Geostar ASTON Series Installation Manual page 33

Heating | cooling | hot water
Hide thumbs Also See for ASTON Series:
Table of Contents

Advertisement

Wiring Schematics cont.
Dual Capacity Split with Aurora Advanced - 208-230/60/1 cont.
Cap
Unit Power Supply
208-230/60/1
G
EH1
CC2
P2
ES
LS
ALM
K5-Alarm
ALG
Relay
ACC COM
ACC NO
ACC NC
LO
R
C
O/B
G
Y1
Y2
W
DH
P1
R
Green(11)
ASTON & ASTON ADVANCED DUAL-CAPACITY OUTDOOR SPLIT SERIES INSTALLATION MANUAL
Blue
Compressor
Red
S
C
Blue
Black
Pink
R
Tan(6)
CT
Black
CT
T2
T1
CC
L2
L1
CC2
P9
R
F FG CC CCG
CC
C
HI
F
K6-Acc
Aurora Base Control
Relay
Com2
Com1
LED5
LED5
G
G
RS485 NET
RS485 NET
C
C
C
R
-
+
P8
P7
Run Winding
IntelliStart
Active
Start
Common
UltraTech
RV
FP1
CS
RCP
470 Ohm
Resistor
CC2
CC2
P5
REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS
LO
G
Status
SW1
LED3
G
(ABC)
Test Mode
RS485 EXP
Y1
G
CC
R
+
CO
E
1 H
C
E
2 H
-
C
P6
P3
33
Duel Fuel Wiring Diagram
Thermostat
Using Field Installed Relay
Y1
1st Stage Compressor
Y2
2nd Stage Compressor
O
Reversing Valve
Fossil Fuel
L
Fault Signal
Furnace
C
C
Common
Common
R
R
24 VAC
24 VAC
W
Auxiliary Heat Relay
G
G
Fan
Auxiliary
Heat Relay
W
Auxiliary Heat Relay
Note 1: Field installed SPST dual fuel relay
(Required for dual fuel installation)
Aurora LED Flash Codes
Slow Flash
1 second on and 1 second off
Fast Flash
100 milliseconds on and 100 milliseconds off
Flash Code
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Random Start Delay (Alternating Colors)
Configuration LED (LED2, Yellow)
Status LED (LED1, Green)
Fast Flash
No Software Overide
Configuration LED (LED2, Yellow)
Fast Flash
DIP Switch Overide
Fault LED (LED3, Red)
Fast Flash
Fault LED (LED1, Red)
Status LED (LED3, Green)
Normal Mode
OFF
Normal Mode
Input Fault Lockout
Flash Code 1
Control is Non-Functional
High Pressure Lockout
Flash Code 2
Test Mode
Low Pressure Lockout
Flash Code 3
Lockout Active
Future Use
Flash Code 4
Dehumidification Mode
Freeze Detection – FP1
Flash Code 5
Future Use
Reserved
Flash Code 6
Future Use
Condensate Overflow Lockout
Flash Code 7
Load Shed
Over/Under Voltage Shutdown
Flash Code 8
ESD
Future Use
Flash Code 9
Future Use
Future Use
Flash Code 10
FP1 Sensor Error
FP1 and FP2 Sensor Error
Flash Code 11
LP
HP
P4
C
R
F1-3A
F
PWM
CFM
C
Fault
LED1
P13
R
Off
On
FP1 – 15°F/30°F
1
FP2 – 15°F/30°F
2
RV – B/O
3
Acc – Dip 4
4
Acc – Dip 5
5
CC – Dual/Single
6
L Output Type
7
8
Future Use
SW2
Config
LED2
Y
Split
Y1
Y2
O
P1
LO
C
R
P2
ES
= chassis
OFF
Slow Flash
ON
OFF
Slow Flash
Fast Flash
Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5
Flash Code 6
Flash Code 7

Advertisement

Table of Contents
loading

Related Products for Geostar ASTON Series

This manual is also suitable for:

Aston advanced series

Table of Contents