Installation
For best ground connection, connect to grounded lead
in service panel or to metal underground water pipe or
well casing at least 10 ft. long. If plastic pipe or insulated
fittings are used, run ground wire directly to metal well
casing or use ground electrode furnished by the power
company.
To Connect Line and Motor
Risk of electrical shock. Disconnect power
at service panel before connecting pressure switch to
pump. Do not operate pump unless motor and pressure
switch are connected to each other by a solid metal
connection and are grounded.
1.
Remove device cover.
2. Connect green ground wires from both the LINE and
MOTOR wiring to the green ground wire in the device
with a wire nut of size and type specified by approved
local or national codes. See Figure 1 and Table 1.
3. Using the included wires and wire nuts of size and
type specified by approved local or NEC national
codes, connect power supply leads to switch
terminals marked LINE. See Figure 1 and Table 1.
4. Using the included wires and wire nuts of size and
type specified by approved local or national codes,
connect motor leads to switch terminals marked
MOTOR. See Figure 1 and Table 1.
5. Replace device cover.
6. Pentek CSC is now wired for operation.
Watertight conduit connections must be
used when exposed to direct weather, moisture or high
humidity.
COMMISSIONING
Pentek CSC requires two easy steps to commission it for
use: Online Registration and WiFi connection.
NOTE: It is important that the commissioning steps be
done in the order listed in this manual. The device may
be paired with, and controlled from, either a smartphone/
tablet or computer. The smartphone, tablet or computer
you wish to use to pair the Pentek CSC with the
homeowner' s router must be within range of the device
during the pairing processes described below.
Online Device Registration
New users can download the Link2O™ app to their
smartphone or tablet from the app store or access the
website from a computer at www.MyLink2o.com.
1.
Navigate to the web page or open the app.
2. Existing users: Login to your account and click
DEVICES and then ADD NEW DEVICE.
3. New users: Click Sign Up on the web page or scroll
down on the app and click SIGNUP AS A CUSTOMER.
4. Follow prompts to enter device and system
information and complete online device registration.
NOTE: The unique device ID code is required for this step.
The ID code can be found either on the inner cover of the
device or on the front of this manual.
Connection
Line Side
Connections
Figure 1: Device Wiring
Device Wiring
Ground
Device Ground (Green) + Motor Ground (Green) +
Connections
Line Side
Connections
Motor Side
Connections
Table 1: Device Wiring
Ground
Motor Side
Connections
Line Ground (Green)
Line (Black) + Device (Yellow)
Line (White) + Device (Yellow)
Motor (Black) + Device (Yellow)
Motor (Black) + Device (Yellow)
4