ECG Slave Cable & Adapter Kit User Guide...
Page 2
T: 1-888-482-9449 or 1-425-951-1200 The Netherlands Australia F: 1-425-951-1201 Sonosite and the Sonosite logo are trademarks and registered trademarks of FUJIFILM Sonosite, Inc. in various jurisdictions. All other trademarks are the property of their respective owners. Part Number: P20162-01 Publication Date: October 2015...
SonoSite ultrasound system, without having to add extra leads/sensors to the patient. The ECG slave cable and adapter kit contains the ECG slave cable and ECG adapter cable. The ECG slave cable and adapter kit are approved for use with the SonoSite ECG module and SonoSite ultrasound products.
For labeling symbols used, see the ultrasound system user guide. Warranty statement The ECG slave cable and adapter cable are warranted for material and workmanship only, for a period of 12 months from date of shipment from FUJIFILM SonoSite. The warranty does not cover damage caused by misuse by the end user, disinfecting or sterilizing incorrectly or with chemicals not recommended by FUJIFILM SonoSite, or circumstances beyond what is considered normal for the product’s intended application.
The ECG slave cable includes the following components: ECG slave cable Adapter cable P19958-01 P06917-50 Figure 2-1 ECG slave cable components and part numbers Intended uses The ECG slave cable is intended to work with SonoSite ultrasound equipment and the SonoSite ECG module.
Figure 2-2 ECG module The ECG Slave Cable Kit shall be able to receive an ECG signal from the following physiological/ECG patient monitors: Use the ECG slave cable only with ECG monitors or physiological equipment that has Caution been approved for use with the ECG slave cable kit.
ECG Slave Cable and Adapter Kit User Guide Inspecting contents After unpacking the contents, perform a visual and tactile inspection of the ECG slave cable and adapter cable. Contact FUJIFILM SonoSite or your local representative immediately to report any damage or discrepancies.
Setup and use Setting up the ECG slave cable and adapter cable Only use the ECG slave cable and adapter kit with an approved Caution SonoSite ECG module. Use the ECG slave cable only with ECG monitors or physiological equipment that has been approved for use with the ECG slave Caution cable kit.
Page 12
3 If connecting to a Philips Intellivue MP70 patient monitor, plug the ECG slave cable into the patient monitor. 4 If connecting to a GE Solar 8000i patient monitor, do the following: a Plug the ECG slave cable in to the adapter cable.
Operating the ECG slave cable For best results when using the ECG slave cable, the output of the patient monitor should be 5V peak-to-peak AC-coupled. To prevent misdiagnosis, do not use the ECG trace to diagnose cardiac rhythms. The WARNING FUJIFILM SonoSite ECG module and slave cable is a non-diagnostic accessory.
To clean and disinfect the ECG slave cable and adapter cable (wipe method) 1 Remove the cable from the system. 2 Examine the ECG slave cable and adapter cable for damage, such as cracks or splitting. 3 Clean the surface using a pre-moistened wipe, or a soft cloth lightly dampened with a mild cleaning solution.
Temperature: -35 º C to 65 º C Humidity: 15% to 95% Atmospheric pressure: 500 hPa to 1060 hPa. Disposing of the ECG slave cable Contact FUJIFILM SonoSite or your authorized representative for disposal instructions. Chapter 4...
Safety Patient safety is ensured only when a well-designed product is used in a safe and responsible manner. The ECG slave cable & adapter kit is designed to function in the following operating environment: Temperature: 10 ºC to 40 ºC Humidity: 15% RH to 95% RH...
Page 18
Symbol Definition Corrugated recycle. Manufacturer. Do not get wet. Fragile. Paper recycle. Temperature limitation. Atmospheric pressure limitation. Humidity limitation. Follow instructions for use. Chapter 5...