READ THIS PAGE FIRST WATER CONDITIONER BASICS SOFTENER SYSTEM SPECIFICATIONS SOFTENER SYSTEM DIMENSIONS UNPACK & INSPECT YOUR WATER SOFTENER CHECK THE VALVE SERIAL NUMBER CHECK THE SOFTENER SERIAL NUMBER PARTS BREAKDOWN PRE-INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WATER BYPASS PROGRAMMING GUIDE START-UP INSTRUCTIONS MAINTENANCE INSTRUCTIONS TROUBLE SHOOTING GUIDE...
When properly installed and maintained, it will give years during installation. Do not use pinched or damaged of trouble free service. o-rings during installation. Atlas Filtri Engineering reserves the right to change the specifications referred to in this literature at any time, without prior notice. EXAMPLE:...
WATER CONDITIONER BASICS WHAT IS HARD WATER AND HOW IT IS SOFTENED All of the fresh water in the world originally falls as rain, 2. PARTICULATE IRON—Also called ferric or colloidal snow, or sleet. Surface water evaporates and is drawn iron.
SOFTENER SYSTEM SPECIFICATIONS BNT850SE UF VALVE Performance Data Sheet and Specifications Model CS16H-1017 CS16H-1035 Control System BNT-850SE UF Control Valve Regeneration Type UP Flow Integrated Meter in Bypass Hardness Removal(6 lb/cf Salt Dosage) 704 Gram 1408 Gram Media Loaded Resin Quantity 12.5 L 25 L Resin Type...
UNPACK & INSPECT YOUR WATER SOFTENER Inspect the water softner for any shipping damage. If damage is found, notify the transportation company and request a damage inspection. Damage to cartons should also be noted. Handle the softener unit with care. Do not drop the unit or set on sharp, uneven projections on the floor. Do not turn the softener unit upside down.
CHECK THE VALVE SERIAL NUMBER Check to make sure the valve type matches what you ordered. The valve configuration sticker will show the injector, BLFC and DLFC size. The valve model sticker shows model, hardware/software version, serial # and batch code of the control valve. Serial numbers are important for troubleshooting.
CHECK THE SOFTENER SERIAL NUMBER 00299407N890001 00299407N890001 Valve Part # Year Month Date Batch code (00299407): Softener part # (N)YEAR: "N" stand for year 2017, "M" stand for year 2016, "L" stand for year 2015, "K" stand for year 2014... (8)MONTH: 1(JAN), 2(FEB), 3(MAR), 4(APRIL), 5(MAY), 6(JUNE), 7(JULY), 8(AUG), 9(SEP), A(OCT), B(NOV), C(DEC) (9)DATE: 1 2 3 4 5 6 7 8 9 (A)10 (B)11 (C)12 (D)13 (E)14...
PARTS BREAKDOWN SOFTENER PARTS LIST Part # Description 21710110 Pressure Tank Clamp 07591035 1035 Pressure Tank 07501017 1017 Pressure Tank 02030016 Distribution Assy-1035 02030018 Distribution Assy-1017 07060009 Top Cone 22018603 Control Valve Assy 05030044 Controller Back Cover(Black) 21709003 Secure Clip 22053013B Bypass Valve Assy 07030498...
Page 12
VALVE BODY PARTS LIST B13 05031013M Injector Holder Plug B14 05056156 Injector Nozzle Plug 05031010M BLFC Holder 05056206M BLFC(0.2GPM)(Optional) 05031033 O-ring of BLFC Holder 05056134 O-ring of Brine Line Elbow 05056172N Secure Clip-S 30110004M Tube Insert 21389033M Brine Line Elbow Nut 30020013M Brine Line Elbow 05056180M Brine Valve Injector Stem Assy 1...
Page 13
POWER HEAD PARTS LIST Part # Description 05030005 Bnt85HE Base 85HE Main Gear 05031008M Washer on Main Gear 05056139 Screw on Main Gear 13000426 05030009M Motor Gear 05031006 Mounting Plate 05056084 Screws on Mounting Plate 05056098 Motor Pin Magnet 05010023 05056550 Motor 05031009...
Page 14
BYPASS PARTS LIST Part # Description 05056129 O-ring-φ23×3 05010083 Adaptor Distributor 05056025 Adaptor Coupling 26010046 O-ring-φ27×3 05010106 Impeller Holder 02170055 Meter Assy 05040129 Meter Ball 05010019B Bush 02170264 Meter Spare Parts 05056044B SS Clip 13000327 Screw M4×12 05056134 O-ring(12×2) 05056146 Bypass Plug 21709004 Shaft Clip...
PRE-INSTALLATION INSTRUCTIONS Contact your local distributor to have a complete water analysis and check your water hardness on your water supplier, this will keep your conditioner in proper working. Cold Soft Water Electrical Panel Hot Soft Water Hard Filtered Water Ground Strap Ground Strap Raw Water...
Page 16
TOOLS REQUIRED FOR INSTALLATION: Two adjustable wrenches. Additional tools may be required if modifications to home plumbing are required. Use copper, brass, or PEX pipe and fittings. Some codes may also allow PVC plastic pipe. Refer to local codes. Always install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn off water to the softener for repairs, but still have water in the house pipes.
WATER BYPASS In case of an emergency such as softener maintenance, you can isolate your water softener from the water supply using the bypass valve located at the back of the control. In normal operation the bypass is open with the ON/OFF knobs in line with the INLET and OUTLET pipes. To isolate the softener, simply rotate the knobs to the BYPASS position.
PROGRAMMING GUIDE FAMILIARIZE WITH KEY PAD CONFIGURATION MENU CONFIRM DOWN This function enters the basic set up information required at the time of installation. MENU This function is to press and select one item to change and accepts the values if changed.
Page 19
ADVANCED SETTINGS DISPLAY System Regenerate Based On System Regenerate Based On Automatic Calculation: Manual Settings: Regeneration Water Regeneration Regeneration Regeneration Regeneration Mode Time Capacity Mode Time Days Regeneration Restore Regeneration Data Regeneration Restore Defaults Cycle Days Defaults Entry Cycle PARAMETER DESCRIPTION Time Crrent Time setting.
Page 20
SYSTEM INFORMATION PAGE When you enter system information setting, system key information can be viewed in this page. System Information System Information System Information Total Treated Water Regeneration Time Total Regenerations 0 Gallons 02:00 AM 0 Times System Information System Information System Information Water Capacity Capacity Remaining...
START-UP INSTRUCTIONS 1. Add two liters of water into the cabinet at the time of installation. This is for the unit to achieve proper capacity in the first time of regeneration . 2. Plug the power transformer into an approved power source. Connect the power cord to the valve. 3.
Page 22
01:34 Manual Regen. Last Regen. : Oct. 11, 2017 4.5 Press CONFIRM key to confirm Mode : Meter Delayed and press MENU key to have an DELAY manual regeneration. Capacity IMMEDIATE Remaining Flow Rate NOTE: If you select “DELAY” option,the valve will start to regenerate at the closest day's REGEN. TIME (default is 02:00) 5.
MAINTENANCE INSTRUCTIONS CHECK THE SALT LEVEL Check the salt level monthly. Remove the lid from the cabinet or brine tank, make sure salt level is always above the brine level. NOTE YOU SHOULD NOT BE ABLE TO SEE WATER IN THE CABINET OR BRINE TANK. ADDING SALT Use only clean salt labeled for water conditioner use, such as crystal, pellet, nugget, button or solar.
Page 24
SERVICE THE BNT850SE CONTROL VALVE WARNING CAUTION Electrical shock Hazard! Disassembly while under pressure can result unplug the unit before removing the cover or servicing the valve. accessing any internal control parts. Before Servicing 1. Turn off water supply to conditioner using the bypass tool attached on the bypass. Close the inlet and outlet Bypass tool...
Page 25
REPLACE TIMER 2 X Screws Disconnect the wires Disconnect meter cable 1. Disconnect the meter cable from the 2. Remove the two screws from the valve 3. Remove the cover of the valve and meter. (If meter cable is attached). cover.
Page 26
REPLACE METER 2 X Screws 2 X Clips Disconnect meter cable 2. Disconnect the bypass from valve by removing clips. 1. Disconnect the meter cable from the meter. (If flow meter cable is attached) Meter Support C o u p l i n g Adapter Meter 3.
Page 27
REPLACE DRAIN LINE FLOW CONTROL Drain Line Elbow 1. Pull the drain line clip and remove the drain line elbow and washer. 2. Clean/replace drain line flow control . Drain Line Clip DLFC REPLACE BRINE LINE FLOW CONTROL Brine Line Elbow Assy 1.
Page 28
REPLACE CIRCUIT BOARD 4 X Screws 1. Follow steps 1 to 3 of timer /Powerhead replacement. 2. Remove all the connections on PCB. 3. Remove the four screws from the PCB. 4. Replace the PCB. REPLACE DISPLAY Disconnect the wire conncetions &...
TROUBLE SHOOTING GUIDE Problem Possible Solutions 1. CONDITIONER DELIVERS HARD WATER A. Bypass valve is open A. Close bypass valve B. No salt in brine tank B. Add salt to brine tank and maintain salt level above water level C. Injector or screen plugged C.
Need help?
Do you have a question about the AQUARIUS CS16H-1017 and is the answer not in the manual?
Questions and answers