Buffer Battery 12V 2,7Ah max:
It is possible to connect a buffer battery to make in work only
the Alarm system, also with electrical line missing. Moreover it
has An incorporated battery charger 13,8V (both for buffer
battery And the one in the alarm siren).
PROGRAMMING:
SEL button: selects the type of function to be memorised. The
selection is indicated by a flashing LED.
By repeatedly pressing the button it is possible to choose the
Desired function. The selection will remain active for 10
seconds indicated by a flashing LED. If no other operations are
executed during this period, the control board will return to its
previous state.
SET button: programs the information relative the type of
function previously selected with the SEL button.
IMPORTANT: the function of the SET button can also be
replaced With radio control if it was programmed before (led
CODE on).
MAIN MENU'
The electronic panel is supplied with the possibility to select
some important functions.
---------------------- MAIN MENU' -----------------
LED Reference
LED Off
1) CODE
No code
2) CODE ALARM
No code
3) LAMP./CORT.
Flashing Lamp
4) T. MOT.
Programmed 30''
5) T. PAUSA.
No automatic close
1) CODE: (Programming of radio controls)
Programming of radio control for frame:
The programming of transmission codes of radio control for the
Frame operation is done in the following way: push SEL button,
LED CODE starts lighting, in the meanwhile send the
transmission Code with the related radio control, at this point
the LED CODE will Stay on the programming will be completed.
Rule of the first memorized radio control:
In radio controls programming there is the following rule: if the
first Memorized radio control is a Rolling Code one, the
electronic panel will accept only Rolling Code radio controls,
with more anti-Intrusion safety; if instead the first memorized
radio control has fixed Code, the receiver will accept both fixed
codes and Rolling Code Radio controls.
Radio control already in memory or incompatible:
It is possible to memorize up to 120 radio controls with different
Codes. In case of programming devices already in memory or
Incompatible, the LED CODE starts flashing rapidly for some
instant, Flaging the impossibility and then it will return to
programming.
Highest number of memorized devices:
It is possible to memorize up to 120 radio controls with different
Codes. In case of the hightest number of memorized devices is
Reached, repeating the programming, the electronic panel
flags the Error by the flashing of all the leds save the LED
CODE, which stays Fixed on. After 10 seconds the electronic
panel exits from the Programming mode.
LED On
Device activated
Device activated
Courtesy Light
Programmed delay
With automatic close
2) CODE ALARM: (Programming of the radio control for the
Activation/deactivation of the alarm system ).
The method of programming and cancellation is similar to the
one Described before, but related to LED CODE ALARM, with
the only Difference that it is refered to a button, related to the
radio control for Activation and deactivation of the alarm
system.
Important: when any Alarm Code was not programmed (CODE
ALARM OFF), the panel does not control connections and
functions Of the Alarm System.
3) LAMP/CORT: (Selection of the flashing light or the courtesy
light).
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light. The control unit is supplied by
the manufacturer with the flashing function even with delay
enabled. If you wish to set up the flashing light function,
proceed as follows: use the SEL button to navigate to the
LAMP/CORT LED when flashing and then press the SET
button. The LAMP/CORT button will light up permanently.
Repeat the operation if you wish to put the previous
configuration Back into operation. If you wish to set up the
courtesy light, repeat The operation described above, pressing
the SEL button twice instead of once (the LAMP/CORT LED
will flash rapidly). Repeat the operation if you wish to put the
previous configuration back into Operation.
Flashing Light function even in pause: the 230 Vac output
will be Activated each time that the automation is moving, for
the duration of the motor time. If the pause time is memorised,
the 230Vac output will be active even during the delay.
Flashing function: The 230 Vac output will be activated each
time that the automation is moving, for the duration of the
motor time.
Functioning of the Courtesy light: The 230 Vac output will be
activated for 3 minutes, each time that an opening command is
Given.
Important: the flashing/Courtesy light will be activated at the
Same time with the Alarm System, till its switching off.
4) T. MOT. (Programming the motor operating time max. 4
Minutes).
The control unit is factory supplied with a predefined working
time motor equal to 30 sec. If a reprogramming of the motor
operating time is needed, it must be carried out through the
closed frame in the following manner: use the SEL button to
navigate to the T. MOT LED when flashing, then continuously
press the SET button. The rolling shutter will start the opening.
When you have reached the required height, release the SET
button and at the same time the motor time storage will be
completed and the T. MOT. LED will remain lit and fixed.
5) T. PAUSE:
(Maximum programmed automatic closing 4 minutes.)
The manufacturer furnishes the control unit with an automatic
closure (pause time equal to 15 sec.). If a reprogramming of
the automatic closing time is needed, it must be carried out
through the closed frame in the following manner: use the SEL
button to navigate to the T. PAUSE LED when flashing. Then
press and hold down the SET button for a period equal to the
Desired pause interval between closing and opening
operations. At expiration of the desired time release the SET
button. At the same time the memorisation of automatic closing
time will be determined and the T. PAUSE LED will remain lit.
If you do not want automatic closing, take position on the T.
PAUSE LED when flashing. Then press the SET button for less
than a second. At the same time the LED will shut off and the
operation will be concluded.