Download Print this page
Vortec VORTEX COOLER 727SS Operation & Safety Instructions

Vortec VORTEX COOLER 727SS Operation & Safety Instructions

Advertisement

Quick Links

TABLE 1:
FILTER RECOMMENDATIONS
FILTER AND REPLACEMENT PART ITEM NUMBERS
Vortec Model
Oil Removal Filter
727SS-15H, 737SS
701S-48
727SS, 787SS
701S-48
727SS-35H, 787SS-35H
701S-54
747SS
701S-48
797SS
701S-48
797SS-35H
701S-54
TABLE 2:
DETERMINING COMPRESSED AIR LINE SIZE
1. Calculate total product compressed air consumption (SCFM, SLPM).
2. Determine length of compressed air line required for connection to main supply.
3. Locate pipe length in left column and read to the right to find the compressed air requirements.
4. Locate pipe size at top of column.
MAXIMUM AIRFLOW (SCFM) THROUGH PIPE AT 5 PSIG PRESSURE DROP (100 PSIG AND 70
Pipe Length
(Feet)
1/4
3/8
10
29
65
20
21
46
30
17
37
40
15
32
50
13
29
60
12
26
70
11
25
80
10
23
90
10
22
100
9
21
MAXIMUM AIRFLOW (SLPM) THROUGH PIPE AT 0.3 BAR PRESSURE DROP (6.9 BAR AND 21
Pipe Length
(Meters)
1/4
3/8
3
821
1840
6
594
1302
9
481
1047
12
425
906
15
368
821
18
340
736
21
311
708
24
283
651
27
269
623
31
255
594
Rubber hose maximum airflow rating: 1/2" I.D. rubber hose = 3/8" pipe; 3/4" I.D. rubber hose = 1/2" pipe
LIT
LIT0161
Valve & Thermostat Kit
Valve & Thermostat Kit
(120 VAC)
721T-70
721T-70
721T-100
-
-
-
Pipe Size (Nominal) - Schedule 40
1/2
3/4
1
120
254
480
85
180
340
70
147
277
60
127
240
54
114
215
49
104
196
46
96
181
43
90
170
40
85
160
38
80
152
Pipe Size (Nominal) - Schedule 40
1/2
3/4
1
3396
7188
13584
2406
5094
9622
1981
4160
7839
1698
3594
6792
1528
3226
6085
1387
2943
5547
1302
2717
5122
1217
2547
4811
1132
2406
4528
1075
2264
4302
Replacement Generator Kits
(240 VAC)
(5 pc)
721T-80
208GK-15H
721T-80
208GK-25H
721T-110
208GK-35H
721T-80
208GK-15H
721T-80
208GK-25H
721T-110
208GK-35H
O
F)
1-1/4
1-1/2
2
978
1483
2863
692
1049
2024
565
856
1653
489
792
1431
437
663
1280
399
606
1169
370
561
1082
346
524
1012
326
494
954
309
469
905
O
C)
1-1/4
1-1/2
2
27677
42117
81023
19584
29687
57279
15990
24225
46780
13839
20999
40497
12367
18763
36224
11292
17150
33083
10471
15877
30621
9792
14829
28640
9226
13980
26998
8745
13273
25612
OPERATION & SAFETY
OPERATION & SAFETY
INSTRUCTIONS
INSTRUCTIONS
VORTEX COOLER
Models 727SS, 727SS-15H, 727SS-35H,
737SS, 747SS, 787SS, 797SS,
787SS-35H, 797SS-35H
(Includes all BSP versions of models listed above)
2-1/2
4536
3208
2619
2268
2029
1852
1715
1604
1512
1435
2-1/2
128369
I M P O R TA N T
I M P O R TA N T
90786
74188
Please read all instructions BEFORE
Please read all instructions BEFORE
64184
attempting to use this product
attempting to use this product
57421
52412
48535
45393
42790
40611
10125 Carver Road, Cincinnati, OH 45242
Phone: 513-891-7474 • Fax: 513-891-4092
Toll Free: 800-441-7475
www.vortec.com • techsupport@vortec.com
- UL TYPE 4X
TM

Advertisement

loading
Need help?

Need help?

Do you have a question about the VORTEX COOLER 727SS and is the answer not in the manual?

Questions and answers

Summary of Contents for Vortec VORTEX COOLER 727SS

  • Page 1 13273 25612 40611 10125 Carver Road, Cincinnati, OH 45242 Phone: 513-891-7474 • Fax: 513-891-4092 Rubber hose maximum airflow rating: 1/2” I.D. rubber hose = 3/8” pipe; 3/4” I.D. rubber hose = 1/2” pipe Toll Free: 800-441-7475 www.vortec.com • techsupport@vortec.com LIT0161...
  • Page 2 Filters should be installed in the 2. Water vapor in the compressed air supply. compressed air supply line as close as possible to the Vortec 3. Loose cold cap. This may occur if not tightened properly product.

This manual is also suitable for:

Vortex cooler 727ss-15hVortex cooler 727ss-35hVortex cooler 737ssVortex cooler 747ssVortex cooler 787ssVortex cooler 797ss ... Show all