Mitsubishi Electric MA-E85R-E Instruction Manual page 8

Hide thumbs Also See for MA-E85R-E:
Table of Contents

Advertisement

Available languages

Available languages

Preparation
Take the activated charcoal filter out of its plastic bag and then install it.
1
Remove the inlet panel.
Pull the inlet panel toward you
while pressing the levers at the
bottom.
2
Remove the filters.
1 Pre-filter unit
Turn the knobs on the left and right and then remove the pre-
filter unit.
2 HEPA filter
3
Remove the activated charcoal filter and
then take it out of its plastic bag.
The distribution of charcoal may be uneven and there may be
black charcoal powder in the plastic bag, but this will not affect the
performance.
8
4
Attach the filters to the main unit.
1 Activated charcoal filter
Push the filter all the way in
(there is no front and back).
Position the tab so
that it is protruding
out toward you.
Do not push this surface downward.
This may cause deformation.
3 Pre-filter unit
Insert the tabs at the bottom in the two holes in the main unit
and then set the knobs on the left and right to the lock position.
Knob
Tab on dust box unit
Confirm that the knob on the left
side is positioned over the tab on
the dust box unit.
5
Attach the inlet panel to the main unit.
Align the inlet panel with both edges of the main unit and then
hook the two tabs at the top of the inlet panel onto the main unit
and firmly push in the bottom.
Tabs at top (2
places on back
side)
Write the filter use start date on the filter replacement sticker on the
right side of the main unit.
2 HEPA filter
Confirm the installation
orientation and then push
the filter all the way in.
Holes in main unit (2 places)