Sound & Vision..............22 Ending the bathing cycle ............. 24 Disinfect bath after each resident........24 Using a Standing & Raising Aid with Parker® ......26 Resident transfer from Sara 3000™ to Parker ....26 Using a Ceiling lift with Parker ..........28 Resident transfer from a ceiling lift to Parker ......
Contact ArjoHuntleigh for replacement parts. Contact information appears on the last page of ArjoHuntleigh Equipment. this IFU. Your Parker is part of a series of quality prod- ucts designed especially for hospitals, nursing Definition in this IFU: homes and other health care uses.
Installation & Service leigh representative. requirements This bath is intended for assisted bathing and The Parker must be installed by appropriately showering of adult residents in care facilities trained personnel according to the Assembly and (excluding use at home). Installation Instructions, requirements in the...
Safety Instructions WARNING To avoid injury to both resident and caregiver, never modify the equip- ment or use incompatible parts. WARNING To avoid explosion or fire, never use the equipment in oxygen rich environ- ment, in presence of heat source or flammable anaesthetic gases.
Site preparations Make sure the Parker thermostatic mixer has been calibrated according to the Assem- Prior to installation of Parker bath the bly and Installation Instructions by quali- floor and walls within the required area fied personnel or an ArjoHuntleigh must be finished.
Control Panel 14 15 Parker 8 Fill ON/OFF 1 LED for shower indication (Auto fill option) 2 Filling water and Shower temperature dis- 9 Shower ON/OFF play with scalding protection 10 Air Spa - whole tub ON/ Intensity/OFF 3 Bath water temperature display with (option) scalding protection.
Hand Controls Parker Hand Control 1 Raise bath 2 Lower bath 3 Tilt bath to upright position 4 Tilt bath to reclined position 5 Air Spa - whole tub ON/ Intensity/OFF (option) 6 Air Spa - foot well ON/ Intensity/OFF (option) Sound &...
Auto fill function (option) clockwise. (See Fig. 4) If the emergency stop button was used due to an A Parker equipped with auto fill function, pre- equipment error, stop using the bath and contact fills the footwell. (See Fig. 2) an ArjoHuntleigh technician.
• To get colored light in the tub, press the Door lock S&V light button on the S&V hand control. The Parker has a door handle that works as a • Press the S&V light button one more door lock.The door handle needs to be aligned time to change light colour.
Disinfection unit (option) Battery charge level when the main power supply is not connected. The Parker has the a built in disinfection unit as an option. (See Fig. 1) There is a disinfectant bottle with an adjustable Yellow LED on...
(See Fig. 2) If needed, help the resident get seated in the 3 Parker with fill: start filling the footwell by Parker.(Fig. 4) pressing the tub filling button. (See Fig. 3) Continue with the steps on the back of the next •...
• Parker with Auto fill: The filling stops If needed, help the resident to place their automatically after 60 seconds. feet into the footwell. (See Fig. 1) To stop filling within this time frame, press auto fill button.
Air Spa (option) 19 The top display shows the shower water temperature. Allow a few seconds for the display to adjust the temperature. If needed, 25 To activate the Air Spa, use either the but- turn the knob to adjust the water tempera- tons on the control panel or on the hand con- ture.
Ending the bathing cycle Disinfect after each resident 27 When bathing is complete, drain the bath 36 Make the bath ready for the next resident. tub by opening the drain. The bath must be fully disinfected after each use to prevent cross-contamination. •...
Using a Standing & Raising Aid with Parker The Parker can be used together with Arjo- 15 If needed, gently, spin the resident around Huntleigh standing and raising aids such as and place his or her feet in the footwell.
Using a ceiling lift with Parker The Parker can be used together with Arjo- 9 Make sure to feel the water temperature and Huntleigh Ceiling lift, Maxi Sky 600 with a adjust, if needed. (See Fig. 2) 2-point spreader bar, using a mesh sling with or 10 Perform the bathing (See chapter, Operat- without head support.
Huntleigh Customer Service located on the read the material safety data sheet of inside of the last page. the disinfectant. If the Parker is equipped with Air Spa, the bath must be disinfected with its integrated disinfec- WARNING tion system.
Page 31
• Clean and disinfect the bath tub according to the IFU before the first bath of the day and after the bath of each resident. Do not forget to contact ArjoHuntleigh for the annual Preventive Maintenance visit.
Page 32
• Arjo Clean • Arjo General Purpose Disinfectant • Arjo Disinfectant Cleanser IV or • Cen-Kleen IV 1 Make sure that Parker is in an upright posi- tion. (See Fig. 1) 2 Open the compartment for disinfectant bottle. (See Fig. 2) 3 On the disinfectant bottle: •...
Page 33
Arjo Disinfectant Cleanser IV (60 Arjo General Purpose Disinfectant (35) Arjo Clean (30) Cen-Kleen IV (30...
Page 34
(particularly behind the head), metal sensory knobs, door seals and the hand control with a cloth soaked in dis- infectant solution. 9 Raise the Parker to upright position. 10 Rinse all parts clean with cold water using the shower. (See Fig. 4)
Page 35
Arjo Disinfectant Cleanser IV (60 Arjo General Purpose Disinfectant (35 Arjo Clean (30 Cen-Kleen IV (30...
Page 36
(See Fig. 2) Additional steps 16-21 for Air Spa only: 6 Open the drain and empty any left over 17 The Parker must be tilted backwards to water so that the water sensory knobs do not disinfect through all nozzles.
Page 37
Arjo Disinfectant Cleanser IV (60 Arjo General Purpose Disinfectant (35 Arjo Clean (30 Cen-Kleen IV (30...
Page 38
Additional steps 27-31 for Air Spa only: 39 Rinse thoroughly with water until no resid- ual disinfectant is visible. 27 The Parker must be tilted backwards to rinse through all nozzles. 40 Leave to air dry so that the bath is clean, dis-...
Page 40
Clean step 15. Additional steps 10 - 14 for Air Spa only: WARNING 10 The Parker must be tilted backwards to dis- To prevent cross-contamination, infect through all nozzles. always follow the disinfection instruc- tions in this Instructions for Use.
Page 41
Arjo Disinfectant Cleanser IV (60 Arjo General Purpose Disinfectant (35 Arjo Clean (30 Cen-Kleen IV (30...
Page 42
32 Leave to air dry so that the bath is clean, dis- infected and ready to be used the next morn- ing. 20 The Parker must be tilted backwards to rinse through all nozzles. 21 Place the water spray handle into the disin- fectant/rinsing inlet and turn either way to secure it (some force may be needed).
Care and Preventive Maintenance The Parker is subject to wear and tear, and the following actions must be performed when specified to ensure that the product remains within its original manufacturing specification WARNING To avoid malfunction resulting in injury, make sure to conduct regular inspections and follow the recommended maintenance schedule.
Page 45
WARNING To avoid injury and/or unsafe product, the maintenance activities must be carried out at the correct frequency by qualified personnel using correct tools, parts and knowledge of procedure. Qualified personnel must have documented training in maintenance of this device. Every Every Every...
Page 46
The shower handle can be replaced uids should be used in recommended con- without ArjoHuntleigh support. centrations. • If the shower stand on the Parker GB is Every week damaged, contact and ArjoHuntleigh tech- nician. • Visually check all exposed parts, especially where personal contact is made by either the •...
Page 48
Every month Yearly 1 Remove and clean the shower head: Parker has to be serviced according to the Care (See Fig. 1) and Preventive Maintenance Schedule (Qualified Personnel Action/Check). • Loosen the screw • Remove the parts according to the illustra- To make sure that you have a problem free and tion.
Troubleshooting NOTE If the problem can not be solved with the problem solving actions below, please contact an ArjoHuntleigh technician. PROBLEM ACTION Hand control does not work or control panel 1 Check that the emergency stop is not pressed buttons do not work and the green power down.
Page 51
PROBLEM ACTION Air Spa stops during operation. 1 Normal, if used more than 15 minutes. (option) 2 If used less than 15 minutes it may be over- heated due to high ambient temperature or clogged filter. Can be restarted when cooled off.
Technical Specifications TECHNICAL DATA General Tub length in the upright position 1855 mm / 73 inches Tub length in reclined position 1960 mm 77 1/8 inches Tub width 750 mm / 29 1/2 inches Height of door with bath in highest position, 2510 mm feet in lowest position 98 7/8 inches...
Page 53
IP Classification IP Class IP X4 IP Class hand control and Sound & Vision Hand control IP X7 Weight Parker depending on selected options (excluding packaging) 124 - 131 kg 273 - 289 lbs Recycling Package Wood and corrugated card-...
Page 54
SITE PREPARATION Floor Maximum floor load 450 kg / 0,8m Maximum floor pressure 0,6 N/mm Operating Conditions Max ambient temperature 10°C - 40°C (50°F -104° F) Max. relative humidity 30% - 95% Rh 800 hPa to 1060 hPa Atmospheric pressure range Transport and Storage Ambient temperature range -20°C - 70°C (-4°F - 158°F)
Page 55
WARNING To avoid electric shock, make sure that the equipment is connected to: • Continuously powered supply mains with protective earth. • Separate fuse and ground fault circuit interrupter (GFCI) • A mains disconnection device • Equipotential bonding point All installations must be in accordance with local codes and regulations. WATER SUPPLY Drain requirement Flow capacity...
Air Spa Duty Caution label Cycle Spa turned ON and OFF. States the potential hazard. Time span of lifting Parker Lift Duty Cycle and rest time. Calibration label The label is located on the control panel at Read IFU before use delivery.
Page 57
210 kg / 463 lbs 4 3/4" 300 kg / 661 lbs IP X4 Max Load Model Type : Parker Bath 500 CLASS I 300 kg / 661 lbs : 120V 60Hz Input Voltage Model Type : Parker Bath 500...
Approvals and List of Standards EN/ISO/IEC/UL 60601-1 Medical electrical equipment Part 1: General requirements for basic safety and essential per- formance. EN 60601-1-2 Electromagnetic Compatibility - Requirements and Tests CAN/CSA-C22.2 No. 601.1 Medical equipment Certified for Canada ANSI Z124. 1 Standards for Plastic Bathtub Units ANSI/ASME A112.19.7 Whirlpool Bathtub Appliances...
Guidance and manufacturer’s declaration – electromagnetic emissions The Parker is intended for use in the electromagnetic environment specified below. The customer or the user of the Parker should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
Page 60
Guidance and manufacturer’s declaration – electromagnetic immunity The Parker is intended for use in the electromagnetic environment specified below. The customer or the user of the Parker should assure that it is used in such an environment. Immunity test Compliance level...
Page 61
Guidance and manufacturer’s declaration – electromagnetic immunity Parker is intended for use in the electromagnetic environment specified below. The customer or the user of Parker should assure that it is used in such an environment. Immunity test Compli- ance Electromagnetic environment –...
Page 62
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which Parker is used exceeds the applicable RF compliance level above, the Parker should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Parker.
Parts and Accessories 400.00.00.02- Grey 400.00.00.09 - Grey 8257376-031 400.00.00.15 - Blue 400.00.00.16 - Blue Leg Rest Back Support Cushion Head Cushion For Disinfectant contact your local representative...
Page 67
AUSTRALIA FAR EAST POLSKA ArjoHuntleigh Pty Ltd ARJO Far East Limited ArjoHuntleigh Polska Sp. z o.o. 78, Forsyth street Unit 3A, 4/F., block B Hoi Luen ul. Ks Piotra Wawrzyniaka 2 O’Connor Industrial Centre PL 62-052 KOMORNIKI (Poznan) AU-6163 Western Australia...
Page 68
GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions.
Need help?
Do you have a question about the Parker and is the answer not in the manual?
Questions and answers