Control Panel - Rowenta AU50 F0 Series Instructions For Use Manual

Hide thumbs Also See for AU50 F0 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
EN

CONTROL PANEL

Power Control (A)
The power control turns the unit on and off. After switching the air conditioner off, you must wait 3
minutes before switching it back on again.
Warning Light "FULL " (B)
Condensed water may accumulate in the unit.
If the internal tank becomes full, the warning light will come on and the unit will stop operating until
the unit has been drained (evacuation #9).To drain the unit, refer to storage instructions p.2.
Timer (C)
Auto turn OFF : with the machine in running mode, press the timer button.Then set the desired wor-
king time in hours before shut down by pressing the "+" or "-" buttons.
Auto turn ON: With the machine in OFF mode, press the timer button.Then set the desired time de-
lay ON in hours by pressing the "+" or "-" buttons before the unit automatically starts running in the
latest used mode.
The time is adjustable between 1 to 24hours
Mode Control (D)
The mode control has four settings. A light indicates which mode is currently being used.
• Cooling mode
: During the cooling mode the air is cooled and hot air is expelled through the
heat exhaust hose (#12). Adjust fan speed and air temperature to suit your desired comfort level.
Use the buttons (-) and (+) to set the desired temperature between 16 and 32°C. After 10 seconds
the display will revert to room temperature.
Note: the air exchange hoses must vent outside the room when using cooling mode.
• Eco mode
: In this mode, the targeted temperature is automatically set up -3°C vs the room
temperature to save energy.The speed is automatically defined. After 3 seconds the display will
revert to room temperature.
• Dehumidify mode
cooling mode. In this mode, If temperature is higher than 25°C, fan speed can be adjusted;
otherwise, fan speed is fixed to "low" .
In this mode, do not connect the exhaust hose and let the warm air return to the room.You will
need to drain the unit to evacuate the water : refer to storage instructions p.2. for installation.
• Fan Mode
: air is circulated throughout the room with no cooling.The air exchange hose does
not need to be installed in this mode Adjust fan speed to suit your desired comfort level.
Fan Speed Control (E)
The fan speed control has three settings: High, Medium and Low.
(B)
FULL
(A)
(C)
(D)
: Air is dehumidified as it passes through the unit, without being in full
(E)
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Au5010f0Au5020f0Turbo cool au50 f0 seriesTurbo cool au5010f0Turbo cool au5020f0

Table of Contents