
442
474
Operation manual
"User settings menu" on page 14
"Checks before initial
5.
52
56
60
64
142
155
168
177
40.2
44.1
48.0
50.3
1800 x 600 x 1200
920
940
960
974
3x 2x FBSP 1.5"
3x 2x FBSP 1.5"
4x
2x
4x
JT212DA-YE
JT212DA-YE
6x
JT300DA-YE
+ 2x
+ 4x
JT300DA-YE
+ 2x
JT300DA-YE
JT300DA-YE
JT335DA-YE
2900
FVC 68D
6x 2.7
3
407
444
482
507
222 - 889
241 -963
254-1015
3
519
567
614
647
283-1133
307-1229
323-1293
EWWP045~065KAW1M + ECB1~3MUW
Packaged water-cooled water chillers
before
68
72
186
195
52.6
54.9
988
1002
2x
JT300DA-YE
6x
+ 4x
JT335DA-YE
JT335DA-YE
533
559
267-1066
280-1118
679
711
339-1357
355-1422
4PW30041-1A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewwp055kaw1mEwwp065kaw1mEcb1muwEcb2muwEcb3muw

Table of Contents