Advertisement

Quick Links

LKK Commercial Gas Stockpot
User Manual
P: (+64) 09 837 2960
18 Paramount Drive, Henderson, Auckland
www.lkk.co.nz
F: (+64) 09 836 9168
sales@lkk.co.nz
P: 1300 655 715
F: (+61) 02 8587 0033
47 George St, Clyde Sydney, NSW 2142, Sydney
www.lkk.com.au
sales@lkk.co.nz
OCEANA
TM
GasMark
GMK10452

Advertisement

Table of Contents
loading

Summary of Contents for LKK LKK-1BSP

  • Page 1 OCEANA GasMark GMK10452 LKK Commercial Gas Stockpot User Manual P: (+64) 09 837 2960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz...
  • Page 2 • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 3: Table Of Contents

    • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 4: Installation & Operation Specifications

    Read this manual carefully before using the appliance. Keep the manual for future consultation after installation. This manual contains information regarding LKK’s commercial gas stockpots. See the appliance data plate positioned on the front control panel in order to identify the appliance product code.
  • Page 5 Size: Diemension Width (mm) Depth (mm) Height (mm) LKK-1BSP, 1BCSP & 1BMSP LKK-2BSP, 2BCSP & 2BMSP 1200 LKK-3BSP & 2BCSP & 3BMSP 1800 • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November...
  • Page 6 Please ensure the appliance is commissioned in accordance to the Manufacturers settings on the appliance data plate. Troubleshoot: If any of the following persist, gas or water leak, pilot not lighting, please call LKK for further assistance. Alternatively check page 12.
  • Page 7: Nominal Gas Consumption & Pressure

    Nominal Gas Consumption & Pressure Model MJ/hr Injector/mm Pressure/Kpa LKK-1BSP 18 x 1.35 1.00 LKK-1BCSP 24 x 0.95 0.90 LKK-1BMSP 32 x 1.10 1.00 LKK-2BSP 36 x 1.35 1.00 LKK-2BCSP 48 x 0.95 0.90 LKK-2BMSP 64 x 1.10 1.00 LKK-3BSP 54 x 1.35...
  • Page 8: Connection Points

    Gas inlet for all model high models is 270mm from fl oor and located on the left hand side of the appliance at the rear of the unit. LKK-1BSP - Duckbill Burner LKK-1BCSP - Chimney Burner LKK-1BMSP - Mongolian Burner...
  • Page 9: Installation Instruction & Specifications

    Australian Standard, “Gas Installations” any local Authority regulation and the Manufacturer’s installation instructions. Warning: Do not install LKK Gas Stockpot in marine environment. Some examples include on a boat or outdoor in the sea breeze. Doing so will result in unnecessary rust.
  • Page 10: Operating Instruction

    • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 11: How To Remove Front Panel

    • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 12: Troubleshoot

    Troubleshoot LKK Stockpot Troubleshoot Guide: - Servicing an LKK appliance should only be carried out by an authorised LKK gas technician or certifi ed plumber. - Any evidence of tamper will be void of warranty and not covered. Before issuing a service request check and assess the following: - Try to ignite unit and turn on, if it does not ignite follow instructions accordingly.
  • Page 13: Troubleshoot - Pilot Cover Installation

    • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 14: Troubleshoot - Adjusting Pilot Flame

    - These steps should only be carried out by a qualifi ed gas fi tter otherwise will result in a void of warranty. - All LKK Wok Burner Pilots are dual gas use and can be used for either NG or LPG.
  • Page 15: Duckbill Burner Maintenance

    2. Discard any unwanted dirt and grime. The nozzle shown above is an example LKK Duckbill Injector Cleaning Tool LKK Duckbill Injector Cleaning Tool of what can happen over time • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November...
  • Page 16: Warranty Terms & Conditions

    • Warranty is valid only if the appliance has been installed in accordance with local regulations by an authorised person, and the LKK installation instructions provided with the appliance. • LKK has the right to determine whether or not a fault is caused by faulty workmanship or material or that any parts are defective.
  • Page 17: Maintenance

    Maintenance Should be carried out by an authorized technician. Contact LKK Food Equipment for the nearest technician in your area. It is recommended that this appliance be serviced every 6 months by authorised service technician All normal care should be taken in up keep of gas equipment, make sure burners and gas cocks are cleaned after heavy daily use to prevent any major damage avoid spillage onto burners or gas cocks, if not sure call below numbers for advice.
  • Page 18 • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 19 • Specifi cations and design are subject to change without notice • Pictures are for illustrative purposes only • 2017 November P: (+64) 9 8372960 F: (+64) 09 836 9168 P: 1300 655 715 F: (+61) 02 8587 0033 18 Paramount Drive, Henderson, Auckland 47 George St, Clyde Sydney, NSW 2142, Sydney www.lkk.co.nz sales@lkk.co.nz www.lkk.com.au sales@lkk.com.au...
  • Page 20 New Zealand Phone: (+64) 09 837 2960 Fax: (+64) 09 836 9168 (Head Offi ce) 18 Paramount Drive, Henderson, Auckland www.lkk.co.nz sales@lkk.co.nz Australia Phone: 1300 655 715 Fax: (+61) 02 8587 0033 47 George St, Clyde, NSW 2142, Sydney www.lkk.com.au...

Table of Contents