Preface We thank you for your decision to purchase a product by ArjoHuntleigh. Your ArjoHuntleigh bathing system is part of a series of quality products, which were developed especially for the optimal hygiene of residents and the economics of care taking facilities Your wish is our command.
Page 6
Definition: Safety instructions: if you do not understand or follow these instructions, you are placing yourself or other persons in danger. CAUTION! Meaning: This information is important for the correct use of this system or equipment. Instruction manual – Instructions for using the Classic Line bath Page 4...
Assembly and Installation Safety Precautions Assembly and installation: • only through qualified personnel • only according to the local regulations After assembly, the following must be verified: • All components were assembled per instructions. • All fasteners are securely tightened. •...
Plumbing Installation Water supply connection The scope of delivery of the bathtub includes the technical documentation/instructions of the shut off valve manufacturer, the information about the areas of application, technical data and notes on the installation. A shutoff valve and filters (mesh size: 0.5 mm) must be installed in the hot- and coldwater supply lines.
Electrical Installation Power supply connection All electrical installations must be performed by a certified electrician and must comply with all local electrical safety codes. See customer installation requirements sheet for technical details.* Prior to installation, verify that the power supply meets the rating specified on the type plate.
Automatic Filling of the Bathtub (Only with the automatic bathtub filling system option) Membrane key for basic automatic filling of the bathtub (about 24 cm). Pressing the key again stops the filling operation. A safety switch stops the water flow after 10 minutes After filling the bathtub, water can be refilled by pressing the operating button.
Product Liability • If modifications are made to the device without the explicit permission by ArjoHuntleigh, or if the equipment is not checked or maintained according to the instructions in the chapter “Maintenance Guidelines” and the checklist in this manual, all product liabilities shall be rendered null and void.
Signs The type plate contains the following information: • Product and serial number, Date of manufacture • Maximum safe working load: (total weight of the occupant and water) 400 kg • Maximum water pressure: 6 bar • 400 mm, the height of the bathtub can be electrically adjusted (HI-LO- SYSTEM) •...
Operation Safety Requirements Information contained in this manual is crucial for the proper operation and maintenance of this equipment. Information contained herein is important for your safety; therefore, it must be read and understood to avoid possible injuries. Should you have any questions or you do not understand parts of this manual, please contact our customer service department prior to the installation or operation of the bathtub.
Explanation of Components. General 1. The vertical and horizontal handholds ensure solid support and safety. 2. The 2- or 3- positional and adjustable footrest with handhold allows for four longitudinal settings. This ensures persons of various heights will always have a solid support in the bathtub by bracing their feet.
Instrument Panel with Temperature Display 1. The hand-held showerhead (1) is used to shower the resident/patient. 2. The hand valve (2) is used to regulate the water supply to the hand-held showerhead. The valve allows either shutting off or opening the water supply or adjusting the water flow.
If the bathtub is not equipped with a disinfecting device, the mandatory procedures and regulations for the disinfection of large areas of bathtubs should apply. In this case, use ArjoHuntleigh Clean, and follow the manufacturer’s instructions regarding dosage and reaction time.
Comfort music (optional) Volume control Music ON: Press briefly Music OFF: Press and hold for about 3 seconds Next track Previous track Light, optional Please note: If the bathtub is not equipped with Comfort Music, the has to be controlled using separate buttons on the bathtub! The casing can be unscrewed at the back side for changing the batteries.
Page 18
Coding: If there are several bathtubs with Comfort Music option under one roof, then there could be problems with the individual systems if the same coding is used. In this case, the coding of the Music system should be changed as follows: 1.
Page 19
USB – flash drive A splash-proof socket is integrated into the body of the bathtub for accommodating a USB flash drive (for the mp3 player). The LED of the USB drive flashes when music is being transferred. Data format for mp3 player (optional) The mp3 player works only with mp3 files saved with a specific bit rate.
Light (optional) Light operation if equipped with Comfort Music Switching on: The colour LED illumination starts with the first colour when the button is pressed. The LED illumination changes to the next colour if the button is pressed again. The colours change automatically after the button is pressed for the sixth time.
Care and Maintenance In addition to the daily cleansing and disinfection, the lift bathtub Classic Line should be visually inspected for damage. The tub is equipped with a maintenance-free motor. Repairs or replacement of defective fuses may only be performed by the manufacturer’s service department.
Checking the maximum temperature safeguard and limitation Checking and cleaning the shower heads Checking and cleaning the filter water supply Customer service authorized by ArjoHuntleigh Lubrication of moving parts Inspecting all important components for corrosion and damages Conducting a complete function test...
Troubleshooting Only qualified and authorized personnel should correct any failures or malfunctions of the plumbing and/or electrical system; otherwise, please contact the ArjoHuntleigh customer services department. SYMPTOM POSSIBLE REMEDY Thermostat mixer Only hot or cold water flows a) Check filters and inlet/outlet fittings for any obstruction. If necessary, from the mixing tap;...
Page 24
If required: Remove the USB flash drive, Disconnect power from the tub and wait for a minute. Then reconnect the power supply and insert the USB flash drive. If these tips do not solve the problem, or if there are still unanswered questions, please contact the ArjoHuntleigh customer service Page 22...
Initialisation of the Control System Caution: No person should use the bathtub for bathing during the initialization process. Ensure that the motors on both sides are lowered smoothly during the initialization; otherwise, the equipment may be damaged. The adjustment drives must be connected to the control system during the initialization process.
Accessories Calypso The lift bath trolley Calypso is vertically adjustable and especially suitable for the Arjo bathing and shower system. Using the Calypso, residents can be transported back and forth between bed and bath - without any effort and unnecessary movements.
Guidance and manufacturer´s declaration – electromagnetic emission The bathtub classic line is intended for use in the electromagnetic environment specified below. The customer or the user of the bathtub classic line should assure that it is used in such an environment. Emissions test...
Page 28
Guidance and manufacturer´s declaration – electromagnetic immunity The bathtub classic line is intended for use in the electromagnetic environment specified below. The customer or the user of the bathtub classic line should assure that it is used in such an environment. IEC 60601...
Page 29
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the bathtub classic line is used exceeds the applicable RF compliance level above, the bathtub classic line should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the bathtub classic line.
Page 30
RF communications equipment and the bathtub classic line The bathtub classic line is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the bathtub classic line can help prevent electromagnetic interference by...
Page 31
Free: +1 800 072 040 Fax: +33 (0) 3 20 28 13 14 POLSKA Fax: + 61 89337 9077 E-mail: info.france@arjohuntleigh.com ArjoHuntleigh Polska Sp. z o.o. BELGIQUE / BELGIË HONG KONG ul. Ks Piotra Wawrzyniaka 2 ArjoHuntleigh NV/SA ArjoHuntleigh (Hong Kong) Ltd...
Page 32
GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions. GETINGE provides solutions for infection control within healthcare and contamination prevention within life sciences.
Need help?
Do you have a question about the Classic Line and is the answer not in the manual?