Download Print this page

Bayco 675 Instruction Manual

13 watt fluorescent work lights

Advertisement

Quick Links

Instruction Manual
Models 675 / 676 / 677
13 Watt Fluorescent Work Lights
Electrical Rating - All models use 125 Volts 60 Hz
CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK AND FIRE - PULL
PLUG
WHEN SERVICING, OR WHEN RE-LAMPING - USE ONLY 13 WATT OR SMALLER
BULB
CAUTION
DO NOT use in explosive atmospheres, near flammable liquids, or where explosion
proof lamps are required.
DO NOT use in the proximity of vehicles or equipment when there is a risk of
flammable liquids coming into contact with the hand lamp.
DO NOT immerse in water.
DO NOT use in areas where water can accumulate or in rain or mist.
CAUTION:
Risk of Electric Shock – For Light Duty Dry Location Use Only.
IMPORTANT SAFETY INSTRUCTIONS:
This product has a polarized plug (one blade is wider than the other). As a safety
feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in
the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use
with an extension cord unless the plug can be fully inserted. Do not attempt to defeat
this safety feature.
WARNING: NOT FOR USE IN HAZARDOUS LOCATIONS
CAUTION: DO NOT USE IN HAZARDOUS LOCATIONS AS REQUIRED BY THE
CANADIAN ELECTRICAL CODE, PART I
OPERATION
Plug into 120 Volt 60 Hz polarized outlet. Notice the polarized plug and insert
properly. Operate switch. Lamp may flash several times before lighting.
Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.baycoproducts.com
BULB REPLACEMENT
1. Disconnect the light from electrical outlet
2. Remove the plastic cover from the cord end of the light.
3. Use the edge of a knife blade to lift out the plastic rivet at the top of the handle.
4. Carefully pull the tube from around the bulb-holder. The bulb will remain in the socket.
5. Carefully pull up on bulb to remove and discard the old bulb.
6. Insert new bulb in socket in bulb holder. Be sure bulb is properly seated against the
bulb-holder.
7. Slide the tube assembly over the bulb and insert top of bulb into the oval slot in the
top of the bulb holder. Bulb should just penetrate slot.
8. Align the holes in the tube with the holes in the bulb-holder handle and install both
plastic rivets. Press firmly until seated.
9. Replace the plastic cover aligning the cover to fit over the on / off switch.
10. Restore power connection and test lamp by pressing the power switch.
NOTE: EVEN NEW LAMPS WILL FLASH SEVERAL TIMES BEFORE LIGHTING.
REPLACEMENT BULBS
Use PL-13 twin-tube fluorescent bulb.
A replacement lamp may be obtained from Bayco products.
WARRANTY
1 YEAR WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in workmanship
and materials to the original purchaser for 1 year from the date of purchase, and includes
the LEDs, housing, lenses, electronics, switches, rechargeable batteries and chargers.
Bulbs (other than LEDs) are covered for 90 days from the date of purchase.
We will repair or replace this product should we determine it to be defective. This is the
only warranty, expressed or implied, including any warranty of merchantability or fitness for
a particular purpose.
For a complete copy of the warranty, go to www.baycoproducts.com/bayco-product-
support/warranties. Retain your receipt for proof of purchase.
Instructions Pour les
Modèles 675 / 676 / 677
13 Watt Lampes de Travail Fluorescente
Caractéristiques électriques - Tous les modèles utilisent 125 volts 60Hz
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE ET INCENDIE
- RETIRER LA FICHE
LORS DE L'ENTRETIEN, OU LORS D'UNE NOUVELLE LAMPING - UTILISER
SEULEMENT 13 WATTS OU MOINS AMPOULE
ATTENTION
NE PAS utiliser dans des atmosphères explosives, près de liquides inflammables,
ou lorsque des lampes antidéflagrantes sont nécessaires.
NE PAS utiliser à proximité de véhicules ou d'équipement quand il ya un risque de
liquides inflammables entrent en contact avec la lampe de poche.
Ne pas plonger dans l'eau.
NE PAS utiliser dans les zones où l'eau peut s'accumuler ou dans la pluie ou le
brouillard.
ATTENTION: Risque de choc électrique - Pour la lumière endroit sec Duty Utilisez
uniquement.
CONSIGNES DE SÉCURITÉ IMPORTANTES
Ce produit a une fiche polarisée (une lame est plus large que l'autre). Par mesure
de sécurité, cette fiche ne rentre dans une prise polarisée que dans un sens. Si la fiche
n'entre pas complètement dans la prise, inverser la fiche. Si elle ne convient toujours
pas, contactez un électricien qualifié. Ne pas utiliser avec une rallonge si la fiche peut
être insérée à fond. Ne pas essayer de contourner ce dispositif de sécurité.
ATTENTION: NE PAS UTILISER DANS DES ENDROITS DANGEREUX
ATTENTION: NE PAS UTILISER DANS DES ENDROITS DANGEREUX AS REQUIS
PAR
LE CODE ELECTRIQUE CANADIEN, PARTIE I
INS-SL-675-677-18

Advertisement

loading

Summary of Contents for Bayco 675

  • Page 1 Plug into 120 Volt 60 Hz polarized outlet. Notice the polarized plug and insert LE CODE ELECTRIQUE CANADIEN, PARTIE I properly. Operate switch. Lamp may flash several times before lighting. Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.baycoproducts.com INS-SL-675-677-18...
  • Page 2 NO lo use en áreas donde el agua se puede acumular o en la lluvia o la niebla. PRECAUCIÓN: Riesgo de descarga eléctrica - For Light lugar seco Deber uso exclusivo. Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.baycoproducts.com INS-SL-675-677-18...

This manual is also suitable for:

676677